Experimental investigation of zero phase shift effects for Coriolis flowmeters due to pipe imperfections

Abstract Theoretical investigations of a single, straight, vibrating, fluid-conveying pipe have resulted in simple analytical expressions for the approximate prediction of the spatial shift in vibration phase. The expressions have lead to hypotheses for real Coriolis flowmeters (CFMs). To test these, the flexural vibrations of two bent, parallel, non-fluid-conveying pipes are studied experimentally, employing an industrial CFM. Special attention has been paid on the phase shift in the case of zero mass flow, i.e. the zero shift, caused by various imperfections to the “perfect” CFM, i.e. non-uniform pipe damping and mass, and on ambient temperature changes. Experimental observations confirm the hypothesis that asymmetry in the axial distribution of damping will induce zero shifts similar to the phase shifts due to fluid flow. Axially symmetrically distributed damping was observed to influence phase shift at an order of magnitude smaller than the primary effect of mass flow, while small added mass and ambient temperature changes induced zero shifts two orders of magnitude smaller than the phase shifts due to mass flow. The order of magnitude of the induced zero shifts indicates that non-uniform damping, added mass as well as temperature changes could be causes contributing to a time-varying measured zero shift, as observed with some commercial CFMs. The conducted experimental tests of the theoretically based hypotheses have shown that simple mathematical models and approximate analysis allow general conclusions, that may provide a direct insight, and help increasing the benefit of time consuming numerical simulations and laboratory experiments.

[1]  C. Clark,et al.  Experimental determination of the dynamic response of Coriolis mass flow meters , 2006 .

[2]  R. Furness Flow Measurement Handbook , 2001 .

[3]  R. Cheesewright,et al.  THE EFFECT OF FLOW PULSATIONS ON CORIOLIS MASS FLOW METERS , 1998 .

[4]  Manus P. Henry,et al.  The dynamic performance of a new ultra-fast response Coriolis flow meter , 2006 .

[5]  Joseph Shen,et al.  Two-phase flow metering of heavy oil using a Coriolis mass flow meter: A case study , 2006 .

[6]  Tao Wang,et al.  Investigation of the batch measurement errors for single-straight tube Coriolis mass flowmeters , 2006 .

[7]  M. Anklin,et al.  Coriolis mass flowmeters: Overview of the current state of the art and latest research , 2006 .

[8]  J. Kutin,et al.  Theory of errors in Coriolis flowmeter readings due to compressibility of the fluid being metered , 2006 .

[9]  C. Clark,et al.  Understanding the experimental response of Coriolis massflow meters to flow pulsations , 1999 .

[10]  A. Levien,et al.  Effect of detector masses on calibration of Coriolis flowmeters , 1994 .

[11]  I. Bajsić,et al.  An analytical estimation of the Coriolis meter’s characteristics based on modal superposition , 2002 .

[12]  Gerhard Vetter,et al.  Effect of pulsating flow on Coriolis mass flowmeters , 1994 .

[13]  Jonas Dahl,et al.  Analytical predictions for vibration phase shifts along fluid-conveying pipes due to Coriolis forces and imperfections , 2010 .

[14]  C. Clark,et al.  The influence upon Coriolis mass flow meters of external vibrations at selected frequencies , 2003 .

[15]  N. M. Keita Contribution to the understanding of the zero shift effects in Coriolis mass flowmeters , 1989 .

[16]  A. Belhadj,et al.  The dynamic response of Coriolis mass flow meters , 2003 .

[17]  D. Kassoy,et al.  Experimental study of oscillatory motion of particles and bubbles with applications to Coriolis flow meters , 2008 .

[18]  Franz Durst,et al.  Coriolis-effect in mass flow metering , 1991, Archive of Applied Mechanics.

[19]  C. Clark,et al.  The response of Coriolis flowmeters to pulsating flows , 2004 .

[20]  F. Durst,et al.  Effect of a concentrated mass on coriolis flowmetering , 1994 .