Simultaneous determination of Cd, Pb, and Cu metal trace concentrations in water certified samples and soil extracts by means of Hg-electroplated-Ir microelectrode array based sensors

Abstract Mercury-electroplated-iridium microelectrode array based sensors were successfully used for the simultaneous determination of Cd, Pb and Cu trace concentrations by means of square wave anodic stripping voltammetry (SWASV). These recently developed sensors consist of an array of (42×42) 6-μm-diameter iridium microdiscs onto which Hg microdrops are electroplated. The Ir microdisc arrays were achieved by using microfabrication processing techniques and a Hg charge of 15 mC was identified to be the optimum amount to be electroplated onto the 6-μm-diameter microdisc array. The microelectrode array based sensors were used to analyze both water certified samples covering a wide range of metal concentrations (from 1 to ∼1000 ppb) and soil extracts collected at different soil depths (from the surface to about 1 m depth in the Rouyn-Noranda region, Que., Canada). Different physico-chemical forms of the three metals were extracted from the soil samples using barium chloride, sodium pyrophosphate and oxalic acid/ammonium oxalate solvents. For the water samples, the measured Cd, Pb and Cu concentrations are found to be in a good agreement with the certified values (with an averaged recovery for the three elements of (103±15)%). On the other hand, all the Cd forms extracted from the soil are found to be ASV-electroactive since a satisfactory agreement was obtained between the concentrations measured by SWASV and those determined by means of graphite furnace atomic absorption spectrometry (GFAAS). While Pb and Cu concentration profiles in soil were found to be particularly dependent on the extractant used, Cd concentration profile exhibited the same trend for the three extractants. The differences in metal concentrations between extractants are discussed and the predominant physico-chemical metal forms are established as a function of the horizon in the soil profile. Finally, the developed SWASV sensors are shown to be successful to measure reliably metal concentrations as low as 50 ppt in soil extracts with a preconcentration time of only 10 min.

[1]  M. Yamazaki,et al.  Use of an ultrafiltration and gamma‐ray irradiation technique for studying the speciation of trace elements in river waters , 1996 .

[2]  M. McBride,et al.  Long-term leaching of trace elements in a heavily sludge-amended silty clay loam soil , 1999 .

[3]  A. Bond Past, present and future contributions of microelectrodes to analytical studies employing voltammetric detection. A review , 1994 .

[4]  Denise Krulic,et al.  Multiple square wave voltammetry: experimental verification of the theory , 1990 .

[5]  M. R. Carter,et al.  Soil Sampling and Methods of Analysis , 1993 .

[6]  J. Garnier,et al.  Distribution of Trace Elements Associated with Dissolved Compounds (<0.45 μm−1 nm) in Freshwater Using Coupled (Frontal Cascade) Ultrafiltration and Chromatographic Separations , 1998 .

[7]  Gregory T. A. Kovacs,et al.  Field Evaluation of an Electrochemical Probe for in Situ Screening of Heavy Metals in Groundwater , 1998 .

[8]  D. Burns,et al.  Statistics for analytical chemistry (2nd edn): By J. C. Miller and J. N. Miller. Pp. 227. Ellis Horwood, Chichester. 1988. Paperback £9.95 , 1988 .

[9]  M. Shafer,et al.  Trace Metal Levels and Partitioning in Wisconsin Rivers , 1994 .

[10]  Gregory T. A. Kovacs,et al.  Iridium-Based Ultramicroelectrode Array Fabricated by Microlithography , 1994 .

[11]  M. Khakani,et al.  Mercury-electroplated-iridium microelectrode array based sensors for the detection of heavy metal ultratraces: optimization of the mercury charge , 1999 .

[12]  S. Sauvé,et al.  Copper Solubility and Speciation of In Situ Contaminated Soils: Effects of Copper Level, pH and Organic Matter , 1997 .

[13]  K. Killham,et al.  Determination of acute Zn toxicity in pore water from soils previously treated with sewage sludge using bioluminescence assays , 1999 .

[14]  M. Khakani,et al.  Development of Hg-electroplated-iridium based microelectrode arrays for heavy metal traces analysis , 1999 .

[15]  W. Pickering,et al.  The influence of pH and complex formation on the ASV peaks of Pb, Cu and Cd. , 1980, Talanta.

[16]  Jacques Buffle,et al.  Antifouling Membrane-Covered Voltammetric Microsensor for in Situ Measurements in Natural Waters , 1996 .

[17]  P. Worsfold,et al.  Cadmium: toxicology and analysis. A review. , 1991, The Analyst.

[18]  B. Welz Atomic absorption spectrometry , 1985 .

[19]  J. Osteryoung,et al.  Iridium-based small mercury electrodes , 1987 .

[20]  M. Hojo,et al.  Speciation of Arsenic in Natural Waters by Solvent Extraction and Hydride Generation Atomic Absorption Spectrometry , 1994 .

[21]  R. Hintsche,et al.  Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays , 1997 .

[22]  Milena Koudelka-Hep,et al.  Gel integrated microelectrode arrays for direct voltammetric measurements of heavy metals in natural waters and other complex media , 1998 .

[23]  N. Kasthurikrishnan,et al.  Flow injection Donnan dialysis preconcentration of trace metal cations for inductively coupled plasma atomic emission spectrometry , 1993 .

[24]  J. Osterloh,et al.  Determination of lead in blood by square wave anodic stripping voltammetry at a carbon disk ultramicroelectrode. , 1994, Analytical chemistry.

[25]  T. Florence,et al.  Electrochemical approaches to trace element speciation in waters , 1986 .

[26]  R. Lavado,et al.  Concentration and distribution of extractable elements in a soil as affected by tillage systems and fertilization , 1999 .

[27]  M. Baldo,et al.  Determination of heavy metals in real samples by anodic stripping voltammetry with mercury microelectrodes : Part 1. Application to Wine , 1989 .

[28]  S. Kounaves,et al.  FAILURE ANALYSIS OF MICROFABRICATED IRIDIUM ULTRAMICROELECTRODES IN CHLORIDE MEDIA , 1998 .

[29]  C. Stalikas,et al.  Use of a sequential extraction scheme with data normalisation to assess the metal distribution in agricultural soils irrigated by lake water , 1999 .

[30]  William H. Hendershot,et al.  Speciation of Lead in Contaminated Soils , 1997 .

[31]  Tsuguyoshi Suzuki,et al.  Toxicology of metals , 1996 .

[32]  M. I. Montenegro,et al.  Microelectrodes : theory and applications , 1991 .

[33]  Milena Koudelka-Hep,et al.  Mercury-Plated Iridium-Based Microelectrode Arrays for Trace Metals Detection by Voltammetry: Optimum Conditions and Reliability , 1996 .

[34]  T. H. Christensen,et al.  Speciation of dissolved cadmium: Interpretation of dialysis, ion exchange and computer (GEOCHEM) methods , 1995 .

[35]  J. Chappell,et al.  Speciation of arsenic in a contaminated soil by solvent extraction. , 1995, Talanta.

[36]  J. Buffle,et al.  An iridium-based mercury-film electrode: Part I. Selection of substrate and preparation , 1987 .