Advanced Fault Ride-Through Management Scheme for VSC-HVDC Connecting Offshore Wind Farms

This paper proposes a novel configuration and transient management scheme for Voltage Source Converter-High Voltage Direct Current (VSC-HVDC) connecting Large Scale Wind Farm (LSWF). The proposed configuration aims to fully utilize the HVDC converters with shunt and series reconfiguration during steady state and fault conditions respectively. Thus, it targets the employment of the available converters controls capabilities to enhance the Fault Ride-Through (FRT) performance of the VSC-HVDC and achieve smooth power evacuation to the electric grid. The control strategy is built in such a way to guarantee three factors: 1) enhancing the voltage profile of the electrical grid during symmetrical and asymmetrical grid faults, 2) providing smooth power evacuation from the LSWF, and 3) mitigating the DC link oscillations caused by unbalanced faults. Hence, the proposed scheme demonstrates superior performance of the VSC-HVDC system during steady state and transient conditions. Comprehensive simulation studies are carried out to demonstrate the gorgeous performance of the proposed VSC-HVDC configuration using PSCAD/EMTDC. In addition to that, a lab-scaled experimental set up is constructed to validate the functioning of the proposed VSC-HVDC configuration.

[1]  I. Erlich,et al.  Enhanced Voltage Drop Control by VSC–HVDC Systems for Improving Wind Farm Fault Ridethrough Capability , 2014, IEEE Transactions on Power Delivery.

[2]  Mohamed Shawky El Moursi,et al.  Novel Configuration and Transient Management Control Strategy for VSC-HVDC , 2014, IEEE Transactions on Power Systems.

[3]  Abb Ab,et al.  Large scale Offshore Wind Power Energy evacuation by HVDC Light , 2008 .

[4]  P. Rodriguez,et al.  Negative Sequence Current Control in Wind Power Plants With VSC-HVDC Connection , 2012, IEEE Transactions on Sustainable Energy.

[5]  O Abdel-Baqi,et al.  Series Voltage Compensation for DFIG Wind Turbine Low-Voltage Ride-Through Solution , 2011, IEEE Transactions on Energy Conversion.

[6]  Ronnie Belmans,et al.  Economic comparison of VSC HVDC and HVAC as transmission system for a 300 MW offshore wind farm , 2009 .

[7]  Boon Teck Ooi,et al.  VSC-HVDC station with SSSC characteristics , 2004, IEEE Transactions on Power Electronics.

[8]  A. M. S. Yunus,et al.  Application of UPFC to improve the LVRT capability of wind turbine generator , 2012, 2012 22nd Australasian Universities Power Engineering Conference (AUPEC).

[9]  Dirk Van Hertem,et al.  Multi-terminal VSC HVDC for the European supergrid: Obstacles , 2010 .

[10]  J. Lindgren DOLWIN1 – FURTHER ACHIEVEMENTS IN HVDC OFFSHORE CONNECTIONS , 2013 .

[11]  F. M. Hughes,et al.  Fault ride through of fully rated converter wind turbines with AC and DC transmission systems , 2009 .

[12]  Weidong Xiao,et al.  A novel transient control strategy for VSC-HVDC connecting offshore wind power plant , 2014, 2015 IEEE Power & Energy Society General Meeting.

[13]  Ramón Blasco Giménez,et al.  Efficiency and Fault Ride-Through Performance of a Diode-Rectifier- and VSC-Inverter-Based HVDC Link for Offshore Wind Farms , 2013, IEEE Transactions on Industrial Electronics.

[14]  W.L. Kling,et al.  HVDC Connection of Offshore Wind Farms to the Transmission System , 2007, IEEE Transactions on Energy Conversion.

[15]  Ahmed Massoud,et al.  Unified power flow controller for low voltage ride through capability of wind-based renewable energy grid-connected systems , 2011, Eighth International Multi-Conference on Systems, Signals & Devices.

[16]  Oriol Gomis-Bellmunt,et al.  Optimal control of voltage source converters for fault operation , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[17]  B.T. Ooi,et al.  VSC-HVDC station with SSSC characteristics , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[18]  Brian F. Snyder,et al.  Ecological and economic cost-benefit analysis of offshore wind energy , 2009 .

[19]  Mats Hyttinen,et al.  Challenges on the Road to an Offshore HVDC Grid , 2009 .

[20]  I. Erlich,et al.  Enhanced Fault Ride-Through Method for Wind Farms Connected to the Grid Through VSC-Based HVDC Transmission , 2009, IEEE Transactions on Power Systems.

[21]  Zhe Chen,et al.  Enhanced Control of a DFIG-Based Wind-Power Generation System With Series Grid-Side Converter Under Unbalanced Grid Voltage Conditions , 2013, IEEE Transactions on Power Electronics.

[22]  Mohamed Shawky El Moursi,et al.  Voltage Booster Schemes for Fault Ride-Through Enhancement of Variable Speed Wind Turbines , 2013, IEEE Transactions on Sustainable Energy.

[23]  Dong-Choon Lee,et al.  A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage Restorers , 2011, IEEE Transactions on Energy Conversion.

[24]  Thomas Ackermann,et al.  Loss evaluation of HVAC and HVDC transmission solutions for large offshore wind farms , 2006 .

[25]  Jianguo Zhao,et al.  Faults predictions and analysis on reliability of the ±660kV Ningdong HVDC power transmission system , 2011, 2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT).

[26]  Mehrdad Ghandhari,et al.  A Multi-Option Unified Power Flow Approach for Hybrid AC/DC Grids Incorporating Multi-Terminal VSC-HVDC , 2013, IEEE Transactions on Power Systems.