Influence of measurement noise and electrode mislocalisation on EEG dipole-source localisation

Measurement noise in the electro-encephalogram (EEG) and inaccurate formation about the locations of the EEG electrodes on the head induce localisation errors in the results of EEG dipole source analysis. These errors are studied by performing dipole source localisation for simulated electrode potentials in a spherical head model, for a range of different dipole locations and for two different numbers (27 and 148) of electrodes. Dipole source localisation is performed by iteratively minimising the residual energy (RE), using the simplex algorithm. The ratio of the dipole localisation error (cm) to the noise level (%) of Gaussian measurement noise amounts to 0.15 cm/% and 0.047 cm/% for the 27 and 148 electrode configurations, respectively, for a radial dipole with 40% eccentricity The localisation error due to noise can be reduced by taking into account multiple time instants of the measured potentials. In the case of random displacements of the EEG electrodes, the ratio of dipole localisation errors to electrode location errors amounts to 0.78 cm−1 cm and 0.27 cm−1 cm for the 27 and 148 electrode configurations, respectively. It is concluded that it is important to reduce the measurement noise, and particularly the electrode mislocalisation, as the influence of the latter is not reduced by taking into account multiple time instants.

[1]  J Gotman,et al.  Reliability of dipole models of epileptic spikes , 1999, Clinical Neurophysiology.

[2]  R.J. Maciunas,et al.  An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head , 1996, IEEE Transactions on Biomedical Engineering.

[3]  B. N. Cuffin,et al.  A method for localizing EEG sources in realistic head models , 1995, IEEE Transactions on Biomedical Engineering.

[4]  John A. Nelder,et al.  A Simplex Method for Function Minimization , 1965, Comput. J..

[5]  C. Adam,et al.  Dipole Modeling in Epilepsy Surgery Candidates , 1997, Epilepsia.

[6]  Dietrich Lehmann,et al.  Evaluation of Methods for Three-Dimensional Localization of Electrical Sources in the Human Brain , 1978, IEEE Transactions on Biomedical Engineering.

[7]  M. Fuchs,et al.  An improved boundary element method for realistic volume-conductor modeling , 1998, IEEE Transactions on Biomedical Engineering.

[8]  K. Sekihara,et al.  Relationship between dipole parameter estimation errors and measurement conditions in magnetoencephalography , 1993, IEEE Transactions on Biomedical Engineering.

[9]  John S. Ebersole,et al.  Spike voltage topography and equivalent dipole localization in complex partial epilepsy , 2005, Brain Topography.

[10]  David B. Geselowitz,et al.  Accuracy of Dipole Localization with a Spherical Homogeneous Model , 1983, IEEE Transactions on Biomedical Engineering.

[11]  P. Boon,et al.  Interictal and ictal dipole modelling in patients with refractory partial epilepsy , 1995, Acta neurologica Scandinavica.

[12]  W. Shankle,et al.  Approximating dipoles from human EEG activity: the effect of dipole source configuration on dipolarity using single dipole models , 1999, IEEE Transactions on Biomedical Engineering.

[13]  L Lemieux,et al.  Calculation of electrical potentials on the surface of a realistic head model by finite differences. , 1996, Physics in medicine and biology.

[14]  M. Scherg,et al.  Evoked dipole source potentials of the human auditory cortex. , 1986, Electroencephalography and clinical neurophysiology.

[15]  Deepak Khosla,et al.  Spatial mislocalization of EEG electrodes – effects on accuracy of dipole estimation , 1999, Clinical Neurophysiology.

[16]  J R Hughes The Significance of the Interictal Spike Discharge: A Review , 1989, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[17]  A. Achim Cerebral Source Localization Paradigms - Spatiotemporal Source Modeling , 1995, Brain and Cognition.

[18]  F. H. Lopes da Silva,et al.  Event-related potentials: methodology and quantification , 1998 .

[19]  M Wagner,et al.  Improving source reconstructions by combining bioelectric and biomagnetic data. , 1998, Electroencephalography and clinical neurophysiology.

[20]  D. Geselowitz On bioelectric potentials in an inhomogeneous volume conductor. , 1967, Biophysical journal.

[21]  Petre Stoica,et al.  MUSIC, maximum likelihood and Cramer-Rao bound: further results and comparisons , 1989, International Conference on Acoustics, Speech, and Signal Processing,.

[22]  M. E. Spencer,et al.  Error bounds for EEG and MEG dipole source localization. , 1993, Electroencephalography and clinical neurophysiology.

[23]  B. N. Cuffin,et al.  A Comparison of Moving Dipole Inverse Solutions Using EEG's and MEG's , 1985, IEEE Transactions on Biomedical Engineering.

[24]  J Malmivuo,et al.  Segmentation of T1 MR scans for reconstruction of resistive head models. , 1997, Computer methods and programs in biomedicine.

[25]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[26]  M. Scherg Fundamentals if dipole source potential analysis , 1990 .

[27]  Audra E. Kosh,et al.  Linear Algebra and its Applications , 1992 .

[28]  William H. Press,et al.  Numerical recipes in C. The art of scientific computing , 1987 .

[29]  R. Ilmoniemi,et al.  Interpreting magnetic fields of the brain: minimum norm estimates , 2006, Medical and Biological Engineering and Computing.

[30]  F Takeuchi,et al.  Locating accuracy of a current source of neuromagnetic responses: simulation study for a single current dipole in a spherical conductor. , 1989, Electroencephalography and clinical neurophysiology.

[31]  K. K. Tan,et al.  The spatial location of EEG electrodes: locating the best-fitting sphere relative to cortical anatomy. , 1993, Electroencephalography and clinical neurophysiology.

[32]  R. Fisher,et al.  Epileptic seizure disorders , 1985, Journal of Neurology.

[33]  Bart Vanrumste,et al.  The accuracy of the finite difference method applied in the forward problem of EEG source analysis , 1998 .

[34]  P Boon True versus standard international 10-20 EEG electrode positions and the spherical head model , 1997 .

[35]  B. Neil Cuffin,et al.  Effects of Measurement Errors and Noise on MEG Moving Dipole Inverse Solutions , 1986, IEEE Transactions on Biomedical Engineering.

[36]  Robert Plonsey,et al.  Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields , 1995 .

[37]  Cees J. Stok,et al.  The influence of model parameters on EEG/MEG single dipole source estimation , 1987, IEEE Transactions on Biomedical Engineering.

[38]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[39]  D. Wilton,et al.  Computational aspects of finite element modeling in EEG source localization , 1997, IEEE Transactions on Biomedical Engineering.

[40]  H. Jasper Report of the committee on methods of clinical examination in electroencephalography , 1958 .

[41]  M. Hallett,et al.  An improved method for localizing electric brain dipoles , 1990, IEEE Transactions on Biomedical Engineering.

[42]  J.C. Mosher,et al.  Multiple dipole modeling and localization from spatio-temporal MEG data , 1992, IEEE Transactions on Biomedical Engineering.

[43]  M Wagner,et al.  Inverse localization of electric dipole current sources in finite element models of the human head. , 1997, Electroencephalography and clinical neurophysiology.