Optimal configuration of adhesive ECG patches suitable for long-term monitoring of a vectorcardiogram.

The purpose of this study was to develop optimal configuration of adhesive ECG patches placement on the torso, which would provide the best agreement with the Frank orthogonal ECGs. Ten seconds of orthogonal ECG followed by 3-5min of ECGs using patches at 5 different locations simultaneously on the torso were recorded in 50 participants at rest in sitting position. Median beat was generated for each ECG and 3 patch ECGs that best correlate with orthogonal ECGs were selected for each participant. For agreement analysis, spatial QRS-T angle, spatial QRS and T vector characteristics, spatial ventricular gradient, roundness, thickness and planarity of vectorcardiographic (VCG) loops were measured. Key VCG parameters showed high agreement in Bland-Altman analysis (spatial QRS-T angle on 3-patch ECG vs. Frank ECG bias 0.3 (95% limits of agreement [-6.23;5.71 degrees]), Lin's concordance coefficient=0.996). In conclusion, newly developed orthogonal 3-patch ECG can be used for long-term VCG monitoring.

[1]  S. Horinaka,et al.  Spatial orientation of the vectorcardiogram in patients with myocardial infarction. , 1993, Japanese circulation journal.

[2]  Sebastian Zaunseder,et al.  Effects of ECG sampling rate on QT interval variability measurement , 2016, Biomed. Signal Process. Control..

[3]  Larisa G. Tereshchenko,et al.  Comparison of Sum Absolute QRST Integral, and Temporal Variability in Depolarization and Repolarization, Measured by Dynamic Vectorcardiography Approach, in Healthy Men and Women , 2013, PloS one.

[4]  H. Mann A METHOD OF ANALYZING THE ELECTROCARDIOGRAM , 1920 .

[5]  S. Bauer,et al.  Biocompatible and Biodegradable Materials for Organic Field‐Effect Transistors , 2010 .

[6]  Jonathan W. Waks,et al.  Quantitative Assessment of Vectorcardiographic Loop Morphology. , 2016, Journal of electrocardiology.

[7]  R. McFee,et al.  Electrocardiographic Leads: I. Introduction , 1953, Circulation.

[8]  Hugh Calkins,et al.  A new electrocardiogram marker to identify patients at low risk for ventricular tachyarrhythmias: sum magnitude of the absolute QRST integral. , 2011, Journal of electrocardiology.

[9]  D. Morlet,et al.  Planarity of the spatial QRS loop. Comparative analysis in normals, infarcts, ventricular hypertrophies, and intraventricular conduction defects. , 1989, Journal of electrocardiology.

[10]  R. McFee,et al.  An orthogonal lead system for clinical electrocardiography , 1961 .

[11]  David D Spragg,et al.  Ventricular arrhythmia is predicted by sum absolute QRST integralbut not by QRS width. , 2010, Journal of electrocardiology.

[12]  J A BOONE,et al.  The vectorcardiogram. , 1957, Journal of the South Carolina Medical Association.

[13]  David J Gladstone,et al.  Atrial fibrillation in patients with cryptogenic stroke. , 2014, The New England journal of medicine.

[14]  Raeed H. Chowdhury,et al.  Epidermal Electronics , 2011, Science.

[15]  E. Topol,et al.  Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. , 2014, The American journal of medicine.

[16]  K. Djupsund,et al.  Flexible polyimide microelectrode array for in vivo recordings and current source density analysis. , 2007, Biosensors & bioelectronics.

[17]  R. McFee,et al.  Electrocardiographic Leads: III. Synthesis , 1954, Circulation.

[18]  P. Laguna,et al.  Respiration effect on single and multi lead ECG delineation strategies , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[19]  M. Turakhia,et al.  Diagnostic utility of a novel leadless arrhythmia monitoring device. , 2013, The American journal of cardiology.

[20]  H. C. Burger,et al.  HEART-VECTOR AND LEADS. Part II , 1947, British heart journal.

[21]  Mark E. Josephson,et al.  Beat‐to‐Beat Spatiotemporal Variability in the T Vector Is Associated With Sudden Cardiac Death in Participants Without Left Ventricular Hypertrophy: The Atherosclerosis Risk in Communities (ARIC) Study , 2015, Journal of the American Heart Association.

[22]  D. Singer,et al.  Prevalence of diagnosed atrial fibrillation in adults: national implications for rhythm management and stroke prevention: the AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study. , 2001, JAMA.

[23]  Mark D. Huffman,et al.  Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association , 2016, Circulation.

[24]  Ernest Frank,et al.  General Theory of Heart‐Vector Projection , 1954 .

[25]  D B Geselowitz Electric and magnetic field of the heart. , 1973, Annual review of biophysics and bioengineering.

[26]  Joel Stein,et al.  Heart Disease and Stroke Statistics – At-a-Glance , 2015 .

[27]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[28]  Jonathan W. Waks,et al.  Global Electric Heterogeneity Risk Score for Prediction of Sudden Cardiac Death in the General Population: The Atherosclerosis Risk in Communities (ARIC) and Cardiovascular Health (CHS) Studies , 2016, Circulation.

[29]  P. Laguna,et al.  Dynamic analysis of multi lead ECG recordings for detection and categorization of respiratory events during sleep , 2007, 2007 Computers in Cardiology.

[30]  Mark E. Josephson,et al.  Analysis of speed, curvature, planarity and frequency characteristics of heart vector movement to evaluate the electrophysiological substrate associated with ventricular tachycardia , 2015, Comput. Biol. Medicine.

[31]  Michael A Rosenberg,et al.  Use of a Noninvasive Continuous Monitoring Device in the Management of Atrial Fibrillation: A Pilot Study , 2012, Pacing and clinical electrophysiology : PACE.

[32]  F D JOHNSTON,et al.  Electrocardiographic Leads: II. Analysis , 1954, Circulation.

[33]  Ernestfrank An Accurate, Clinically Practical System For Spatial Vectorcardiography , 1956 .

[34]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[35]  H. C. Burger,et al.  HEART-VECTOR AND LEADS. , 1946, British heart journal.