Resonant wavelength shift detection system based on a gradient grating period guided-mode resonance filter

A resonant wavelength detection system based on a gradient grating period guided-mode resonance (GGP-GMR) filter and a linear charge-coupled device is demonstrated. The GGP-GMR used in this work consists of a subwavelength grating structure with a grating period varying from 250–550 nm in increments of 2 nm. We successfully demonstrate that by using this system, we can monitor the shift in a biosensor’s dip wavelength caused by different sucrose concentrations. This technology has the potential to replace a bulky and expensive spectrometer used in most optical biosensor systems. Given its compactness, the system can be integrated with lab-on-a-chip systems for numerous biosensing applications.

[1]  Chih-Wei Chang,et al.  Compact spectrometer system based on a gradient grating period guided-mode resonance filter. , 2016, Optics express.

[2]  A. Di Falco,et al.  Slotted photonic crystal cavities with integrated microfluidics for biosensing applications. , 2011, Biosensors & bioelectronics.

[3]  Noel H. Wan,et al.  Waveguide-integrated photonic crystal spectrometer with camera readout , 2014 .

[4]  Yuze Sun,et al.  Sensitive optical biosensors for unlabeled targets: a review. , 2008, Analytica chimica acta.

[5]  J. Homola Present and future of surface plasmon resonance biosensors , 2003, Analytical and bioanalytical chemistry.

[6]  Y. Tu,et al.  Integration of a guided-mode resonance filter with microposts for in-cell protein detection. , 2016, The Analyst.

[7]  R. Magnusson,et al.  New principle for optical filters , 1992 .

[8]  Robert Magnusson,et al.  Photonic devices enabled by waveguide-mode resonance effects in periodically modulated films , 2003, SPIE Optics + Photonics.

[9]  Cheng-Sheng Huang,et al.  Linear Variable Filter Based on a Gradient Grating Period Guided-Mode Resonance Filter , 2016, IEEE Photonics Technology Letters.

[10]  B. Cunningham,et al.  Colorimetric resonant reflection as a direct biochemical assay technique , 2002, Technical Digest. MEMS 2002 IEEE International Conference. Fifteenth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.02CH37266).

[11]  Reginald K. Lee,et al.  Highly sensitive fiber Bragg grating refractive index sensors , 2005 .

[12]  Min-Cheol Oh,et al.  Polymeric waveguide biosensors with calixarene monolayer for detecting potassium ion concentration , 2006 .

[13]  Adriana Szeghalmi,et al.  Theoretical and Experimental Analysis of the Sensitivity of Guided Mode Resonance Sensors , 2010 .