Design and performance comparisons of two multidrive systems with unity power factor

From economical aspects, the multidrive systems are a promising application area for the converters, where the cost and size of the converters are shared by multiple inverter-motors. Given terminal constraints of unity power factor in grid line and independent multiple motor controls in output ports, two multidrive topologies are possible: one with single PWM-VSR feeding inverters through the common dc bus, and the other using a diode rectifier and an active power filter with its own load. Despite several publications for two systems, the features and advantages of the two systems have not been clearly explained. This paper, in detail, presents the theoretical analyses and systematic comparisons of the two multidrive topologies, from converter kilovolt-ampere ratings, dc-link voltage requirements, switch ratings, semiconductor losses, and reactive component designs point of views.

[1]  Ralph Teichmann,et al.  Design and loss comparison of matrix converters, and voltage-source converters for modern AC drives , 2002, IEEE Trans. Ind. Electron..

[2]  J. H. Marks,et al.  Ratings analysis of active power filters , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[3]  F. Abrahamsen,et al.  Adjustable speed drive with active filtering capability for harmonic current compensation , 1995, Proceedings of PESC '95 - Power Electronics Specialist Conference.

[4]  Wale Risorgimento Stand-alone AC/DC Converter for Multiple Inverter Applications , 1996 .

[5]  S. Ponnaluri,et al.  Generalized system design and analysis of PWM based power electronic converters , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[6]  Juan Dixon,et al.  A fuzzy-controlled active front-end rectifier with current harmonic filtering characteristics and minimum sensing variables , 1999 .

[7]  R. Stephenson A and V , 1962, The British journal of ophthalmology.

[8]  D. Nakajima,et al.  A three-phase voltage-type PWM rectifier with the function of an active power filter , 2000 .

[9]  Romeo Sanchez,et al.  DSP based intersectional control in multidrive systems , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[10]  Mariusz Malinowski,et al.  Direct power control for three-phase PWM rectifier with active filtering function , 2003 .

[11]  W. M. Grady,et al.  Survey of active power line conditioning methodologies , 1990 .

[12]  Geza Joos,et al.  A performance comparison of PWM rectifiers and synchronous link converters , 1994, IEEE Trans. Ind. Electron..

[13]  Subhashish Bhattacharya,et al.  Active filter system implementation , 1998 .

[14]  Cyril W. Lander Power electronics, 2nd ed. , 1987 .

[15]  G. Joos,et al.  Design and performance of active power filters , 1998 .

[16]  F. Blaabjerg,et al.  A new cost-effective multi-drive solution based on a two-stage direct power electronic conversion topology , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).