Evaluation of a frequency-domain ultrasonic imaging attenuation compensation technique

Ultrasound attenuation is typically compensated for in clinical scanners by using time gain compensation (TGC). However, TGC operates in a frequency-independent fashion and therefore the spatial resolution of the echographic images degrades as the examination depth increases. In the current study, the capability of a multi-band attenuation compensation (MBAC) TGC technique to recover both magnitude and spatial resolution in lossy media was evaluated. Simulations were performed using a 5-MHz transducer for imaging point targets embedded in a medium with attenuation coefficient slope (ACS) of 0.5 dB/(cm.MHz). For performance assessment, the magnitude and spatial resolution of the reflected point spread functions (PSFs) were compared to the ones obtained from point targets embedded in a lossless medium. The results showed a complete recovery of the spectral content when using MBAC for all depths when compared to the lossless case. Both the magnitude and spatial resolution of the compensated PSFs were in agreement with the lossless result (i.e., less than 1 dB and 3 % difference in PSF magnitude and spatial resolution, respectively). The MBAC was then applied to in vivo liver imaging using a scanner equipped with a 5-MHz linear array. Attenuation compensation was performed using ACSs reported in the literature for skin, fat and muscle, and experimentally estimated ACS using the spectral log difference technique for the liver. The lateral and axial extent of the autocorrelation function was estimated in the liver tissue. The experimental MBAC image exhibited only 6 % and 11 % variation in speckle magnitude and lateral autocorrelation length for depths between 2.5 and 4 cm. These results suggest that MBAC technique may enhance speckle uniformity in homogeneous tissue regions.

[1]  Yassin Labyed,et al.  A theoretical comparison of attenuation measurement techniques from backscattered ultrasound echoes. , 2011, The Journal of the Acoustical Society of America.

[2]  K. Parker,et al.  Comparison of techniques for in vivo attenuation measurements , 1988, IEEE Transactions on Biomedical Engineering.

[3]  A. Coron,et al.  Optimization of attenuation estimation in reflection for in vivo human dermis characterization at 20 MHz , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Olivier Basset,et al.  A multi-frequency approach to increase the native resolution of ultrasound images , 2012, 2012 Proceedings of the 20th European Signal Processing Conference (EUSIPCO).

[5]  J A Zagzebski,et al.  Ultrasound backscatter and attenuation in human liver with diffuse disease. , 1999, Ultrasound in medicine & biology.

[6]  M. Oelze,et al.  Improved parameter estimates based on the homodyned K distribution , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  Dan Inbar,et al.  Time gain compensation for ultrasonic medical imaging systems , 1990 .

[8]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.