Identification of Movements and Postures Using Wearable Sensors for Implementation in a Bi-Hormonal Artificial Pancreas System

Background: Closed loop bi-hormonal artificial pancreas systems, such as the artificial pancreas (AP™) developed by Inreda Diabetic B.V., control blood glucose levels of type 1 diabetes mellitus patients via closed loop regulation. As the AP™ currently does not classify postures and movements to estimate metabolic energy consumption to correct hormone administration levels, considerable improvements to the system can be made. Therefore, this research aimed to investigate the possibility to use the current system to identify several postures and movements. Methods: seven healthy participants took part in an experiment where sequences of postures and movements were performed to train and assess a computationally sparing algorithm. Results: Using accelerometers, one on the hip and two on the abdomen, user-specific models achieved classification accuracies of 86.5% using only the hip sensor and 87.3% when including the abdomen sensors. With additional accelerometers on the sternum and upper leg for identification, 90.0% of the classified postures and movements were correct. Conclusions: The current hardware configuration of the AP™ poses no limitation to the identification of postures and movements. If future research shows that identification can still be done accurately in a daily life setting, this algorithm may be an improvement for the AP™ to sense physical activity.

[1]  Emanuele Lindo Secco,et al.  A Real-Time and Self-Calibrating Algorithm Based on Triaxial Accelerometer Signals for the Detection of Human Posture and Activity , 2010, IEEE Transactions on Information Technology in Biomedicine.

[2]  M. Rendell,et al.  The Dawn Phenomenon, an Early Morning Glucose Rise: Implications for Diabetic Intraday Blood Glucose Variation , 1981, Diabetes Care.

[3]  J. D. Janssen,et al.  Daily physical activity assessment: comparison between movement registration and doubly labeled water. , 1996, Journal of applied physiology.

[4]  R. Koops,et al.  Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home , 2016, Diabetes, obesity & metabolism.

[5]  Wai Yin Wong,et al.  Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review , 2007, Prosthetics and orthotics international.

[6]  W. Spector,et al.  The hierarchical relationship between activities of daily living and instrumental activities of daily living. , 1987, Journal of chronic diseases.

[7]  E. Mohammadi,et al.  Barriers and facilitators related to the implementation of a physiological track and trigger system: A systematic review of the qualitative evidence , 2017, International journal for quality in health care : journal of the International Society for Quality in Health Care.

[8]  R. Bucks,et al.  Assessment of activities of daily living in dementia: development of the Bristol Activities of Daily Living Scale. , 1996, Age and ageing.

[9]  Eyal Dassau,et al.  Early Detection of Physical Activity for People With Type 1 Diabetes Mellitus , 2015, Journal of diabetes science and technology.

[10]  J. DeVries,et al.  Fully Closed Loop Glucose Control With a Bihormonal Artificial Pancreas in Adults With Type 1 Diabetes: An Outpatient, Randomized, Crossover Trial , 2021, Diabetes Care.

[11]  Friedrich Foerster,et al.  Detection of posture and motion by accelerometry : a validation study in ambulatory monitoring , 1999 .

[12]  J. D. Janssen,et al.  A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity , 1997, IEEE Transactions on Biomedical Engineering.

[13]  Christian Chatellier,et al.  Sensor-to-Segment Calibration Methodologies for Lower-Body Kinematic Analysis with Inertial Sensors: A Systematic Review , 2020, Sensors.

[14]  Nicholas Preiser,et al.  Incorporating an Exercise Detection, Grading, and Hormone Dosing Algorithm Into the Artificial Pancreas Using Accelerometry and Heart Rate , 2015, Journal of diabetes science and technology.

[15]  P H Veltink,et al.  Detection of static and dynamic activities using uniaxial accelerometers. , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[16]  Kenton R Kaufman,et al.  Posture and movement classification: the comparison of tri-axial accelerometer numbers and anatomical placement. , 2014, Journal of biomechanical engineering.

[17]  T. Jones,et al.  The decline in blood glucose levels is less with intermittent high-intensity compared with moderate exercise in individuals with type 1 diabetes. , 2005, Diabetes care.