Use of an unintensified charge-coupled device detector for low-light-level Raman spectroscopy

Spontaneous Raman scattering from adsorbates on surfaces is a powerful vibrational spectroscopy technique that is due to the very large frequency range and high resolution currently possible with visible lasers and spectrometers. Because of the extremely low Raman cross sections of nonresonant molecules, one must use either some sort of signal-enhancement technique or long integrations using multichannel detection in order to have monolayer sensitivity. We have used a backthinned, unintensified, liquid-nitrogen-cooled charge-coupled device (CCD) detector to obtain high-quality multichannel unenhanced Raman scattering spectra from organic monolayers on surfaces. This system has roughly a factor-of-10 greater sensitivity for very low-light-level visible excitation Raman spectra than intensified multichannel detectors currently on the market. A description of our detection system is given along with a comparison with other commercially available multichannel detectors suitable for low-light-level visible Raman spectroscopy. We discuss the advantages and disadvantages of using CCD’s, the special problems that one encounters in their use as Raman detectors, and our methods for overcoming these problems. Prospects for the future use of CCD’s for low-light-level Raman spectroscopy will also be discussed.

[1]  N. E. Schlotter,et al.  Characterization of order in langmuir-blodgett monolayers by unenhanced Raman spectroscopy , 1987 .

[2]  Robert Nemanich,et al.  Interference-enhanced raman scattering of very thin titanium and titanium oxide films , 1980 .

[3]  Y. Talmi Spectrophotometry and Spectrofluorometry with the Self-Scanned Photodiode Array , 1982 .

[4]  A. Campion,et al.  Surface Raman spectroscopy without enhancement: Nitrobenzene on Ni(111) , 1982 .

[5]  D. Allara Surface picosecond raman gain spectra of a molecular monolayer , 1980 .

[6]  J. G. Timothy,et al.  Optical detectors for spectroscopy , 1983 .

[7]  W. Knoll,et al.  Surface plasmon enhanced Raman spectra of monolayer assemblies , 1982 .

[8]  K. Ratzlaff Spectrophotometer based on a charge-coupled device photoarray detector , 1980 .

[9]  Kenneth W. Busch,et al.  Guidelines for the Selection of Four Optoelectronic Image Detectors for Low-Light Level Applications , 1983 .

[10]  K. Ratzlaff,et al.  Characterization of a Charge-Coupled Device Photoarray as a Molecular Absorption Spectrophotometric Detector , 1979 .

[11]  W. Knoll,et al.  Surface infrared and surface enhanced Raman vibrational spectra of monolayer assemblies in contact with rough metal surfaces , 1982 .

[12]  R. Miles,et al.  Picosecond surface Raman spectroscopy beyond the damage limit , 1982 .

[13]  P. Avouris,et al.  Multichannel Raman spectroscopy of molecules on evaporated metal films , 1983 .

[14]  R. Dupeyrat,et al.  The Raman study of ultrathin films of barium stearate , 1985 .

[15]  M. F. Tompsett,et al.  Experimental verification of the charge coupled device concept , 1970, Bell Syst. Tech. J..

[16]  Donald H. Gudehus,et al.  The Design and Construction of a Charge-Coupled Device Imaging System , 1985 .

[17]  Jerome D. Swalen,et al.  Integrated optics and Raman scattering: molecular orientation in thin polymer films and Langmuir-Blodgett monolayers , 1982 .

[18]  Y. Talmi,et al.  Self-scanned photodiode array: a multichannel spectrometric detector. , 1980, Applied optics.

[19]  A. R. Tretola,et al.  Stimulated Raman scattering from 20-A layers of silicon on sapphire , 1980 .

[20]  Tsang,et al.  Sub-picosecond time-resolved Raman spectroscopy of LO phonons in GaAs. , 1985, Physical review letters.