Pseudo transient numerical study of an earth-to-air heat exchanger for different climates of México

Abstract The numerical study of the pseudo transient thermal behavior of an earth-to-air heat exchanger (EAHE) for three cities in Mexico is presented. The climate conditions correspond to the warmest day in summer and the coldest day in winter for: extreme weather (Juarez city, Chihuahua), mild weather (Mexico city, D.F.) and hot weather (Merida, Yucatan). The simulations of the EAHE were done in an in-house code based on the finite volume method. Hourly simulations were done for four Reynolds numbers (100, 500, 1000, 1500) through one day. In Juarez city, the EAHE worked correctly for cooling and heating purposes during the whole day. For Merida and Mexico City the EAHE did not work during certain periods. The maximum cooling potential provided by the EAHE was 17.4, 10.2 and 10 °C in Juarez, Merida and Mexico City, respectively. The maximum heating potential provided by the EAHE was 6.3, 12.5 and 3.2 °C in Juarez, Merida and Mexico City, respectively. Such cooling and heating effects help to improve the thermal comfort inside a building located in this type of climates.

[1]  Bruno Peuportier,et al.  Thermal and environmental assessment of a passive building equipped with an earth-to-air heat exchanger in France , 2008 .

[2]  J. C. Jaeger,et al.  Conduction of Heat in Solids , 1952 .

[3]  Bo Nordell,et al.  Using Fouggara for Heating and Cooling Buildings in Sahara , 2011 .

[4]  G. Mihalakakou,et al.  Energy conservation in greenhouses with buried pipes , 1996 .

[5]  S. C. Kaushik,et al.  Heating and cooling potential of an earth-to-air heat exchanger using artificial neural network , 2006 .

[6]  Pierre Hollmuller,et al.  Cooling and preheating with buried pipe systems: monitoring, simulation and economic aspects , 2001 .

[7]  Paul Christodoulides,et al.  An analysis of heat flow through a borehole heat exchanger validated model , 2012 .

[8]  M. Santamouris,et al.  On the performance of buildings coupled with earth to air heat exchangers , 1995 .

[9]  D. N. Asimakopoulos,et al.  Modelling the thermal performance of earth-to-air heat exchangers , 1994 .

[10]  G. Mihalakakou,et al.  On the application of the energy balance equation to predict ground temperature profiles , 1997 .

[11]  M. M. Salah El-Din,et al.  On the heat flow into the ground , 1999 .

[12]  G. Mihalakakou,et al.  Impact of ground cover on the efficiencies of earth-to-air heat exchangers , 1994 .

[13]  Miroslav Bojic,et al.  Numerical simulation, technical and economic evaluation of air-to-earth heat exchanger coupled to a building , 1997 .

[14]  Onder Ozgener,et al.  Determining the optimal design of a closed loop earth to air heat exchanger for greenhouse heating b , 2011 .

[15]  L. Montoro,et al.  A one-dimensional transient analytical model for earth-to-air heat exchangers, taking into account condensation phenomena and thermal perturbation from the upper free surface as well as around the buried pipes , 2008 .

[16]  J. P. V. Doormaal,et al.  ENHANCEMENTS OF THE SIMPLE METHOD FOR PREDICTING INCOMPRESSIBLE FLUID FLOWS , 1984 .

[17]  M. K. Ghosal,et al.  Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse , 2005 .

[18]  C. Gauthier,et al.  Numerical simulation of soil heat exchanger-storage systems for greenhouses , 1997 .

[19]  A. Busso,et al.  First in situ determination of ground and borehole thermal properties in Latin America , 2004 .

[20]  Viorel Badescu,et al.  Simple and accurate model for the ground heat exchanger of a passive house , 2007 .

[21]  Masaya Okumiya,et al.  Study on the design procedure for a multi-cool/heat tube system , 2009 .

[22]  Eduardo Blanco,et al.  Numerical Investigation of Horizontal Ground Coupled Heat Exchanger , 2011 .

[23]  Hua Su,et al.  A numerical model of a deeply buried air–earth–tunnel heat exchanger , 2012 .

[24]  Quirijn de Jong van Lier,et al.  Testing a finite-difference model for soil heat transfer by comparing numerical and analytical solutions , 2004, Environ. Model. Softw..

[25]  Shengwei Wang,et al.  Modelling and evaluation of cooling capacity of earth-air-pipe systems , 2007 .

[26]  J. Xamán,et al.  Numerical study of earth-to-air heat exchanger: The effect of thermal insulation , 2014 .

[27]  Vitor A. F. Costa,et al.  Thermodynamic analysis of building heating or cooling using the soil as heat reservoir , 2006 .

[28]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[29]  George Papadakis,et al.  Energy from a two-pipe, earth-to-air heat exchanger , 1999 .

[30]  Mohammed Tamali,et al.  The Potential of Earth-air Heat Exchangers for Low Energy Cooling of Buildings in South Algeria , 2012 .

[31]  Jyotirmay Mathur,et al.  CFD analysis of EATHE system under transient conditions for intermittent operation , 2015 .

[32]  J. Xamán,et al.  Numerical study of earth-to-air heat exchanger for three different climates , 2014 .

[33]  Arnold Janssens,et al.  Thermo-hydraulic design of earth-air heat exchangers , 2003 .

[34]  I. Sezai,et al.  Natural convection in C-shaped thermosyphon , 1997 .

[35]  Jyotirmay Mathur,et al.  CFD analysis based parametric study of derating factor for Earth Air Tunnel Heat Exchanger , 2013 .

[36]  Etienne Wurtz,et al.  Modelling earth-to-air heat exchanger behaviour with the convolutive response factors method , 2009 .