Comparison of CT-derived ventilation maps with deposition patterns of inhaled microspheres in rats

ABSTRACT Purpose: Computer models for inhalation toxicology and drug-aerosol delivery studies rely on ventilation pattern inputs for predictions of particle deposition and vapor uptake. However, changes in lung mechanics due to disease can impact airflow dynamics and model results. It has been demonstrated that non-invasive, in vivo, 4DCT imaging (3D imaging at multiple time points in the breathing cycle) can be used to map heterogeneities in ventilation patterns under healthy and disease conditions. The purpose of this study was to validate ventilation patterns measured from CT imaging by exposing the same rats to an aerosol of fluorescent microspheres (FMS) and examining particle deposition patterns using cryomicrotome imaging. Materials and Methods: Six male Sprague-Dawley rats were intratracheally instilled with elastase to a single lobe to induce a heterogeneous disease. After four weeks, rats were imaged over the breathing cycle by CT then immediately exposed to an aerosol of ∼1μm FMS for ∼5 minutes. After the exposure, the lungs were excised and prepared for cryomicrotome imaging, where a 3D image of FMS deposition was acquired using serial sectioning. Cryomicrotome images were spatially registered to match the live CT images to facilitate direct quantitative comparisons of FMS signal intensity with the CT-based ventilation maps. Results: Comparisons of fractional ventilation in contiguous, non-overlapping, 3D regions between CT-based ventilation maps and FMS images showed strong correlations in fractional ventilation (r = 0.888, p < 0.0001). Conclusion: We conclude that ventilation maps derived from CT imaging are predictive of the 1μm aerosol deposition used in ventilation-perfusion heterogeneity inhalation studies.

[1]  Brian B. Avants,et al.  Explicit B-spline regularization in diffeomorphic image registration , 2013, Front. Neuroinform..

[2]  Neil Woodhouse,et al.  Emphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI. , 2005, European journal of radiology.

[3]  R. Rizi,et al.  Imaging physiological parameters with hyperpolarized gas MRI , 2005 .

[4]  F. J. Miller,et al.  Development of a rhesus monkey lung geometry model and application to particle deposition in comparison to humans , 2012, Inhalation toxicology.

[5]  Wolfgang A. Wall,et al.  Towards a comprehensive computational model for the respiratory system , 2010 .

[6]  Yaoqin Xie,et al.  Nonrigid Registration of Lung CT Images Based on Tissue Features , 2013, Comput. Math. Methods Medicine.

[7]  Marianne Geiser,et al.  Influence of surface chemistry and topography of particles on their immersion into the lung's surface-lining layer. , 2003, Journal of applied physiology.

[8]  Richard E. Jacob,et al.  Stable Small Animal Ventilation for Dynamic Lung Imaging to Support Computational Fluid Dynamics Models , 2011, PloS one.

[9]  Eric A. Hoffman,et al.  Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation , 2008, Medical Image Anal..

[10]  Paul J Keall,et al.  Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using 68Ga-labeled nanoparticles. , 2013, Medical physics.

[11]  Kevin R Minard,et al.  Comparative computational modeling of airflows and vapor dosimetry in the respiratory tracts of rat, monkey, and human. , 2012, Toxicological sciences : an official journal of the Society of Toxicology.

[12]  Arno Klein,et al.  A reproducible evaluation of ANTs similarity metric performance in brain image registration , 2011, NeuroImage.

[13]  J. R. Ewen,et al.  High spatial resolution measurements of organ blood flow in small laboratory animals. , 2000, American journal of physiology. Heart and circulatory physiology.

[14]  O. Price,et al.  Computational fluid dynamics simulations of inhaled nano- and microparticle deposition in the rhesus monkey nasal passages , 2013, Inhalation toxicology.

[15]  Youbing Yin,et al.  MDCT-based dynamic, subject-specific lung models via image registration for CFD-based interrogation of regional lung function , 2011 .

[16]  Jiwoong Choi,et al.  Simulation of pulmonary air flow with a subject-specific boundary condition. , 2010, Journal of biomechanics.

[17]  J. Carson,et al.  Detecting radiation-induced injury using rapid 3D variogram analysis of CT images of rat lungs. , 2013, Academic radiology.

[18]  Robb W Glenny,et al.  High-resolution spatial measurements of ventilation-perfusion heterogeneity in rats. , 2010, Journal of applied physiology.

[19]  M. Cosio,et al.  Animal models of chronic obstructive pulmonary disease. , 2008, American journal of physiology. Lung cellular and molecular physiology.

[20]  Gary E. Christensen,et al.  Reproducibility of registration-based measures of lung tissue expansion. , 2012, Medical physics.

[21]  D. Klee,et al.  Influence of particle size and material properties on mucociliary clearance from the airways. , 2010, Journal of aerosol medicine and pulmonary drug delivery.

[22]  Thomas Guerrero,et al.  Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis , 2012, Physics in medicine and biology.

[23]  J. Godleski,et al.  Emphysema alters the deposition pattern of inhaled particles in hamsters. , 1987, The American journal of pathology.

[24]  A. Kuprat,et al.  Phase-contrast MRI and CFD modeling of apparent ³He gas flow in rat pulmonary airways. , 2012, Journal of magnetic resonance.

[25]  Thomas Guerrero,et al.  Ventilation from four-dimensional computed tomography: density versus Jacobian methods , 2010, Physics in medicine and biology.

[26]  Thomas Guerrero,et al.  Novel method to calculate pulmonary compliance images in rodents from computed tomography acquired at constant pressures , 2006, Physics in medicine and biology.

[27]  Jeffry D Schroeter,et al.  A computational fluid dynamics approach to assess interhuman variability in hydrogen sulfide nasal dosimetry , 2010, Inhalation toxicology.

[28]  Mathew Thomas,et al.  Dynamic Multiscale Boundary Conditions for 4D CT of Healthy and Emphysematous Rats , 2013, PloS one.

[29]  Thomas Guerrero,et al.  Hyperpolarized (3)He magnetic resonance imaging: comparison with four-dimensional x-ray computed tomography imaging in lung cancer. , 2012, Academic radiology.

[30]  A. Rostami,et al.  Computational modeling of aerosol deposition in respiratory tract: a review. , 2009, Inhalation toxicology.

[31]  Brian B. Avants,et al.  Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain , 2008, Medical Image Anal..

[32]  James P. Carson,et al.  Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition , 2014, BMC Medical Imaging.

[33]  J. Butler,et al.  Chaotic mixing deep in the lung , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[34]  M. Scadeng,et al.  MRI-based measurements of aerosol deposition in the lung of healthy and elastase-treated rats , 2014, Journal of applied physiology.

[35]  Wei Yang,et al.  Inhaled nanoparticles--a current review. , 2008, International journal of pharmaceutics.

[36]  Eric A Hoffman,et al.  CT-measured regional specific volume change reflects regional ventilation in supine sheep. , 2008, Journal of applied physiology.

[37]  M. Krueger,et al.  Heterogeneity and matching of ventilation and perfusion within anatomical lung units in rats , 2013, Respiratory Physiology & Neurobiology.

[38]  Cristian Lorenz,et al.  4D CT lung ventilation images are affected by the 4D CT sorting method. , 2013, Medical physics.

[39]  Jesús Ruiz-Cabello,et al.  Dynamic Ventilation $^3$He MRI for the Quantification of Disease in the Rat Lung , 2012, IEEE Transactions on Biomedical Engineering.

[40]  Kai Ding,et al.  Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT. , 2012, Medical physics.