Methods for characterization and optimisation of measuring performance of stereoscopic x-ray systems with image intensifiers

The use of biplanar high-speed x-ray fluoroscopy to study fast, 3D movements that are inaccessible from external views has grown significantly in the past decade. Owing to the development of specialised software for calibration, distortion correction, and automated tracking of radio-opaque marker implants, this technique will soon become the standard to analyse skeletal kinematics of vertebrate animals. However, tests of important characteristics of biplanar x-ray systems, such as resolution and precision, remain scarce and incomplete. We present methods to determine imaging resolution and 3D stereoscopic and dynamic resolutions to follow moving markers in 3D, and demonstrate them on a newly installed stereoscopic x-ray system with image intensifiers. Using four-megapixel cameras, image resolution slightly surpasses previous reports. The spatial resolution appears to be optimal at magnification factors (ratio of source-to-detector to source-to-subject distance) between 1.33 and 2.20. This new information will allow biplanar x-ray system users to optimise the relative position of tube, subject, and image intensifiers.

[1]  Nicole Fruehauf,et al.  Radiologic Science For Technologists Physics Biology And Protection , 2016 .

[2]  Joseph J Crisco,et al.  Static and dynamic error of a biplanar videoradiography system using marker-based and markerless tracking techniques. , 2011, Journal of biomechanical engineering.

[3]  Elizabeth L Brainerd,et al.  Validation of XMALab software for marker-based XROMM , 2016, Journal of Experimental Biology.

[4]  Callum F Ross,et al.  Dynamic Musculoskeletal Functional Morphology: Integrating diceCT and XROMM , 2018, Anatomical record.

[5]  蓑原 伸一,et al.  陽子線 ・ 重粒子線治療 Quality Assurance のための Phantom , 1998 .

[6]  Hristo N Nikolov,et al.  A quality assurance phantom for the performance evaluation of volumetric micro-CT systems , 2007, Physics in medicine and biology.

[7]  E. Samei,et al.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device. , 1998, Medical physics.

[8]  S M Geiger,et al.  Validation of biplane high‐speed fluoroscopy combined with two different noninvasive tracking methodologies for measuring in vivo distal limb kinematics of the horse , 2018, Equine veterinary journal.

[9]  Sharon M. Swartz,et al.  Spring or string: does tendon elastic action influence wing muscle mechanics in bat flight? , 2015, Proceedings of the Royal Society B: Biological Sciences.

[10]  Elizabeth L Brainerd,et al.  Role of axial muscles in powering mouth expansion during suction feeding in largemouth bass (Micropterus salmoides) , 2014, Journal of Experimental Biology.

[11]  Peter Ch Snelderwaard,et al.  Digital video combined with conventional radiography creates an excellent high-speed X-ray video system. , 2002, Journal of biomechanics.

[12]  David B Baier,et al.  Scientific rotoscoping: a morphology-based method of 3-D motion analysis and visualization. , 2010, Journal of experimental zoology. Part A, Ecological genetics and physiology.

[13]  J Wang,et al.  The AAPM/RSNA physics tutorial for residents: X-ray image intensifiers for fluoroscopy. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[14]  M. Fischer,et al.  Three-dimensional movements of the pelvis and the lumbar intervertebral joints in walking and trotting dogs. , 2016, Veterinary journal.

[15]  S. Bushong,et al.  Radiologic science for technologists: physics, biology, and protection. [Textbook] , 1980 .

[16]  D. B. Baier,et al.  X-ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research. , 2010, Journal of experimental zoology. Part A, Ecological genetics and physiology.

[17]  Luo Yang,et al.  Shape preserving piecewise cubic interpolation , 1996 .

[18]  Henry C. Astley,et al.  Fluoromicrometry: A Method for Measuring Muscle Length Dynamics with Biplanar Videofluoroscopy. , 2016, Journal of experimental zoology. Part A, Ecological genetics and physiology.

[19]  B. Schueler Clinical applications of basic x-ray physics principles. , 1998, Radiographics : a review publication of the Radiological Society of North America, Inc.

[20]  P. Judy,et al.  The line spread function and modulation transfer function of a computed tomographic scanner. , 1976, Medical physics.