CD-AFM reference metrology at NIST and SEMATECH

The National Institute of Standards and Technology (NIST) and SEMATECH have been working together to improve the traceability of critical dimension atomic force microscope (CD-AFM) dimensional metrology in semiconductor manufacturing. A major component of this collaboration has been the implementation of a Reference Measurement System (RMS) at SEMATECH using a current generation CD-AFM. An earlier tool, originally used at SEMATECH, has now been installed at NIST. Uncertainty budgets were developed for pitch, height, and CD measurements using both tools. At present, the standard uncertainties are approximately 0.2 % for pitch measurements and 0.4% for step height measurements. Prior to the current work, CD AFM linewidth measurements were limited to a standard uncertainty of about 5 nm. However, this limit can now be significantly reduced. This reduction results from the completion of the NIST/SEMATECH collaboration on the development of single crystal critical dimension reference materials (SCDDRM). A new generation of these reference materials was released to SEMATECH Member Companies during late 2004. The SEMATECH RMS was used to measure the linewidths of selected features on the distributed specimens. To reduce the uncertainty in tip width calibration, a separate transfer experiment was performed in which samples were measured by CD-AFM and then sent for high resolution transmission electron microscopy (HRTEM). In this manner, CD-AFM could be used to transfer the HRTEM width information to the distributed samples. Consequently, we are now able to reduce the limit on the standard uncertainty (k = 1) of CD-AFM width measurements to 1 nm.

[1]  Richard A. Allen,et al.  CD Reference Materials for Sub-Tenth Micrometer Applications , 2002 .

[2]  Charles N. Archie,et al.  Reducing measurement uncertainty drives the use of multiple technologies for supporting metrology , 2004, SPIE Advanced Lithography.

[3]  Ndubuisi G. Orji,et al.  Silicon single atom steps as AFM height standards , 2001, SPIE Advanced Lithography.

[4]  Jeremiah R. Lowney,et al.  Scanning electron microscope analog of scatterometry , 2002, SPIE Advanced Lithography.

[5]  Ronald G. Dixson,et al.  Reference metrology using a next-generation CD-AFM , 2004, SPIE Advanced Lithography.

[6]  J. Villarrubia Algorithms for Scanned Probe Microscope Image Simulation, Surface Reconstruction, and Tip Estimation , 1997, Journal of research of the National Institute of Standards and Technology.

[7]  Martin E. Mastovich,et al.  Electron Beam Metrology of 193 nm Resists at Ultra Low Voltage | NIST , 2003 .

[8]  Richard A. Allen,et al.  Critical Dimension Reference Features with Sub-Five Nanometer Uncertainty , 2005 .

[9]  Jeremiah R. Lowney,et al.  Edge determination for polycrystalline silicon lines on gate oxide , 2001, SPIE Advanced Lithography.

[10]  Marylyn Hoy Bennett,et al.  Implementation of Reference Measurement System using CD-AFM , 2003, SPIE Advanced Lithography.

[11]  Charles N. Archie,et al.  Characteristics of accuracy for CD metrology , 1999, Advanced Lithography.

[12]  Barry N. Taylor,et al.  Guidelines for Evaluating and Expressing the Uncertainty of Nist Measurement Results , 2017 .

[13]  Michael T. Postek,et al.  Simulation study of repeatability and bias in the CD-SEM , 2003, SPIE Advanced Lithography.

[14]  Wei Chu,et al.  An image stitching method to eliminate the distortion of the sidewall in linewidth measurement , 2004, SPIE Advanced Lithography.

[15]  Michael T. Postek,et al.  Toward traceability for at-line AFM dimensional metrology , 2002, SPIE Advanced Lithography.

[16]  Richard A. Allen,et al.  Critical Dimension Calibration Standards for ULSI Metrology , 2003 .

[17]  Kenneth W. Tobin,et al.  Preliminary results for mask metrology using spatial heterodyne interferometry , 2003, SPIE Photomask Technology.

[18]  Michael Bishop,et al.  Specifications and methodologies for benchmarking of advanced CD-SEMs at the 90-nm CMOS technology node and beyond , 2003, SPIE Advanced Lithography.

[19]  Michael Bishop,et al.  Benchmarking of advanced CD-SEMs at the 130-nm CMOS technology node , 2002, SPIE Advanced Lithography.

[20]  Xuezeng Zhao,et al.  A Model for Step Height, Edge Slope and Linewidth Measurements Using AFM , 2003 .