Advances in assessment methods for fire safety

Abstract In this paper, the term ‘assessment method’ implies a broad class of standardized experiments which are used in the process of evaluating the fire safety of materials, products or systems. A subset of methods exists which has traditionally been referred to as ‘fire tests’. A brief history of full-scale and bench-scale fire tests is presented. A framework for evaluating the fire performance of building elements, assemblies, contents or materials is described and used to discuss the recent advances in fire tests. The role of fire scenarios is discussed in the context of assessment methods. The continuing theme throughout the paper is the impact of the oxygen depletion method of measuring the rate of heat release, one of the most important advances in the assessment of fire safety during the past 15 years. Corner tests of wall coverings including the effects of changing ‘stand off’ distance between ignition source and the wall of a corner test are discussed. Representative data from a series of different experiments are given to illustrate the use of corner tests. A concept of the critical ignition energy to cause propagation is introduced.

[1]  Pierce T. Pigott The fire at the stardust, Dublin: The public inquiry and its findings , 1984 .

[2]  James G. Quintiere,et al.  Some Factors Influencing Fire Spread Over Room Linings and in the Astm E-84 Tunnel Test , 1985 .

[3]  Vytenis Babrauskas,et al.  The historical basis of fire resistance testing — Part I , 1978 .

[4]  P. L. Hinkley,et al.  Experiments on the interaction between individual products involved in the artane fire , 1984 .

[5]  F. L. Fisher,et al.  Fire growth experiments: toward a standard room fire test , 1980 .

[6]  H. A. Smith,et al.  Forest products laboratory. , 1922 .

[7]  R. B. Williamson,et al.  Smoke Emission Factors from Medium-Scale Fires: Part 2 , 1989 .

[8]  Frederick W. Mowrer,et al.  Observations of Large Scale Turbulence in Corner-Wall Experiments , 1984 .

[9]  Bobbie Rogowski A critique of the fire test methods used to assess individual products involved in the Artane fire , 1984 .

[10]  R. B. Williamson,et al.  Ignition Sources In Room Fire Tests And Some Implications For Flame Spread Evaluation , 1991 .

[11]  R. B. Williamson,et al.  Smoke Emission Factors from Medium-Scale Fires: Part 1 , 1989 .

[12]  Clayton Huggett,et al.  Estimation of rate of heat release by means of oxygen consumption measurements , 1980 .

[13]  R. B. Williamson,et al.  Post‐flashover compartment fires: Basis of a theoretical model , 1978 .

[14]  Frederick W. Mowrer,et al.  A room fire screening test procedure , 1983 .

[15]  P. J. Fardell,et al.  The stardust disco fire, Dublin 1981: studies of combustion products during simulation experiments , 1984 .

[16]  W. A. Morris Stardust disco investigation - Some observations on the full-scale fire tests , 1984 .

[17]  W. Parker,et al.  Calculations of the Heat Release Rate by Oxygen Consumption for Various Applications , 1982 .

[18]  P.L. Hinkley,et al.  THE CONTRIBUTION OF FLAMES UNDER CEILINGS TO FIRE SPREAD IN COMPARTMENTS PART II. COMBUSTIBLE CEILING LININGS , 1968 .