Intraoperative forces and moments analysis on patient head clamp during awake brain surgery
暂无分享,去创建一个
Giancarlo Ferrigno | Elena De Momi | Marco Riva | Danilo De Lorenzo | Enrica Fava | Lorenzo Conti | Emiliano Votta | Lorenzo Bello
[1] Lu-Ping Chao,et al. Shape optimal design and force sensitivity evaluation of six-axis force sensors , 1997 .
[2] Kok-Yong Seng,et al. Neck muscle strength across the sagittal and coronal planes: an isometric study. , 2002, Clinical biomechanics.
[3] E. Camporesi,et al. Patients selection for awake neurosurgery , 2009, HSR proceedings in intensive care & cardiovascular anesthesia.
[4] M. Vavilala,et al. Risks and benefits of patient positioning during neurosurgical care. , 2007, Anesthesiology clinics.
[5] J. Desai. Medical Robotics , 2003 .
[6] Matteo Malosio,et al. The kinematic architecture of the Active Headframe: A new head support for awake brain surgery , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[7] M. Munih,et al. Apparatus to measure simultaneously 14 isometric leg joint moments. Part 1: Design and calibration of six-axis transducers for the forces and moments at the ankle , 2006, Medical & Biological Engineering & Computing.
[8] C. L. Peng,et al. Force measurement on fracture site with external fixation , 2006, Medical and Biological Engineering and Computing.
[9] S. Delp,et al. Three-Dimensional Isometric Strength of Neck Muscles in Humans , 2001, Spine.
[10] R Serramito-García,et al. [Epidural haematoma due to an headrest in an adult]. , 2009, Neurocirugia.
[11] Giancarlo Ferrigno,et al. Force feedback in a piezoelectric linear actuator for neurosurgery , 2011, The international journal of medical robotics + computer assisted surgery : MRCAS.
[12] A R Rezai,et al. Depressed skull fractures in children secondary to skull clamp fixation devices. , 1994, Pediatric neurosurgery.
[13] L.D. Seneviratne,et al. State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery , 2008, IEEE Sensors Journal.
[14] Pierre E Olivier,et al. Isokinetic neck strength profile of senior elite rugby union players. , 2008, Journal of science and medicine in sport.
[15] G. Ferrigno,et al. Technique for the evaluation of derivatives from noisy biomechanical displacement data using a model-based bandwidth-selection procedure , 1990, Medical and Biological Engineering and Computing.
[16] A Rezasoltani,et al. Cervical muscle strength measurement is dependent on the location of thoracic support , 2007, British Journal of Sports Medicine.
[17] Eric L. Lin,et al. The use of the three-pronged Mayfield head clamp resulting in an intracranial epidural hematoma in an adult patient , 2010, European Spine Journal.
[18] H. Duffau. Lessons from brain mapping in surgery for low-grade glioma: insights into associations between tumour and brain plasticity , 2005, The Lancet Neurology.
[19] Karin Wårdell,et al. Stereotactic implantation of deep brain stimulation electrodes: a review of technical systems, methods and emerging tools , 2010, Medical & Biological Engineering & Computing.
[20] Sheng A. Liu,et al. A novel six-component force sensor of good measurement isotropy and sensitivities , 2002 .
[21] A S Mandir,et al. Microelectrode recording and stimulation techniques during stereotactic procedures in the thalamus and pallidum. , 1997, Advances in neurology.
[22] Sherwin E. Hua,et al. Deep Brain Stimulation: An Evolving Technology , 2008, Proceedings of the IEEE.
[23] H. Duffau,et al. Intraoperative electrical stimulation in awake craniotomy: methodological aspects of current practice. , 2010, Neurosurgical focus.
[24] Ana Luisa Trejos,et al. Force sensing and its application in minimally invasive surgery and therapy: A survey , 2010 .
[25] Miguel Gelabert-González,et al. Hematoma epidural secundario al empleo de cabezal autoestático en un adulto , 2009 .