Real-time, 3-dimensional echocardiography acquires all standard 2-dimensional images from 2 volume sets: a clinical demonstration in 45 patients.

To test the hypothesis that real-time, 3-dimensional (3-D) echocardiography can obtain all standard 2-dimensional (2-D) views from acquisition of 2 volume sets, we scanned 45 patients (24 men, 21 women; mean age 49 +/- 17 years). This real-time 3-D device (VOLUMETRICS Medical Imaging, Durham, NC) uses a matrix phased array transducer in a 60 degree pyramidal volume. Images are displayed as 2 steerable, intersecting, conventional 2-D image sectors that can be oriented throughout 3-D space. By using this equipment, we were able to obtain 93.3% of standard views from a parasternal volume set and 85.2% of standard views from an apical volume set. The mean scanning time was 91 +/- 19 seconds for the parasternal volume set and 86 +/- 22 seconds for the apical volume set. We conclude that standard 2-D views can be obtained in the majority of patients by using this method. This equipment has the potential to substantially decrease the imaging time compared with the standard 2-D echocardiography.

[1]  T Akasaka,et al.  Assessment of flail mitral leaflets by dynamic three-dimensional echocardiographic imaging. , 1997, The American journal of cardiology.

[2]  N Hosten,et al.  Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass. , 1997, Heart.

[3]  R A Levine,et al.  Insights from three-dimensional echocardiography into the mechanism of functional mitral regurgitation: direct in vivo demonstration of altered leaflet tethering geometry. , 1997, Circulation.

[4]  D. King,et al.  Freehand three-dimensional echocardiography for measurement of left ventricular mass: in vivo anatomic validation using explanted human hearts. , 1997, Journal of the American College of Cardiology.

[5]  N G Pandian,et al.  Three-dimensional echocardiographic estimation of infarct mass based on quantification of dysfunctional left ventricular mass. , 1997, Circulation.

[6]  L M Boxt,et al.  Freehand three-dimensional echocardiography for determination of left ventricular volume and mass in patients with abnormal ventricles: comparison with magnetic resonance imaging. , 1997, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  J Deng,et al.  Fetal echocardiography in three and four dimensions. , 1996, Ultrasound in medicine & biology.

[8]  R. Pini,et al.  Transthoracic three-dimensional echocardiographic reconstruction of left and right ventricles: in vitro validation and comparison with magnetic resonance imaging. , 1997, American heart journal.

[9]  M. Spiecker,et al.  Quantitative assessment of aortic stenosis by three-dimensional echocardiography. , 1997, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.