Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis

The potential of inertial measurement units (IMUs) for ergonomics applications appears promising. However, previous IMUs validation studies have been incomplete regarding aspects of joints analysed, complexity of movements and duration of trials. The objective was to determine the technological error and biomechanical model differences between IMUs and an optoelectronic system and evaluate the effect of task complexity and duration. Whole-body kinematics from 12 participants was recorded simultaneously with a full-body Xsens system where an Optotrak cluster was fixed on every IMU. Short functional movements and long manual material handling tasks were performed and joint angles were compared between the two systems. The differences attributed to the biomechanical model showed significantly greater (P ≤ .001) RMSE than the technological error. RMSE was systematically higher (P ≤ .001) for the long complex task with a mean on all joints of 2.8° compared to 1.2° during short functional movements. Definition of local coordinate systems based on anatomical landmarks or single posture was the most influent difference between the two systems. Additionally, IMUs accuracy was affected by the complexity and duration of the tasks. Nevertheless, technological error remained under 5° RMSE during handling tasks, which shows potential to track workers during their daily labour.

[1]  Susanne Fuchs-Winkelmann,et al.  Objective assessment, repeatability, and agreement of shoulder ROM with a 3D gyroscope , 2013, BMC Musculoskeletal Disorders.

[2]  Aurelio Cappozzo,et al.  Joint kinematics estimate using wearable inertial and magnetic sensing modules. , 2008, Gait & posture.

[3]  Qingguo Li,et al.  Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics , 2013, Physiological measurement.

[4]  P H Veltink,et al.  Ambulatory measurement of arm orientation. , 2007, Journal of biomechanics.

[5]  F. V. D. van der Helm,et al.  Magnetic distortion in motion labs, implications for validating inertial magnetic sensors. , 2009, Gait & posture.

[6]  James McNames,et al.  Shoulder and Elbow Joint Angle Tracking With Inertial Sensors , 2012, IEEE Transactions on Biomedical Engineering.

[7]  Matthew P. Reed,et al.  Methods for Measuring and Representing Automobile Occupant Posture , 1999 .

[8]  Vladimir M. Zatsiorsky Kinematics of human motion , 1998 .

[9]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[10]  D. Roetenberg,et al.  Xsens MVN: Full 6DOF Human Motion Tracking Using Miniature Inertial Sensors , 2009 .

[11]  Pietro Garofalo,et al.  First in vivo assessment of “Outwalk”: a novel protocol for clinical gait analysis based on inertial and magnetic sensors , 2009, Medical & Biological Engineering & Computing.

[12]  M A Brodie,et al.  Dynamic accuracy of inertial measurement units during simple pendulum motion , 2008, Computer methods in biomechanics and biomedical engineering.

[13]  T. Theologis,et al.  Prediction of the hip joint centre in adults, children, and patients with cerebral palsy based on magnetic resonance imaging. , 2007, Journal of biomechanics.

[14]  David G. Lloyd,et al.  Estimation of the hip joint centre in human motion analysis: a systematic review. , 2015, Clinical biomechanics.

[15]  Sahan Gamage,et al.  New least squares solutions for estimating the average centre of rotation and the axis of rotation. , 2002, Journal of biomechanics.

[16]  A Plamondon,et al.  Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion. , 2007, Applied ergonomics.

[17]  Eduardo Palermo,et al.  Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis , 2014 .

[18]  Antonio I Cuesta-Vargas,et al.  The use of inertial sensors system for human motion analysis , 2010, Physical therapy reviews : PTR.

[19]  A. Opheim,et al.  Evaluating the properties of the coefficient of multiple correlation (CMC) for kinematic gait data. , 2012, Journal of biomechanics.

[20]  Huosheng Hu,et al.  Inertial measurements of upper limb motion , 2006, Medical and Biological Engineering and Computing.

[21]  Silvia Fantozzi,et al.  Assessment of three-dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-magnetic measurement units , 2016, Journal of sports sciences.

[22]  Sunwook Kim,et al.  Performance evaluation of a wearable inertial motion capture system for capturing physical exposures during manual material handling tasks , 2013, Ergonomics.

[23]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[24]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[25]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[26]  Adriano Ferrari,et al.  ‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors , 2009, Medical & Biological Engineering & Computing.

[27]  Gabriele Bleser,et al.  Innovative system for real-time ergonomic feedback in industrial manufacturing. , 2013, Applied ergonomics.

[28]  Laura Rocchi,et al.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors , 2008, Medical & Biological Engineering & Computing.

[29]  Brice Bouvier,et al.  Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations , 2015, Sensors.

[30]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[31]  Michael J. Agnew,et al.  Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion. , 2009, Journal of biomechanical engineering.

[32]  Harvey Weinberg Gyro Mechanical Performance: The Most Important Parameter , 2011 .

[33]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[34]  A. Plamondon,et al.  Optimization of inertial sensor-based motion capturing for magnetically distorted field applications. , 2014, Journal of biomechanical engineering.

[35]  Sakiko Oyama,et al.  Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies , 2016, Ergonomics.