Optimising dissolved air flotation/filtration treatment of algae-laden lagoon effluent using surface charge: a Bolivar treatment plant case study.

Dissolved air flotation (DAF) incorporating filtration (DAFF) is used at the Bolivar wastewater treatment plant (WWTP) to polish lagoon effluent for reuse. Elevated algal populations are frequently experienced and can lead to increased coagulant requirements and process control issues. Streaming current detectors (SCDs) and a charge demand analyser (CDA) were used to monitor the full-scale plant. This was followed by an optimisation study using a pilot plant with a CDA. It was found that the normal operational charge demand range for DAF at Bolivar was between -46 and -40 μeq L(-1). Decreasing the pH of coagulation reduced coagulant consumption and facilitated more sensitive CDA responses to changes in alum dose.

[1]  B. Jefferson,et al.  The impact of differing cell and algogenic organic matter (AOM) characteristics on the coagulation and flotation of algae. , 2010, Water research.

[2]  J. K. Edzwald Dissolved air flotation and me. , 2010, Water research.

[3]  A. M. Jacobson,et al.  Role of Zeta (ζ) Potential in the Optimization of Water Treatment Facility Operations , 2009 .

[4]  B. Jefferson,et al.  Successful Removal of Algae through the Control of Zeta Potential , 2008 .

[5]  Bruce Jefferson,et al.  The impact of algal properties and pre-oxidation on solid-liquid separation of algae. , 2008, Water research.

[6]  Seockheon Lee,et al.  Automatic control of polymer dosage using streaming potential for waterworks sludge conditioning , 2007 .

[7]  John Gregory,et al.  Organic polyelectrolytes in water treatment. , 2007, Water research.

[8]  B. Jefferson,et al.  The impact of zeta potential on the physical properties of ferric--NOM flocs. , 2006, Environmental science & technology.

[9]  B. Jefferson,et al.  Application of zeta potential measurements for coagulation control: pilot-plant experiences from UK and US waters with elevated organics , 2005 .

[10]  A Adgar,et al.  Enhancement of coagulation control using the streaming current detector , 2005, Bioprocess and biosystems engineering.

[11]  B. Jefferson,et al.  Application of charge measurement to water treatment processes , 2004 .

[12]  J. Gregory,et al.  Coagulation by hydrolysing metal salts , 2003 .

[13]  S K Kam,et al.  The interaction of humic substances with cationic polyelectrolytes. , 2000, Water research.

[14]  H. Bernhardt,et al.  Control of flocculants by use of a streaming current detector (SCD) , 1993 .

[15]  Kate Walton,et al.  The impact. , 2013, Iowa medicine : journal of the Iowa Medical Society.

[16]  H. Schell,et al.  EXPERIENCE IN COAGULANT CONTROL BY USE OF A CHARGE TITRATION UNIT , 1996 .