ASDIN Original Investigations: Inflow Reduction by Distalization of Anastomosis Treats Efficiently High‐Inflow High‐Cardiac Output Vascular Access for Hemodialysis

The arteriovenous fistula used for vascular access for hemodialysis may contribute to development of congestive heart failure. Theses patients can present with frequent episodes of congestive hear failure. Traditional management of high‐inflow, a high‐cardiac‐output fistula generally involves either closure or banding. Although high‐output state can be controlled, the lifeline of the patient is lost. We describe a series of 17 hemodialysis patients (10 men and 7 women) in whom a novel inflow reduction method was employed. All patients had symptoms of heart failure (15 brachiocephalic fistulas and two brachioaxillary bypass grafts) and a fistula inflow rate above 1600 ml/min. The inflow reduction procedure included ligation of the brachial anastomosis and reconstruction of the fistula by using an expanded polytetrafluoroethylene (Gore‐Tex Intering) vascular graft in a bypass from the radial artery. The mean (± SD) time between fistula creation and the inflow reduction procedure was 30 ± 17 months. The mean access inflow rate decreased significantly after the inflow reduction procedure, from 3135 ± 692 to 1025 ± 551 ml/min (p =0.0001). The mean cardiac output rate decreased from 8 ± 3.1 to 5.6 ± 1.7 l/min (p = 0.001) with resolution of symptoms. During the follow‐up period thrombosis or stenosis developed in seven patients, three of whom underwent surgical revision. Thirteen of the seventeen accesses (77%) subjected to the inflow reduction procedure remained patent. Access loss was due to failed fistuloplasty or thrombosis. To our knowledge, this is the first report demonstrating that inflow reduction obtained by distalization of the anastomosis of the access fistula is feasible and safe for managing high‐inflow, high‐cardiac‐output fistulas. Longer and larger studies of the inflow reduction procedure and its benefits are needed.

[1]  J. Spears,et al.  Case report: recurrent heart failure with preserved ejection fraction but markedly elevated BNP in a 51-year-old female on hemodialysis with oversized AV fistula. , 2006, International journal of cardiology.

[2]  Nils R Planken,et al.  The relation between vascular access flow and different types of vascular access with systemic hemodynamics in hemodialysis patients. , 2005, Artificial organs.

[3]  A. Matsumoto,et al.  Banding a hemodialysis arteriovenous fistula to decrease blood flow and resolve high output cardiac failure: Report of a case , 2005, Surgery Today.

[4]  B. Murray,et al.  Effect of surgical banding of a high-flow fistula on access flow and cardiac output: intraoperative and long-term measurements. , 2004, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[5]  S. Pandeya,et al.  Arteriovenous fistula-associated high-output cardiac failure: a review of mechanisms. , 2004, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[6]  A. Sassano,et al.  The impact of arteriovenous fistula formation on central hemodynamic pressures in chronic renal failure patients: a prospective study. , 2002, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[7]  S. Pandeya,et al.  The relationship between cardiac output and access flow during hemodialysis. , 1999, ASAIO journal.

[8]  P. R. Young,et al.  High-output cardiac failure secondary to a brachiocephalic arteriovenous hemodialysis fistula: two cases. , 1998, The American surgeon.

[9]  I. Engelberts,et al.  High-output cardiac failure due to excessive shunting in a hemodialysis access fistula: an easily overlooked diagnosis. , 1995, American journal of nephrology.

[10]  A. Timmis,et al.  The influence of hemodialysis fistulas on circulatory dynamics and left ventricular function. , 1982, The International journal of artificial organs.

[11]  H. Gurland,et al.  The effects of arteriovenous shunts on cardiac function in renal dialysis patients--an echocardiographic evaluation. , 1978, Clinical nephrology.

[12]  H. Harter,et al.  Cardiac failure and upper extremity arteriovenous dialysis fistulas. Case reports and a review of the literature. , 1976, Archives of internal medicine.

[13]  J. Maher,et al.  Heart failure as a complication of hemodialysis arteriovenous fistula. , 1972, Annals of internal medicine.