Optimum flip‐angles for exciting NMR with uncertain T1 values

T1 is often ill‐determined. This means that an Ernst angle excitation often cannot be precisely defined for the simple pulse and acquire experiment. Here, published 31P T1 values of metabolites in human muscle, liver, heart, and brain are archived, some new data on heart and brain added, and overall confidence intervals determined. Strategies for setting the flip‐angle based on the confidence intervals are examined, and an optimum flip‐angle derived which minimizes the signal loss relative to what could have been realized if T1 were precisely known. With such optimized pulses, signal loss can be limited to ≤14% for up to a 10‐fold variation in T1, with TR ≤ T1 The effect that an uncertainty in T1 by a factor of two has on the saturation corrected signal is limited to ≤20% in the optimum flip‐angle experiment. Adiabatic B1‐independent rotation phase‐cycled (BIRP) excitation pulses are ideal as optimum flip‐angle pulses as they can be prescribed without calibration.

[1]  G S Karczmar,et al.  Non‐invasive quantitation of human liver metabolites using image‐guided 31p magnetic resonance spectroscopy , 1990, NMR in biomedicine.

[2]  P R Luyten,et al.  Experimental approaches to image localized human 31P NMR spectroscopy , 1989, Magnetic resonance in medicine.

[3]  C. Hardy,et al.  Regional myocardial metabolism of high-energy phosphates during isometric exercise in patients with coronary artery disease. , 1990, The New England journal of medicine.

[4]  C. Hardy,et al.  Correcting human heart 31P NMR spectra for partial saturation. Evidence that saturation factors for PCr/ATP are homogeneous in normal and disease states , 1991 .

[5]  G. Radda,et al.  Detection of low phosphocreatine to ATP ratio in failing hypertrophied human myocardium by 31P magnetic resonance spectroscopy , 1991, The Lancet.

[6]  G. Radda,et al.  The study of human organs by phosphorus-31 topical magnetic resonance spectroscopy. , 1987, The British journal of radiology.

[7]  T. Parrish,et al.  3-D FLASH imaging using a single surface coil and a new adiabatic pulse, BIR-4. , 1990, Investigative radiology.

[8]  C. Hardy,et al.  A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic? , 1987, Medical physics.

[9]  K Uğurbil,et al.  31P NMR spectroscopy of the human heart at 4 T: Detection of substantially uncontaminated cardiac spectra and differentiation of subepicardium and subendocardium , 1992, Magnetic resonance in medicine.

[10]  G. Radda,et al.  Measurement of in Vivo 31P relaxation rates and spectral editing in human organs using rotating-frame depth selection , 1987 .

[11]  P. Bottomley The true T1 values of myocardial high‐energy phosphates? , 1993, Magnetic resonance in medicine.

[12]  A. Haase,et al.  Direct measurement of spin‐lattice relaxation times of Phosphorus Metabolites in Human Myocardium , 1992, Magnetic resonance in medicine.

[13]  S. Nelson,et al.  Measurement of T1 relaxation times of cardiac phosphate metabolites using BIR‐4 adiabatic RF pulses and a variable nutation method , 1993, Magnetic resonance in medicine.

[14]  Paul A Bottomley,et al.  The Dual-Angle Method for Fast, Sensitive T1 Measurement in Vivo with Low-Angle Adiabatic Pulses , 1994 .

[15]  A method for rapid evaluation of saturation factors in in vivo surface coil NMR spectroscopy using B1‐insensitive pulse cycles , 1990, NMR in biomedicine.

[16]  M. Weiner,et al.  Noninvasive quantitation of phosphorus metabolites in human tissue by NMR spectroscopy , 1989 .

[17]  P. Bottomley,et al.  BIRP, an improved implementation of low-angle adiabatic (BIR-4) excitation pulses , 1993 .

[18]  Truman R. Brown,et al.  In vivo1 values of phosphorus metabolites in human liver and muscle determined at 1.5T by chemical shift imaging , 1989 .

[19]  D. van Ormondt,et al.  2D approach to quantitation of inversion-recovery data , 1990 .

[20]  A. Haase,et al.  Rapid NMR Imaging Using Low Flip-Angle Pulses , 2004 .

[21]  W. Edelstein,et al.  Spin warp NMR imaging and applications to human whole-body imaging. , 1980, Physics in medicine and biology.

[22]  G B Matson,et al.  P-31 MR spectroscopy of normal human brain and brain tumors. , 1990, Radiology.