Research of Self-Contained Induction Generator Characteristics During Direct Current Consumers Supply

The operating conditions of the induction generator – capacitor bank – rectifier load system have been researched. A harmonic analysis has been performed for currents and voltages of a self-contained induction generator with capacitor excitation when direct current consumers are connected to it. It has been demonstrated that the evaluation of the overload capacity of a selfcontained power supply with an induction generator operating for a direct current consumer is to be made on the basis of the balance of active and reactive powers of all the electromechanical system elements.