GCaMP6 ΔF/F dependence on the excitation wavelength in 3-photon and 2-photon microscopy of mouse brain activity.

A fundamental challenge in calcium imaging is to minimize the excitation laser power while still maintaining a sufficient signal-to-noise ratio to distinguish individual transients in the fluorescence traces. It is important to characterize relative fluorescence (i.e., ΔF/F) dependence on the excitation wavelength in vivo where the environment cannot be controlled effectively during imaging. Leveraging time division multiplexing of two excitation beams to achieve nearly simultaneous 2-photon and 3-photon imaging of the calcium transients, we measured systematically the ΔF/F dependence on the excitation wavelength in 2-photon and 3-photon in vivo imaging of neuronal activity in mouse brain labeled with GCaMP6s. The technique can be applied to in vivo measurements of other fluorescence sensors.

[1]  Fraser T. Sparks,et al.  Volumetric Ca2+ Imaging in the Mouse Brain Using Hybrid Multiplexed Sculpted Light Microscopy , 2019, Cell.

[2]  Mark J Schnitzer,et al.  Three-Photon Imaging of Mouse Brain Structure and Function through the Intact Skull , 2018, Nature Methods.

[3]  Ziwei Zhuang,et al.  Measurement of 3-photon excitation and emission spectra and verification of Kasha's rule for selected fluorescent proteins excited at the 1700-nm window. , 2019, Optics express.

[4]  D. Tank,et al.  Imaging Large-Scale Neural Activity with Cellular Resolution in Awake, Mobile Mice , 2007, Neuron.

[5]  W. Denk,et al.  Two-photon laser scanning fluorescence microscopy. , 1990, Science.

[6]  W. Webb,et al.  Multiphoton fluorescence excitation: new spectral windows for biological nonlinear microscopy. , 1996, Proceedings of the National Academy of Sciences of the United States of America.

[7]  R. Yuste,et al.  Detecting action potentials in neuronal populations with calcium imaging. , 1999, Methods.

[8]  Andreas S Tolias,et al.  In vivo three-photon imaging of activity of GCaMP6-labeled neurons deep in intact mouse brain , 2017, Nature Methods.

[9]  Weijian Yang,et al.  In vivo imaging of neural activity , 2017, Nature Methods.

[10]  Bo Li,et al.  Comparing the effective attenuation lengths for long wavelength in vivo imaging of the mouse brain. , 2018, Biomedical optics express.

[11]  Stefan R. Pulver,et al.  Ultra-sensitive fluorescent proteins for imaging neuronal activity , 2013, Nature.

[12]  W. Denk,et al.  Imaging in vivo: watching the brain in action , 2008, Nature Reviews Neuroscience.

[13]  A. Gordus,et al.  Sensitive red protein calcium indicators for imaging neural activity , 2016, bioRxiv.

[14]  Zachary F. Mainen,et al.  The Functional Microarchitecture of the Mouse Barrel Cortex , 2007, PLoS Biology.

[15]  Lin Tian,et al.  Functional imaging of hippocampal place cells at cellular resolution during virtual navigation , 2010, Nature Neuroscience.

[16]  James E. Fitzgerald,et al.  Photon shot noise limits on optical detection of neuronal spikes and estimation of spike timing. , 2013, Biophysical journal.

[17]  Christine Grienberger,et al.  Imaging Calcium in Neurons , 2012, Neuron.

[18]  C. Stosiek,et al.  In vivo two-photon calcium imaging of neuronal networks , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[19]  W. Webb,et al.  Nonlinear magic: multiphoton microscopy in the biosciences , 2003, Nature Biotechnology.

[20]  F. Wise,et al.  In vivo three-photon microscopy of subcortical structures within an intact mouse brain , 2012, Nature Photonics.

[21]  Andreas T. Schaefer,et al.  Two-photon calcium imaging of evoked activity from L5 somatosensory neurons in vivo , 2011, Nature Neuroscience.

[22]  Mikhail Drobizhev,et al.  Deciphering the molecular mechanism responsible for GCaMP6m's Ca2+-dependent change in fluorescence , 2017, PloS one.