Nonmetallic prestressing tendons, made of fibre-reinforced composite materials, are being proposed as alternatives to steel prestressing tendons for bridges and parking garage structures, where corrosion is the leading cause of structural deterioration. One type of commercially available nonmetallic tendons is made of pultruded aramid fibres. One of the main problems for these tendons, which is common to all nonmetallic tendons, is that the high ratio of the axial to lateral strength of fibre-reinforced materials requires special attention to the type of anchorage used. For the aramid tendon, the simplest grouted anchorage consists of a steel tube filled with nonshrink grout, into which the end of the tendon is embedded. This note presents the test results of a parametric study on grouted anchorages for pultruded aramid tendons. Key words: prestressed concrete, nonmetallic tendons, aramid fibre, grouted anchorage.