Effects of Inertia and Wrist Oscillations on Contralateral Neurological Postural Tremor Using the Wristalyzer, a New Myohaptic Device

Upper limb postural tremor consists of mechanical-reflex and central-neurogenic oscillations, superimposed upon a background of irregular fluctuations in muscle force. Muscle spindles play key-roles in the information flow to supra-spinal and spinal generators. Oscillations were delivered using a new generation portable myohaptic device, called ldquowristalyzer,rdquo taking into account the ergonomy of upper limbs and allowing a fine adjustment to each configuration of upper limb segments. The nominal torque of the first generation device is 4 Nm, with a maximal rotation velocity of 300 degrees/s and a range of motion of plusmn45 degrees. Reliability was assessed in basal condition and during loading conditions. We assessed the effects of the addition of inertia on postural tremor of the finger in a group of 26 neurological patients and the effects of wrist oscillations upon contralateral postural tremor in 6 control subjects and in 7 neurological patients exhibiting a postural tremor. Patients showed two different behaviors in response to inertia and exhibited an increased variability of postural tremor during fast oscillations (13.3 Hz). One patient with overactivity of the olivocerebellar pathways exhibited a drop in the peak frequency of more than 20%. The relative power of the 8-12 Hz subband was significantly higher in controls both in basal condition and during oscillations (p = 0.028 and p = 0.015, respectively). The second generation wristalyzer allows to investigate the effects of mechanical oscillations up to frequency of 50 Hz. This mechatronic device can assess the responsiveness of tremor generators to stimulation of muscle spindles and biomechanical loading. Potential applications are the monitoring of dysmetria under various inertial or damping conditions, the assessment of rigidity in Parkinson's disease and the characterization of voluntary muscle force.

[1]  RICHARD ALLEN CHASE,et al.  Modification of Intention Tremor in Man , 1965, Nature.

[2]  R. N. Stiles Mechanical and neural feedback factors in postural hand tremor of normal subjects. , 1980, Journal of neurophysiology.

[3]  M. Manto,et al.  Effects of wrist oscillations on contralateral neurological postural tremor using a new myohaptic device ('wristalyzer') , 2007, 2007 4th IEEE/EMBS International Summer School and Symposium on Medical Devices and Biosensors.

[4]  F Bruyninckx,et al.  Motor unit synchronization in physiologic, enhanced physiologic, and voluntary tremor in man , 1988, Annals of neurology.

[5]  J F Wilson,et al.  The tremorolytic action of beta-adrenoceptor blockers in essential, physiological and isoprenaline-induced tremor is mediated by beta-adrenoceptors located in a deep peripheral compartment. , 1985, British journal of clinical pharmacology.

[6]  S. Swinnen,et al.  Online movement control in multiple sclerosis patients with tremor: Effects of tendon vibration , 2006, Movement disorders : official journal of the Movement Disorder Society.

[7]  Umberto Castiello,et al.  The bilateral reach to grasp movement , 1993, Behavioural Brain Research.

[8]  R. Elble Central mechanisms of tremor. , 1996, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[9]  Eduardo Rocon,et al.  Mechanical suppression of essential tremor , 2008, The Cerebellum.

[10]  J. Schulz,et al.  Long-term EMG recordings differentiate between parkinsonian and essential tremor , 2008, Journal of Neurology.

[11]  Giselher Schalow Tremor in Parkinson's disease patients can be induced by uncontrolled activation and uninhibited synchronization of alpha2-motoneuron firing to which alpha1-motoneuron firing synchronizes. , 2005, Electromyography and clinical neurophysiology.

[12]  A. Lang,et al.  The cerebellothalamocortical pathway in essential tremor , 2003, Neurology.

[13]  H. Shill,et al.  Corticomuscular coherence is increased in the small postural tremor of Parkinson's disease , 2006, Movement disorders : official journal of the Movement Disorder Society.

[14]  S. Schneider,et al.  Familial dopa-responsive cervical dystonia , 2006, Neurology.

[15]  M Steffin,et al.  Virtual reality therapy of multiple sclerosis and spinal cord injury: design consideration for a haptic-visual interface. , 1997, Studies in health technology and informatics.

[16]  D. Reinkensmeyer,et al.  A bimanual reflex during two hand grasp , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[17]  Karl M Newell,et al.  Amplitude changes in the 8–12, 20–25, and 40 Hz oscillations in finger tremor , 2000, Clinical Neurophysiology.

[18]  D M Wolpert,et al.  Multiple paired forward and inverse models for motor control , 1998, Neural Networks.

[19]  Karen Marder,et al.  Diagnosing Parkinson's disease using videotaped neurological examinations: Validity and factors that contribute to incorrect diagnoses , 2002, Movement disorders : official journal of the Movement Disorder Society.

[20]  P. O'Suilleabhain,et al.  Validation for tremor quantification of an electromagnetic tracking device , 2001, Movement disorders : official journal of the Movement Disorder Society.

[21]  E. Rocon,et al.  Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[22]  T. Zhang,et al.  Quantitative assessment of Parkinson's disease deficits. , 1999, Chinese medical journal.

[23]  M J Rosen,et al.  A wearable tremor-suppression orthosis. , 1998, Journal of rehabilitation research and development.

[24]  J. Hubble,et al.  Essential tremor. , 1989, Clinical neuropharmacology.

[25]  R. Elble Characteristics of physiologic tremor in young and elderly adults , 2003, Clinical Neurophysiology.

[26]  C. Marsden,et al.  Tremor associated with benign IgM paraproteinaemic neuropathy. , 1996, Brain : a journal of neurology.

[27]  R. Grünewald,et al.  Abnormal vibration induced illusion of movement in essential tremor: evidence for abnormal muscle spindle afferent function , 2004, Journal of Neurology, Neurosurgery & Psychiatry.

[28]  E D Louis,et al.  A teaching videotape for the assessment of essential tremor , 2001, Movement disorders : official journal of the Movement Disorder Society.

[29]  Simon A. Neild,et al.  Estimation of Upper-Limb Orientation Based on Accelerometer and Gyroscope Measurements , 2008, IEEE Transactions on Biomedical Engineering.

[30]  W Z Rymer,et al.  Damping actions of the neuromuscular system with inertial loads: soleus muscle of the decerebrate cat. , 2000, Journal of neurophysiology.

[31]  Wai Yin Wong,et al.  Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review , 2007, Prosthetics and orthotics international.

[32]  R. Elble,et al.  Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor. , 1976, Journal of neurophysiology.

[33]  Jos Meuleman,et al.  A New Myohaptic Device to Assess Wrist Function in the Lab and in the Clinic - The Wristalyzer , 2008, EuroHaptics.

[34]  P Hahn,et al.  Does an Ulnar Nerve Lesion Influence the Motion of the Index Finger? , 1996, Journal of hand surgery.

[35]  G. Deuschl,et al.  Tremor analysis in two normal cohorts , 2004, Clinical Neurophysiology.

[36]  Eduardo Rocon,et al.  Evaluation of a wearable orthosis and an associated algorithm for tremor suppression , 2007, Physiological measurement.

[37]  J. R. Bloedel,et al.  Adaptation of reach-to-grasp movement in response to force perturbations , 2003, Experimental Brain Research.