Fluence-to-dose conversion coefficients for monoenergetic proton beams based on the VIP-Man anatomical model.

A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients has been calculated for high-energy protons using the whole-body anatomical model VIP-Man, which was developed from the high-resolution transverse colour photographic images of the National Library of Medicine's Visible Human Project. For 10 monoenergetic proton beams between 20 and 10,000 MeV, organ dose calculations were performed using the Monte Carlo code MCNPX under six different irradiation geometries: anterior-posterior, posterior-anterior, left lateral, right lateral, isotropic and rotational. The absorbed dose results for 24 major organs of VIP-Man are presented and compared with those based on mathematical phantoms reported in the literature. The discrepancies (generally within 40%) in organ dose and effective dose estimates are attributed to the use of different transport models employed by different Monte Carlo codes.

[1]  W. S. Snyder,et al.  Calculation of radiation dose due to protons and neutrons with energies from 0.4 to 2.4 GeV. , 1969, Health physics.

[2]  W. E. Kinney,et al.  Calculated tissue current-to-dose conversion factors for nucleons below 400 MeV , 1965 .

[3]  X. Xu,et al.  Organ dose conversion coefficients for 0.1-10 MeV electrons calculated for the VIP-Man tomographic model. , 2001, Health physics.

[4]  D. G. Jones A Realistic Anthropomorphic Phantom for Calculating Organ Doses Arising from External Photon Irradiation , 1997 .

[5]  X. Xu,et al.  Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model , 2000, Physics in medicine and biology.

[6]  A. Bozkurt,et al.  VIP-MAN: AN IMAGE-BASED WHOLE-BODY ADULT MALE MODEL CONSTRUCTED FROM COLOR PHOTOGRAPHS OF THE VISIBLE HUMAN PROJECT FOR MULTI-PARTICLE MONTE CARLO CALCULATIONS , 2000, Health physics.

[7]  P J Reckwerdt,et al.  A proposal for a standard electronic anthropomorphic phantom for radiotherapy. , 1999, Medical physics.

[8]  X. Xu,et al.  Fluence-to-dose conversion coefficients based on the VIP-Man anatomical model and MCNPX code for monoenergetic neutrons above 20 MeV. , 2001, Health physics.

[9]  Y. Sakamoto,et al.  External Radiation Conversion Coefficients using Radiation Weighting Factor and Quality Factor for Neutron and Proton from 20 MeV to 10 GeV , 1998 .

[10]  W. A. Coleman,et al.  The absorbed dose and dose equivalent from neutrons in the energy range 60 to 3000 MeV and protons in the energy range 400 to 3000 MeV , 1970 .

[11]  W. S. Snyder,et al.  CALCULATION OF RADIATION DOSE FROM PROTONS TO 400 MEV. , 1964, Health physics.

[12]  W. S. Snyder,et al.  Calculation of radiation dose from protons and neutrons to 400 MeV. , 1966, Health physics.

[13]  W E Bolch,et al.  Creation of two tomographic voxel models of paediatric patients in the first year of life. , 2002, Physics in medicine and biology.

[14]  M. Pelliccioni,et al.  Fluence to Effective Dose Conversion Coefficients for Protons from 5 MeV to 10 TeV , 1997 .

[15]  M. Zankl,et al.  The adult male voxel model ”Golem” segmented from whole-body CT patient data , 2001, Radiation and environmental biophysics.

[16]  W. S. Snyder,et al.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. , 1974, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  M Caon,et al.  An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations. , 1999, Physics in medicine and biology.

[18]  Nina Petoussi-Henss,et al.  The GSF family of voxel phantoms , 2002, Physics in medicine and biology.

[19]  H. Takada,et al.  Development of High Energy Transport Code HETC-3STEP Applicable to the Nuclear Reaction with Incident Energies above 20MeV , 1995 .

[20]  Y. Yariv,et al.  Intranuclear cascade calculation of high-energy heavy-ion interactions , 1979 .

[21]  J. W. Vieira,et al.  All about FAX: a Female Adult voXel phantom for Monte Carlo calculation in radiation protection dosimetry. , 2003, Physics in medicine and biology.

[22]  X. Xu,et al.  Conversion coefficients based on the VIP-Man anatomical model and EGS4. , 2001, Health physics.