Flow characteristics of wire-rod type electrohydrodynamic gas pump under negative corona operations

Abstract The electrohydrodynamic (EHD) flow characteristics for a wire to rod type EHD gas pump have been experimentally investigated for pipe diameter sizes of 6.5, 10, and 20 mm. Experiments were conducted for dc negative applied voltage ranging from 0 to 24 kV applied between a corona wire with a diameter of 0.24 mm and a grounded rod electrode. The grounded rod electrode diameter is varied from 1.5 to 3.1 mm. The wire/rod electrode distance to pipe diameter ratio is varied from 0.63 to 1.16. The results show that gas flow rate increases with increasing EHD number or discharge current. A maximum of 40.1 L/min of gas flow rate is generated for a pipe diameter of 20 mm, with a grounding rod diameter electrode of 3.1 mm and corona wire to grounding rod electrode gap distant of 12.6 mm.

[1]  Jen-Shih Chang,et al.  Electromagnetic hydrodynamics , 1994 .

[2]  Hidekatsu Fujishima,et al.  Three-dimensional EHD simulation for point corona electrostatic precipitator based on laminar and turbulent models , 2006 .

[3]  T. Yamamoto,et al.  Three-dimensional ionic wind and electrohydrodynamics of tuft/point corona electrostatic precipitator , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[4]  Lin Zhao,et al.  EHD flow in air produced by electric corona discharge in pin–plate configuration , 2005 .

[5]  Hidekatsu Fujishima,et al.  Electrohydrodynamics of spiked electrode electrostatic precipitators , 2004 .

[6]  Haim Kalman,et al.  Experimental optimization of an electric blower by corona wind , 2002 .

[7]  M. Rickard,et al.  Maximizing ion-driven gas flows , 2006 .

[8]  Image analysis of gas-phase EHD flow field for needle-plane electrode system , 2003, 2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.

[9]  J. Mizeraczyk,et al.  Numerical modeling of near corona wire electrohydrodynamic flow in a wire-plate electrostatic precipitator , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Jen-Shih Chang,et al.  Electrohydrodynamically induced flow direction in a wire-non-parallel plate electrode corona discharge , 2007 .

[11]  F. C. Lai,et al.  EHD-enhanced drying with multiple needle electrode , 2005 .

[12]  Jerzy Mizeraczyk,et al.  Measurements of the velocity field of the flue gas flow in an electrostatic precipitator model using PIV method , 2001 .

[13]  T. Yamamoto,et al.  Electrohydrodynamics in an electrostatic precipitator , 1981, Journal of Fluid Mechanics.

[14]  A. P. Chattock XLIV. On the velocity and mass of the ions in the electric wind in air , 1899 .

[15]  Jen-Shih Chang,et al.  Flow characteristics of dc wire-non-parallel plate electrohydrodynamic gas pumps , 2008 .

[16]  Jerzy Mizeraczyk,et al.  On-set of EHD turbulence for cylinder in cross flow under corona discharges , 2006 .

[17]  Jen-Shih Chang,et al.  Corona discharge processes , 1991 .