A resonant cavity based on birdcage coil for overhauser geomagnetic sensor

The resonant cavity is an important component of Overhauser magnetometer sensor. Its function is to make the working substance generate dynamic nuclear polarization effect in the sensor. An alternative design of resonant cavity based on the birdcage coil structure was proposed to make the resonant frequency in accordance with the polarization frequency of the working substance. The structure and equivalent circuit of resonant cavity were analyzed. The model of resonant cavity was established and S-parameter is calculated to verify the frequency consistency of the resonant cavity and working substance. In addition, output signal experiment and simultaneous comparison testing of sensor prototype were conducted. Overall, this design has the advantages of high performance and strong anti-interference.

[1]  Yang Zhang,et al.  Design of a Matching Network for a High-Sensitivity Broadband Magnetic Resonance Sounding Coil Sensor , 2017, Sensors.

[2]  Shuang Zhang,et al.  Overhauser magnetometer sensor design for magnetic field observation , 2016, Optical Engineering + Applications.

[3]  Christopher M Collins,et al.  BirdcageBuilder: Design of Specified-Geometry Birdcage Coils with Desired Current Pattern and Resonant Frequency. , 2002, Concepts in magnetic resonance.

[4]  Noël Djongyang,et al.  A review of geophysical methods for geothermal exploration , 2015 .

[5]  Huan Liu,et al.  Construction of an Overhauser magnetic gradiometer and the applications in geomagnetic observation and ferromagnetic target localization , 2017 .

[6]  A. Abragam,et al.  OVERHAUSER EFFECT IN NONMETALS , 1955 .

[7]  Huan Liu,et al.  Noise characterization for the FID signal from proton precession magnetometer , 2017 .

[8]  Zhang Shuang,et al.  An RF Circuit for Overhauser Magnetometer Excitation , 2012, 2012 International Conference on Industrial Control and Electronics Engineering.

[9]  Mark C. Leifer,et al.  Resonant Modes of the Birdcage Coil , 1997 .

[10]  A. Overhauser Polarization of Nuclei in Metals , 1953 .

[11]  Jun Zhu,et al.  Overhauser Geomagnetic Sensor Based on the Dynamic Nuclear Polarization Effect for Magnetic Prospecting , 2016, Sensors.

[12]  Huan Liu,et al.  An Automatic Wideband 90° Phase Shifter for Optically Pumped Cesium Magnetometers , 2017, IEEE Sensors Journal.

[13]  M. Nabighian,et al.  The historical development of the magnetic method in exploration , 2005 .

[14]  Huan Liu,et al.  A High-Precision Frequency Measurement Algorithm for FID Signal of Proton Magnetometer , 2016, IEEE Transactions on Instrumentation and Measurement.