Energy Dispersive, X‐Ray Fluorescence Analysis

Energy-dispersive X-ray fluorescence (EDXRF) is an analytical method for qualitative as well as quantitative determination of elements in a sample, independent of their chemical form. It is built on the fact that elements that are irradiated with high-energetic X-rays have a certain probability of emitting characteristic X-rays, the energies of which are unique for each element. In the energy-dispersive (ED) systems, the emitted X-rays are detected via their energies. The use of the EDXRF technique has accelerated since the 1960s as a result of the development of liquid nitrogen cooled solid-state detectors, nuclear electronics, and small computers. Nowadays compact light-weight electrically cooled detectors are available, which, together with air-cooled low-power X-ray tubes, are perfectly suited for handheld spectrometers. EDXRF is multielemental and nondestructive and can be applied to large as well as small samples of different composition and character. If conditions are optimized, minimum detection limits can be below the nanogram absolute or micrograms per gram concentration level for small laboratory instruments and into the femtogram or nanograms per milliliter region for more advanced instrumentation (total reflection X-ray fluorescence (TXRF), synchrotron radiation). EDXRF spectrometers exist at many degrees of sophistication, ranging from advanced laboratory instruments to small portable instruments for field observations. They can be designed for analysis of bulk material or for scanning and elemental mapping of small areas. The use of X-ray optics like single or polycapillaries and curved mirrors in Kirkpatrick–Baez geometry lead to X-ray spot sizes of micrometers and below ideally suited for micro-XRF. Mapping with high spatial resolution is thus possible opening investigations down to cell dimension. Typical applications for EDXRF are analysis of agricultural material, medical samples, archaeological and historical objects, painting and fine art objects, and environmental samples such as soil, ores, water, and aerosol particles. Keywords: XRF; EDXRF; micro-XRF; TXRF; synchrotron radiation XRF; X-ray optics; X-ray detectors; quantitative XRF; chemical speciation

[1]  Heike Soltau,et al.  Silicon drift detectors for high count rate X-ray spectroscopy at room temperature , 2001 .

[2]  E. Selin-Lindgren,et al.  Energy‐dispersive X‐ray fluorescence analysis , 2007 .

[3]  H. Sprang,et al.  Determination of light elements using X-ray spectrometry. Part I : Analytical implications of using scattered tube lines , 1998 .

[4]  E. Selin,et al.  Background reduction of x-ray fluorescence spectra in a secondary target energy dispersive spectrometer , 1979 .

[5]  R. Grieken,et al.  X-ray spectrometry : recent technological advances , 2004 .

[6]  Peter Wobrauschek,et al.  Total reflection x‐ray fluorescence analysis—a review , 2007 .

[7]  Birgit Kanngießer,et al.  A new 3D micro X-ray fluorescence analysis set-up - First archaeometric applications , 2003 .

[8]  D. Mcgregor,et al.  Room-temperature compound semiconductor radiation detectors , 1997 .

[9]  A. Karydas,et al.  Calculation of the enhancement of characteristic radiation due to scattering in radioisotope XRF using exact differential cross-sections† , 1993 .

[10]  V. Valković,et al.  Review of recent applications of radioisotope excited X-ray fluorescence , 1993 .

[11]  Eugene P. Bertin,et al.  Principles and Practice of X-Ray Spectrometric Analysis , 1970 .

[12]  G. Falkenberg,et al.  Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L , 2006 .

[13]  B. Hołyńska Sampling and sample preparation in EDXRS , 1993 .

[14]  F. Stross,et al.  High-precision non-destructive x-ray fluorescence method applicable to establishing the provenance of obsidian artifacts , 1993 .

[15]  B. Kanngießer,et al.  Analysis of low Z elements on Si wafer surfaces with synchrotron radiation induced total reflection X-ray fluorescence at SSRL, Beamline 3-3: comparison of droplets with spin coated wafers , 2003 .

[16]  Koen Janssens,et al.  Analysis of X‐ray spectra by iterative least squares (AXIL): New developments , 1994 .

[17]  J. Boman,et al.  Beam profile studies in an x-ray fluorescence spectrometer , 1991 .

[18]  R. D. Giauque A novel method to ascertain sample mass thickness and matrix effects for X-ray fluorescence element determinations , 1994 .

[19]  M. Schieber,et al.  X-Ray Fluorescence Analysis of High Z Materials with Mercuric Iodide Room Temperature Detectors , 1980 .

[20]  P. Pianetta,et al.  Nondestructive dose determination and depth profiling of arsenic ultrashallow junctions with total reflection X-ray fluorescence analysis compared to dynamic secondary ion mass spectrometry , 2004 .

[21]  Ron Jenkins,et al.  Quantitative X-Ray Spectrometry , 1981 .