Measuring protein-protein interactions using Biacore.

The use of optical biosensors for studying macromolecular interactions is gaining increasing popularity. In one study, 1,179 papers that involved the application of biosensor data were identified for the year 2007 alone (Rich and Myszka, J Mol Recognit 21:355-400, 2008), the sheer volume and variety of which present a daunting task for the burgeoning biosensor user to accumulate and decipher. This chapter is designed to provide the reader with the tools necessary to prepare, design, and efficiently execute a kinetic experiment on Biacore. It is written to guide the Biacore user through basic theory, system maintenance, and assay set-up while also offering some practical tips that we find useful for Biacore-based studies. Many kinetic-based screening assays require rigorous sample preparation and purification prior to analysis. To highlight these procedures, this protocol describes the kinetic characterisation of single chain Fv (scFv) antibody fragments from crude bacterial lysates using an antibody affinity capture approach. Even though we specifically describe the capture of HA-tagged scFv antibody fragments to an anti-HA tag monoclonal antibody-immobilised surface prior to kinetic analysis, the same methodologies are universally applicable and can be used for practically any affinity pair and most Biacore systems.

[1]  Richard O'Kennedy,et al.  Immunoassay for the determination of morphine-3-glucuronide using a surface plasmon resonance-based biosensor. , 2003, Biosensors & bioelectronics.

[2]  R. O'Kennedy,et al.  Overcoming antibody expression and screening limitations by smart design: applications to PSA immunoassay development. , 2012, Protein expression and purification.

[3]  P. Conroy,et al.  Surface plasmon resonance for vaccine design and efficacy studies: recent applications and future trends , 2010, Expert review of vaccines.

[4]  Yun Hee Cho,et al.  Comparative analysis of 10 small molecules binding to carbonic anhydrase II by different investigators using Biacore technology. , 2006, Analytical biochemistry.

[5]  Paul Leonard,et al.  Development of a surface plasmon resonance-based immunoassay for Listeria monocytogenes. , 2005, Journal of food protection.

[6]  Richard O'Kennedy,et al.  Production, purification and characterisation of genetically derived scFv and bifunctional antibody fragments capable of detecting illicit drug residues. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[7]  David G Myszka,et al.  Characterizing high-affinity antigen/antibody complexes by kinetic- and equilibrium-based methods. , 2004, Analytical biochemistry.

[8]  Paul Leonard,et al.  Antibody production, design and use for biosensor-based applications. , 2009, Seminars in cell & developmental biology.

[9]  Mingde Zhu,et al.  Kinetic analysis of a high-affinity antibody/antigen interaction performed by multiple Biacore users. , 2006, Analytical biochemistry.

[10]  Rebecca L Rich,et al.  Survey of the 2009 commercial optical biosensor literature , 2011, Journal of molecular recognition : JMR.

[11]  D G Myszka,et al.  Survey of the 1998 optical biosensor literature , 1999, Journal of molecular recognition : JMR.

[12]  R. Rich,et al.  Survey of the 1999 surface plasmon resonance biosensor literature , 2000, Journal of molecular recognition : JMR.

[13]  J. Bruno,et al.  Overview of Biacore Systems and Their Applications , 2006, Current protocols in protein science.

[14]  Paul Leonard,et al.  Production, characterisation and potential application of a novel monoclonal antibody for rapid identification of virulent Listeria monocytogenes. , 2006, Journal of microbiological methods.

[15]  A. Rasooly,et al.  Surface plasmon resonance analysis of staphylococcal enterotoxin B in food. , 2001, Journal of food protection.

[16]  E. Giralt,et al.  Surface plasmon resonance screening of synthetic peptides mimicking the immunodominant region of C-S8c1 foot-and-mouth disease virus. , 1999, Vaccine.

[17]  D. Andreu,et al.  Direct kinetic assay of interactions between small peptides and immobilized antibodies using a surface plasmon resonance biosensor. , 2002, Journal of immunological methods.

[18]  J. Bruno,et al.  Using Biacore to Measure the Binding Kinetics of an Antibody‐Antigen Interaction , 2006, Current protocols in protein science.

[19]  C. Josenhans,et al.  Helicobacter pylori lipopolysaccharide interacts with TFF1 in a pH-dependent manner. , 2008, Gastroenterology.

[20]  Andrew Baxter,et al.  Rapid analysis of coumarins using surface plasmon resonance. , 2006, Journal of AOAC International.

[21]  D. Diamond,et al.  Development and application of surface plasmon resonance-based biosensors for the detection of cell-ligand interactions. , 2000, Analytical biochemistry.

[22]  Paul Leonard,et al.  A generic approach for the detection of whole Listeria monocytogenes cells in contaminated samples using surface plasmon resonance. , 2004, Biosensors & bioelectronics.

[23]  R. Rich,et al.  Survey of the year 2004 commercial optical biosensor literature , 2005, Journal of molecular recognition : JMR.

[24]  D. Myszka Kinetic, equilibrium, and thermodynamic analysis of macromolecular interactions with BIACORE. , 2000, Methods in enzymology.

[25]  R. Karlsson,et al.  Affinity measurement using surface plasmon resonance. , 2004, Methods in molecular biology.

[26]  Richard O'Kennedy,et al.  The development and application of a surface plasmon resonance-based inhibition immunoassay for the determination of warfarin in plasma ultrafiltrate. , 2004, Journal of immunological methods.

[27]  David G Myszka,et al.  Kinetic screening of antibodies from crude hybridoma samples using Biacore. , 2004, Analytical biochemistry.

[28]  J. Quinn,et al.  The use of regenerable, affinity ligand-based surfaces for immunosensor applications. , 1999, Biosensors & bioelectronics.

[29]  Paul Leonard,et al.  High throughput ranking of recombinant avian scFv antibody fragments from crude lysates using the Biacore A100. , 2007, Journal of immunological methods.

[30]  David G Myszka,et al.  Screening antibody-antigen interactions in parallel using Biacore A100. , 2006, Analytical biochemistry.

[31]  K. Andersson,et al.  Kinetic determinations of molecular interactions using Biacore—minimum data requirements for efficient experimental design , 2005, Journal of molecular recognition : JMR.

[32]  P. Katsamba,et al.  Analyzing a kinetic titration series using affinity biosensors. , 2006, Analytical biochemistry.

[33]  D. Myszka,et al.  Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors. , 1997, Current opinion in biotechnology.

[34]  Tiffany Tsang,et al.  Thermodynamic benchmark study using Biacore technology. , 2007, Analytical biochemistry.

[35]  D. Myszka,et al.  Improving biosensor analysis , 1999, Journal of molecular recognition : JMR.

[36]  M. Smyth,et al.  Detection of blood group antigens utilising immobilised antibodies and surface plasmon resonance. , 1997, Journal of immunological methods.

[37]  Paul Leonard,et al.  Novel assay format permitting the prolonged use of regeneration-based sensor chip technology. , 2005, Journal of immunological methods.

[38]  Helena Nordin,et al.  High-resolution characterization of antibody fragment/antigen interactions using Biacore T100. , 2006, Analytical biochemistry.

[39]  Richard O'Kennedy,et al.  Production of a recombinant anti-morphine-3-glucuronide single-chain variable fragment (scFv) antibody for the development of a "real-time" biosensor-based immunoassay. , 2003, Journal of immunological methods.

[40]  M. Morgan,et al.  Development of surface plasmon resonance-based immunoassay for aflatoxin B(1). , 2000, Journal of agricultural and food chemistry.

[41]  Paul Leonard,et al.  Detection of fungal spores using a generic surface plasmon resonance immunoassay. , 2007, Biosensors & bioelectronics.

[42]  P. J. Conroy,et al.  Cardiac troponin I: a case study in rational antibody design for human diagnostics. , 2012, Protein engineering, design & selection : PEDS.

[43]  Rebecca L Rich,et al.  A survey of the year 2002 commercial optical biosensor literature , 2003, Journal of molecular recognition : JMR.