Output levelling of renewable energy by electric double-layer capacitor applied for energy storage system

Utilization of renewable energy are coming up from view points of environmental conservation and depletion of fossil fuel. However, the generated power from renewable energies is always fluctuating due to environmental status. Energy storage system is indispensable to compensate these fluctuating components. Energy capacitor system (ECaSS) connected an electric double-layer capacitor (EDLC) with power-electronics devices is useful for the compensation of fluctuating power since one is capable of controlling both active and reactive power simultaneously. This paper proposes the current-source ECaSS (CS-ECS), which consists of EDLC, bi-directional DC-DC converter, and current-source inverter. We have presented the control system for the active/reactive power control of CS-ECS, and have shown the effectiveness of CS-ECS through computer simulations for case of wind power generation system.

[1]  Susumu Yamashiro,et al.  A DEVELOPMENT OF PV-ECS SYSTEM USING A NEW ELECTRICAL ENERGY STORAGE SYSTEM ECS (II) , 1999 .

[2]  Michio Okamura A basic study on power storage capacitor systems , 1996 .

[3]  Yukihiko Sato,et al.  A New Control Strategy to Improve AC Input Current Waveform of Parallel Connected Current Type PWM Rectifiers , 1994 .

[4]  Yoshishige Murakami,et al.  Characteristics of a Current Source AC/DC Converter with Energy Recovery Snubber Circuits and its Multi-Parallel Configuration , 1995 .

[5]  Toshiya Nanahara,et al.  Recent Situation of Wind Power in Foreign Countries and Their Impact on Electric Power System , 2000 .

[6]  Shigeyuki Sugimoto,et al.  Energy storage system utilizing large‐capacity electric double‐layer capacitors for peak‐cut of power demand , 2000 .

[7]  Shigeyuki Sugimoto,et al.  Energy Storage System utilizing Lare Capacity Electric Double-Layer Capacitors for Peak-Cut of Power Demand , 1998 .

[8]  Tokuo Ohnishi,et al.  New PWM Method of Current Fed Type Multi-level Inverter , 1998 .

[9]  K. Harada,et al.  Load leveling using EDLCs under PLL control , 2000, APEC 2000. Fifteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.00CH37058).

[10]  Masaaki Shimizu,et al.  Novel Utility-interactive Electrical Energy Storage System by Electrical Double Layer Capacitors and an Error Tracking Mode PWM Converter , 1998 .

[11]  Luis Bernal Characterization of double-layer capacitors for power electronics applications , 1997 .

[12]  R. Bonert,et al.  Characterization of double-layer capacitors (DLCs) for power electronics applications , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[13]  R. L. Spyker,et al.  Optimization of double layer capacitor arrays , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[14]  Shigeaki Ogawa,et al.  Study on Series-Parallel Changeover Circuit of Capacitor Bank for Energy Storage System Utilizing Electric Double-Layer Capacitors , 2002 .