Implantable and wearable measurement system for smart knee prosthesis

In this work we present the implantable and wearable measurement system developed for smart knee prostheses monitoring. The kinematic measurement system contains three anisotropic magnetoresistive sensors embedded into the polyethylene part of the prostheses. The kinematic measurement system also has two inertial measurement units to be worn by the subject on the shank and thigh. Each of this inertial measurement units consisted of a 3D accelerometer and a 3D gyroscope. The force measurement system contains implantable strain gauges that connected in two separate Wheatstone bridges and embedded in a designed capsule-like structure. These systems were validated in a robotic knee simulator against reference force and kinematics systems. The best angle estimator performed with an RMS error of 1.18°±0.25° over four different walking patterns, while the force sensors showed linear behavior in measuring the applied forces, where linear models obtained R2s larger than 0.98.

[1]  O. Nelles Nonlinear System Identification , 2001 .

[2]  Oguz Atasoy,et al.  Full-duplex communication and remote powering implementation of an electronic knee implant , 2013, Proceedings of the 2013 9th Conference on Ph.D. Research in Microelectronics and Electronics (PRIME).

[3]  Arash Arami Kinematics Estimation and Loosening Detection in Smart Knee Prostheses , 2014 .

[4]  Kamiar Aminian,et al.  Estimation of prosthetic knee angles via data fusion of implantable and wearable sensors , 2013, 2013 IEEE International Conference on Body Sensor Networks.

[5]  G. Bergmann,et al.  Design, calibration and pre-clinical testing of an instrumented tibial tray. , 2007, Journal of biomechanics.

[6]  Marcus G Pandy,et al.  Grand challenge competition to predict in vivo knee loads , 2012, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  Pierre-André Farine,et al.  An Analog Front-End and ADC Integrated Circuit for Implantable Force and Orientation Measurements in Joint Prosthesis , 2012, MobiHealth.

[8]  In vivo hip joint loads during three methods of walking with forearm crutches. , 2013, Clinical biomechanics.

[9]  J. Bortz A New Mathematical Formulation for Strapdown Inertial Navigation , 1971, IEEE Transactions on Aerospace and Electronic Systems.

[10]  R. Villar Knee replacement. , 1990, The Practitioner.

[11]  B M Jolles,et al.  Functional calibration procedure for 3D knee joint angle description using inertial sensors. , 2009, Journal of biomechanics.

[12]  L. Rothman Properties of Thin Polyimide Films , 1980 .

[13]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[14]  Christopher Townsend,et al.  A multiaxial force-sensing implantable tibial prosthesis. , 2006, Journal of biomechanics.

[15]  Oguz Atasoy,et al.  Instrumented Knee Prosthesis for Force and Kinematics Measurements , 2013, IEEE Transactions on Automation Science and Engineering.

[16]  Kamiar Aminian,et al.  Accurate Measurement of Concurrent Flexion–Extension and Internal–External Rotations in Smart Knee Prostheses , 2013, IEEE Transactions on Biomedical Engineering.

[17]  Jean-Philippe Thiran,et al.  Soft Tissue Artifact Assessment During Treadmill Walking in Subjects With Total Knee Arthroplasty , 2013, IEEE Transactions on Biomedical Engineering.

[18]  D. D’Lima,et al.  Tibial forces measured in vivo after total knee arthroplasty. , 2006, The Journal of arthroplasty.

[19]  Kamiar Aminian,et al.  Accurate internal-external rotation measurement in total knee prostheses: A magnetic solution. , 2012, Journal of biomechanics.