Tibio-femoral joint contact forces in sheep.

Although the sheep has become a standard model for understanding the mechanical conditions that occur after injury and investigating surgical treatments such as osteochondral defect healing and ligament reconstruction, no study has yet evaluated the contact forces that occur in the sheep tibio-femoral joint in vivo. In this study, bone pins, together with reflective markers, were used to measure the 3D kinematics of three sheep hind limbs, simultaneously with the ground reaction forces during repetitions of gait trials. Joint contact forces were then calculated using inverse dynamics and optimisation techniques. Whilst average peak axial tibio-femoral contact forces of 2.1 body weight (BW) were calculated across the 3 sheep, only small medio-lateral and antero-posterior shear forces, averaging 0.7 BW, were determined. Average knee flexion angles ranging from 49 degrees to 70 degrees were observed. From the forces determined in this study, we have provided a better understanding of the mechanical loading environment that occurs in sheep. This has important implications for the interpretation of knee studies in quadrupeds and their relevance to the clinical situation.

[1]  Norbert P Südkamp,et al.  Tendon healing in a bone tunnel. Part II: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep. , 2002, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[2]  D. Lieberman,et al.  Articular area responses to mechanical loading: effects of exercise, age, and skeletal location. , 2001, American journal of physical anthropology.

[3]  A. Weiler,et al.  A model of soft-tissue graft anterior cruciate ligament reconstruction in sheep , 2005, Archives of Orthopaedic and Trauma Surgery.

[4]  William R Taylor,et al.  Tibio‐femoral loading during human gait and stair climbing , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  Ross J. Fox,et al.  A Functional Comparison of Animal Anterior Cruciate Ligament Models to the Human Anterior Cruciate Ligament , 1998, Annals of Biomedical Engineering.

[6]  F. Forriol,et al.  Knee Immobilization on Meniscal Healing After Suture: An Experimental Study in Sheep , 2002, Clinical orthopaedics and related research.

[7]  C. Rubin,et al.  Quantifying the strain history of bone: spatial uniformity and self-similarity of low-magnitude strains. , 2000, Journal of biomechanics.

[8]  A Rohlmann,et al.  A comparison of hip joint forces in sheep, dog and man. , 1984, Journal of biomechanics.

[9]  S J Piazza,et al.  Three-dimensional dynamic simulation of total knee replacement motion during a step-up task. , 2001, Journal of biomechanical engineering.

[10]  David E. Hardt,et al.  Determining Muscle Forces in the Leg During Normal Human Walking—An Application and Evaluation of Optimization Methods , 1978 .

[11]  N. Südkamp,et al.  Tendon healing in a bone tunnel. Part II , 2002 .

[12]  U. Bosch,et al.  Healing of the patellar tendon autograft after posterior cruciate ligament reconstruction— a process of ligamentization? , 1992, The American journal of sports medicine.

[13]  M. Akens,et al.  The use of photooxidized, mushroom-structured osteochondral grafts for cartilage resurfacing--a comparison to photooxidized cylindrical grafts in an experimental study in sheep. , 2004, Osteoarthritis and cartilage.

[14]  P. Evans,et al.  Manual punch versus power harvesting of osteochondral grafts. , 2004, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[15]  M G Pandy,et al.  Static and dynamic optimization solutions for gait are practically equivalent. , 2001, Journal of biomechanics.

[16]  V. Baltzopoulos Muscular and tibiofemoral joint forces during isokinetic concentric knee extension. , 1995, Clinical biomechanics.

[17]  Roy D. Crowninshield,et al.  Use of Optimization Techniques to Predict Muscle Forces , 1978 .

[18]  U Rehder,et al.  [A CAE (computer aided engineering) approach to dynamic whole body modeling--the forces iin the lumbar spine in asymmetrical lifting]. , 1995, Biomedizinische Technik. Biomedical engineering.

[19]  Charles Hansen,et al.  The Visualization Handbook , 2011 .

[20]  A Rohlmann,et al.  Hip joint forces in sheep. , 1999, Journal of biomechanics.

[21]  S. Woo,et al.  Interspecies variation of compressive biomechanical properties of the meniscus. , 1995, Journal of biomedical materials research.

[22]  Paul Dierckx,et al.  Curve and surface fitting with splines , 1994, Monographs on numerical analysis.

[23]  E. Kellis Tibiofemoral joint forces during maximal isokinetic eccentric and concentric efforts of the knee flexors. , 2001, Clinical biomechanics.

[24]  G. Deuretzbacher,et al.  Ein CAE-basierter Zugang zur dynamischen Ganzkörpermodellierung - Die Kräfte in der lumbalen Wirbelsäule beim asymmetrischen Heben - A CAE based Approach to Dynamic Whole-body Modelling - the Forces Acting on the Lumbar Spine During Asymmetric Lifting , 1995 .

[25]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[26]  R. Brand,et al.  Comparison of hip force calculations and measurements in the same patient. , 1994, The Journal of arthroplasty.

[27]  Daniel E Lieberman,et al.  Predicting long bone loading from cross-sectional geometry. , 2004, American journal of physical anthropology.

[28]  Hans-Christian Hege,et al.  amira: A Highly Interactive System for Visual Data Analysis , 2005, The Visualization Handbook.

[29]  L E Lanyon,et al.  Bone strain in the tibia during normal quadrupedal locomotion. , 1970, Acta orthopaedica Scandinavica.

[30]  F. Forriol,et al.  Articular cartilage degeneration after frozen meniscus and Achilles tendon allograft transplantation: experimental study in sheep. , 2003, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[31]  G. Bergmann,et al.  Musculo-skeletal loading conditions at the hip during walking and stair climbing. , 2001, Journal of biomechanics.

[32]  D L Butler,et al.  In vivo forces in the anterior cruciate ligament: direct measurements during walking and trotting in a quadruped. , 1994, Journal of biomechanics.

[33]  D T Davy,et al.  An investigation of muscle lines of action about the hip: a centroid line approach vs the straight line approach. , 1975, Journal of biomechanics.

[34]  L Claes,et al.  Analysis of inter-fragmentary movement as a function of musculoskeletal loading conditions in sheep. , 1997, Journal of biomechanics.

[35]  N. Zheng,et al.  An analytical model of the knee for estimation of internal forces during exercise. , 1998, Journal of biomechanics.

[36]  K N An,et al.  Determination of muscle and joint forces: a new technique to solve the indeterminate problem. , 1984, Journal of biomechanical engineering.