The Impact of Preprocessing Pipeline Choice in Univariate and Multivariate Analyses of PET Data

It has long been recognized that the data preprocessing chain is a critical part of a neuroimaging experiment. In this work we evaluate the impact of preprocessing choices in univariate and multivariate analyses of Positron Emission Tomography (PET) data. Thirty healthy participants were scanned twice in a High-Resolution Research Tomography PET scanner with the serotonin transporter (5-HTT) radioligand [11 C]DASB. Binding potentials (BPND) from 14 brain regions are quantified with 384 different preprocessing choices. A univariate paired t-test is applied to each region and for each preprocessing choice, and corrected for multiple comparisons using FDR within each pipeline. Additionally, a multivariate Linear Discriminant Analysis (LDA) model is used to discriminate test and retest BPND, and the model performance is evaluated using a repeated cross-validation framework with permutations. The univariate analysis revealed several significant differences in 5-HTT BPND across brain regions, depending on the preprocessing choice. The classification accuracy of the multivariate LDA model varied from 37% to 70% depending on the choice of preprocessing, and could reasonably be modeled with a normal distribution centered at 51% accuracy. In spite of correcting for multiple comparisons, the univariate model with varying preprocessing choices is more likely to generate false-positive results compared to a simple multivariate analysis model evaluated with cross-validation and permutations.

[1]  A. Evans,et al.  Correction for partial volume effects in PET: principle and validation. , 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  Rupert Lanzenberger,et al.  Cerebral serotonin transporter measurements with [11C]DASB: A review on acquisition and preprocessing across 21 PET centres , 2019, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[3]  Bruce Fischl,et al.  Accurate and robust brain image alignment using boundary-based registration , 2009, NeuroImage.

[4]  Andres Hoyos Idrobo,et al.  Assessing and tuning brain decoders: Cross-validation, caveats, and guidelines , 2016, NeuroImage.

[5]  M Slifstein,et al.  Validation and Reproducibility of Measurement of 5-HT1A Receptor Parameters with [carbonyl-11C]WAY-100635 in Humans: Comparison of Arterial and Reference Tissue Input Functions , 2000, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[6]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[7]  Claus Svarer,et al.  Attenuation Correction for the HRRT PET-Scanner Using Transmission Scatter Correction and Total Variation Regularization , 2013, IEEE Transactions on Medical Imaging.

[8]  Jeih-San Liow,et al.  Linearized Reference Tissue Parametric Imaging Methods: Application to [11C]DASB Positron Emission Tomography Studies of the Serotonin Transporter in Human Brain , 2003, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[9]  N. Volkow,et al.  Distribution Volume Ratios without Blood Sampling from Graphical Analysis of PET Data , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[10]  A. Lammertsma,et al.  Simplified Reference Tissue Model for PET Receptor Studies , 1996, NeuroImage.

[11]  Alan A. Wilson,et al.  Positron Emission Tomography Quantification of [11C]-DASB Binding to the Human Serotonin Transporter: Modeling Strategies , 2001, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[12]  Claus Svarer,et al.  Role of Serotonin Transporter Changes in Depressive Responses to Sex-Steroid Hormone Manipulation: A Positron Emission Tomography Study , 2015, Biological Psychiatry.

[13]  Ciprian Catana,et al.  Different partial volume correction methods lead to different conclusions: An 18F-FDG-PET study of aging , 2016, NeuroImage.

[14]  M. Sibomana,et al.  Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[15]  Andrew J. Reader,et al.  Impact of Image-Space Resolution Modeling for Studies with the High-Resolution Research Tomograph , 2008, Journal of Nuclear Medicine.

[16]  Masanori Ichise,et al.  PET imaging of serotonin transporters with [11C]DASB: test-retest reproducibility using a multilinear reference tissue parametric imaging method. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.