Impact, runoff and drying of wind-driven rain on a window glass surface: Numerical modelling based on experimental validation

This paper presents a combination of two models to study both the impingement and the contact and surface phenomena of rainwater on a glass window surface: a Computational Fluid Dynamics (CFD) model for the calculation of the distribution of the wind-driven rain (WDR) across the building facade and a semi-empirical droplet-behaviour model. The CFD model comprises the calculation of the wind-flow pattern, the raindrop trajectories and the specific catch ratio as a measure of the WDR falling onto different parts of the facade. The droplet-behaviour model uses the output of the CFD model to simulate the behaviour of individual raindrops on the window glass surface, including runoff, coalescence and drying. The models are applied for a small window glass surface of a two-storey building. It is shown that by far not all WDR that impinges on a glass surface runs off, due to evaporation of drops adhered to the surface. The reduction of runoff by evaporation is 26% for a typical cumuliform rain event and 4% for a typical stratiform rain event. These models can be used to provide the knowledge about WDR impact, runoff and evaporation that is needed for the performance assessment of selfcleaning glass or the study of the leaching of nanoparticles from building facades.

[1]  T. Stathopoulos,et al.  CFD simulation of the atmospheric boundary layer: wall function problems , 2007 .

[2]  T. Shih,et al.  A new k-ϵ eddy viscosity model for high reynolds number turbulent flows , 1995 .

[3]  Dina D'Ayala,et al.  Assessment of wind-driven rain impact, related surface erosion and surface strength reduction of historic building materials , 2012 .

[4]  Hartwig M. Künzel,et al.  Calculation of heat and moisture transfer in exposed building components , 1996 .

[5]  Theodore Stathopoulos,et al.  Application of computational fluid dynamics in building performance simulation for the outdoor environment: an overview , 2011 .

[6]  Jan Carmeliet,et al.  High-resolution wind-driven rain measurements on a low-rise building - Experimental data for model development and model validation , 2005 .

[7]  W. Gujer,et al.  Modelling biocide leaching from facades. , 2011, Water research.

[8]  Jan Hensen,et al.  Application of CFD in Building Performance Simulation for the Outdoor Environment: an Overview , 2011 .

[9]  Dominique Derome,et al.  Rainwater runoff from building facades: A review , 2013 .

[10]  Dominique Derome,et al.  High-resolution CFD simulations for forced convective heat transfer coefficients at the facade of a low-rise building , 2009 .

[11]  Bje Bert Blocken,et al.  A combined CFD–HAM approach for wind-driven rain on building facades , 2007 .

[12]  Henry J. Eldridge,et al.  Common defects in buildings , 1976 .

[13]  Jan Carmeliet,et al.  The influence of the wind-blocking effect by a building on its wind-driven rain exposure , 2006 .

[14]  C. Hall,et al.  Water movement in porous building materials—V. Absorption and shedding of rain by building surfaces , 1982 .

[15]  Theodore Stathopoulos,et al.  CFD evaluation of the wind speed conditions in passages between buildings-effect of wall function roughness modifications on the athmospheric boundary later , 2007 .

[16]  J. Carmeliet,et al.  Overview of three state-of-the-art wind-driven rain assessment models and comparison based on model theory , 2010 .

[17]  Sylvain Coutu,et al.  Modelling wind-driven rain on buildings in urbanized area using 3-D GIS and LiDAR datasets , 2013 .

[18]  Hl Henk Schellen,et al.  Wind-driven rain on the facade of a monumental tower: numerical simulation, full-scale validation and sensitivity analysis , 2009 .

[19]  Jan Carmeliet,et al.  CONSERVATIVE MODELLING OF THE MOISTURE AND HEAT TRANSFER IN BUILDING COMPONENTS UNDER ATMOSPHERIC EXCITATION , 2007 .

[20]  Cliff I. Davidson,et al.  Erosion of limestone building surfaces caused by wind-driven rain: 2. Numerical modeling , 2004 .

[21]  Edmund C.C Choi,et al.  Simulation of wind-driven-rain around a building , 1993 .

[22]  John Straube,et al.  Moisture control and enclosure wall systems , 1998 .

[23]  M Boller,et al.  Synthetic TiO2 nanoparticle emission from exterior facades into the aquatic environment. , 2008, Environmental pollution.

[24]  Jan Carmeliet,et al.  Spatial and temporal distribution of driving rain on a low-rise building , 2002 .

[25]  J. Carmeliet,et al.  On the accuracy of wind-driven rain measurements on buildings , 2006 .

[26]  Jan Carmeliet,et al.  A simplified numerical model for rainwater runoff on building facades: Possibilities and limitations , 2012 .

[27]  Jörg Franke,et al.  The COST 732 Best Practice Guideline for CFD simulation of flows in the urban environment: a summary , 2011 .

[28]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[29]  Steve Sharples,et al.  Full-scale measurements of convective energy losses from exterior building surfaces , 1984 .

[30]  J. Carmeliet,et al.  Validation of CFD simulations of wind-driven rain on a low-rise building facade , 2007 .

[31]  P. Richards,et al.  Appropriate boundary conditions for computational wind engineering models using the k-ε turbulence model , 1993 .

[32]  Jan Carmeliet,et al.  On the validity of numerical wind-driven rain simulation on a rectangular low-rise building under various oblique winds , 2009 .

[33]  P. Bradshaw,et al.  Momentum transfer in boundary layers , 1977 .

[34]  V. Dorer,et al.  Urban Physics: Effect of the micro-climate on comfort, health and energy demand , 2012 .

[35]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[36]  Staf Roels,et al.  Impact, absorption and evaporation of raindrops on building facades , 2009 .

[37]  D. Grawe,et al.  BEST PRACTICE GUIDELINE FOR THE CFD SIMULATION OF FLOWS IN THE URBAN ENVIRONMENT , 2007 .

[38]  Cliff I. Davidson,et al.  Erosion of limestone building surfaces caused by wind-driven rain: 1. Field measurements , 2004 .

[39]  J. Carmeliet,et al.  A review of wind-driven rain research in building science , 2004 .

[40]  Yoshihide Tominaga,et al.  AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings , 2008 .

[41]  Bert Blocken,et al.  CFD evaluation of wind speed conditions in passages between parallel buildings : effect of wall-function roughness modifications for the atmospheric boundary layer flow , 2007 .

[42]  P. Limthongkul,et al.  TiO2 optical coating layers for self-cleaning applications , 2008 .

[43]  V. N. KELKAR,et al.  Size Distribution of Raindrops , 1961, Nature.

[44]  J. Carmeliet,et al.  Laboratory scale studies of biocide leaching from façade coatings , 2012 .

[45]  Dominique Derome,et al.  Numerical simulations of wind-driven rain on an array of low-rise cubic buildings and validation by field measurements , 2014 .

[46]  Bert Blocken,et al.  50 years of Computational Wind Engineering: Past, present and future , 2014 .

[47]  Staf Roels,et al.  Rain water runoff from porous building facades : implementation and application of a first-order runoff model coupled to a HAM model , 2013 .

[48]  Beatriz Rodríguez-Soria,et al.  Combined use of wind-driven rain and wind pressure to define water penetration risk into building façades: The Spanish case , 2013 .