Frequency-Adaptive Modified Comb-Filter-Based Phase-Locked Loop for a Doubly-Fed Adjustable-Speed Pumped-Storage Hydropower Plant under Distorted Grid Conditions

The control system of a doubly-fed adjustable-speed pumped-storage hydropower plant needs phase-locked loops (PLLs) to obtain the phase angle of grid voltage. The main drawback of a comb-filter-based phase-locked loop (CF-PLL) is the slow dynamic response. This paper presents a modified comb-filter-based phase-locked loop (MCF-PLL) by improving the pole-zero pattern of the comb filter, and gives the parameters’ setting method of the controller, based on the discrete model of MCF-PLL. In order to improve the disturbance resistibility of MCF-PLL when the power grid’s frequency changes, this paper proposes a frequency-adaptive modified, comb-filter-based, phase-locked loop (FAMCF-PLL) and its digital implementation scheme. Experimental results show that FAMCF-PLL has good steady-state and dynamic performance under distorted grid conditions. Furthermore, FAMCF-PLL can determine the phase angle of the grid voltage, which is locked when it is applied to a doubly-fed adjustable-speed pumped-storage hydropower experimental platform.

[1]  Josep M. Guerrero,et al.  PLL With MAF-Based Prefiltering Stage: Small-Signal Modeling and Performance Enhancement , 2016, IEEE Transactions on Power Electronics.

[2]  François Avellan,et al.  Dynamical Behavior Comparison Between Variable Speed and Synchronous Machines With PSS , 2010, IEEE Transactions on Power Systems.

[3]  Bin Wu,et al.  Current-Source Converter and Cycloconverter Topologies for Industrial Medium-Voltage Drives , 2008, IEEE Transactions on Industrial Electronics.

[4]  Josep M. Guerrero,et al.  Conventional Synchronous Reference Frame Phase-Locked Loop is an Adaptive Complex Filter , 2015, IEEE Transactions on Industrial Electronics.

[5]  Y. Li,et al.  Analysis and Digital Implementation of Cascaded Delayed-Signal-Cancellation PLL , 2011, IEEE Transactions on Power Electronics.

[6]  Josep M. Guerrero,et al.  An Adaptive Quadrature Signal Generation-Based Single-Phase Phase-Locked Loop for Grid-Connected Applications , 2017, IEEE Transactions on Industrial Electronics.

[7]  Heng Nian,et al.  Direct Power Control of Doubly Fed Induction Generator Under Distorted Grid Voltage , 2014, IEEE Transactions on Power Electronics.

[8]  Bin Wu,et al.  A Novel Hardware-Based All-Digital Phase-Locked Loop Applied to Grid-Connected Power Converters , 2011, IEEE Transactions on Industrial Electronics.

[9]  Geng Yang,et al.  Enhanced model of the doubly fed induction generator-based wind farm for small-signal stability studies of weak power system , 2014 .

[10]  Lie Xu,et al.  Direct Power Control of DFIG With Constant Switching Frequency and Improved Transient Performance , 2007, IEEE Transactions on Energy Conversion.

[11]  Stephen J. Finney,et al.  Three-phase phase-lock loop for distorted utilities , 2007 .

[12]  P. Allenbach,et al.  Dynamic behavior of a 2 variable speed pump-turbine power plant , 2008, 2008 18th International Conference on Electrical Machines.

[13]  Andreas Poullikkas,et al.  Overview of current and future energy storage technologies for electric power applications , 2009 .

[14]  Jing Ma,et al.  Research on the Impact of DFIG Virtual Inertia Control on Power System Small-Signal Stability Considering the Phase-Locked Loop , 2017, IEEE Transactions on Power Systems.

[15]  Bimal K. Bose,et al.  Global Energy Scenario and Impact of Power Electronics in 21st Century , 2013, IEEE Transactions on Industrial Electronics.

[16]  Gabriel Garcerá,et al.  An Adaptive Synchronous-Reference-Frame Phase-Locked Loop for Power Quality Improvement in a Polluted Utility Grid , 2012, IEEE Transactions on Industrial Electronics.

[17]  G. Scelba,et al.  Fault-Decoupled Instantaneous Frequency and Phase Angle Estimation for Three-Phase Grid-Connected Inverters , 2016, IEEE Transactions on Power Electronics.

[18]  Sanjit K. Mitra,et al.  A new two-stage sharpened comb decimator , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[19]  Josep M. Guerrero,et al.  Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines , 2014, IEEE Transactions on Power Electronics.

[20]  Geng Yang,et al.  Coordinated Control of a Doubly-Fed Induction Generator-Based Wind Farm and a Static Synchronous Compensator for Low Voltage Ride-through Grid Code Compliance during Asymmetrical Grid Faults , 2013 .

[21]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[22]  Juan C. Vasquez,et al.  A Critical Examination of Frequency-Fixed Second-Order Generalized Integrator-Based Phase-Locked Loops , 2017, IEEE Transactions on Power Electronics.

[23]  Pablo Fernandez-Comesana,et al.  A Signal-Processing Adaptive Algorithm for Selective Current Harmonic Cancellation in Active Power Filters , 2009, IEEE Transactions on Industrial Electronics.

[24]  Josep M. Guerrero,et al.  Design and Tuning of a Modified Power-Based PLL for Single-Phase Grid-Connected Power Conditioning Systems , 2012, IEEE Transactions on Power Electronics.

[25]  Zhong Wang,et al.  Effect of Erroneous Position Measurements in Vector-Controlled Doubly Fed Induction Generator , 2010, IEEE Transactions on Energy Conversion.