The contrast‐to‐noise in relaxation time, synthetic, and weighted‐sum MR images

The contrast‐to‐noise ratio (CNR) in three types of computed MR images is compared in a computer simulation. The original data consist of two spin‐echo or two saturationrecovery images. Each pair of images is used to generate a relaxation time image, a synthetic image at arbitrary echo or repetition time, and an image which is a weighted sum of the original images. The CNR produced by these three methods is compared for signals spanning a wide range of relaxation times. In every comparison an optimally weighted sum produces the highest CNR that is statistically attainable. The CNR in the optimum synthetic image equals this bound only if contrast reversal does not occur in the original images. The CNR in relaxation time images is always less than the statistical bound and can be less than the CNR in the original images. © 1987 Academic Press, Inc.

[1]  L Kaufman,et al.  Analytical tools for magnetic resonance imaging. , 1984, Radiology.

[2]  Mischa Schwartz,et al.  Information transmission, modulation, and noise , 1959 .

[3]  P. Mansfield,et al.  SCIENTIFIC NOTE: A line scan image study of a tumorous rat leg by NMR , 1978 .

[4]  J N Lee,et al.  Automated MR image synthesis: feasibility studies. , 1984, Radiology.

[5]  P A Bottomley,et al.  Signal, Noise, and Contrast in Nuclear Magnetic Resonance (NMR) Imaging , 1983, Journal of computer assisted tomography.

[6]  J N Lee,et al.  A modified saturation‐recovery approximation for multiple spin‐echo pulse sequences , 1986, Magnetic resonance in medicine.

[7]  J N Lee,et al.  The precision of TR extrapolation in magnetic resonance image synthesis. , 1986, Medical physics.

[8]  A. Haase,et al.  Rapid NMR imaging of dynamic processes using the FLASII technique , 1986, Magnetic resonance in medicine.

[9]  J R MacFall,et al.  An analysis of noise propagation in computed T2, pseudodensity, and synthetic spin-echo images. , 1986, Medical physics.

[10]  N M Hylton,et al.  Signal to Noise in Derived NMR Images , 1984, Magnetic resonance in medicine.

[11]  D. O. North,et al.  An Analysis of the factors which determine signal/noise discrimination in pulsed-carrier systems , 1963 .

[12]  J N Lee,et al.  Optimum acquisition times of two spin echoes for MR image synthesis , 1986, Magnetic resonance in medicine.

[13]  W. Edelstein,et al.  Spin warp NMR imaging and applications to human whole-body imaging. , 1980, Physics in medicine and biology.

[14]  R. Kurland Strategies and tactics in NMR imaging relaxation time measurements. I. Minimizing relaxation time errors due to image noise—the ideal case , 1985, Magnetic resonance in medicine.