P2P-9 Collective Behavior of cMUT Cells for the Prediction of Electroacoustic Response and Directivity Pattern

This paper describes the development of numerical model of a cMUT array element. The array is modeled in the same way than piezoelectric plates, i.e. using an equivalent linear matrix transfer. Radiation conditions of collective cMUT are discussed, in the baffle plane and far from the baffle. Finally, example of pulse is given and compared with experimental results

[1]  Sylvain Ballandras,et al.  Periodic finite element/boundary element modeling of capacitive micromachined ultrasonic transducers , 2005 .

[2]  G. Lim,et al.  Effects of mutual impedance on the radiation characteristics of transducer arrays. , 2004, The Journal of the Acoustical Society of America.

[3]  F. Teston,et al.  A finite difference model For cMUT devices , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  S.J. Ballandras,et al.  Theoretical analysis of micro-machined ultrasonic transducer using a simple 1-D model , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.