Descemet Stripping Endothelial Keratoplasty: Six-Month Results of the First 100 Consecutive Surgeries Performed Solo by a Surgeon Using 1 Technique With 100% Follow-up

Purpose: To determine the outcomes and complication rates achieved by a novice cornea surgeon when performing Descemet stripping automated endothelial keratoplasty (DSAEK) while precisely following a previously described forceps insertion technique. Methods: Prospective, noncomparative interventional case series including 100 eyes of 74 patients with endothelial decompensation. An institutional review board approved, prospective, DSAEK series was initiated. Cases included all initial patients with endothelial failure operated on by a single surgeon after his cornea fellowship training. The surgeon strictly adhered to a previously published 5-mm incision, folded forceps graft insertion technique. Patients were followed at 1 day, 1 week, and 1, 3, and 6 months. Postoperative complications (including graft dislocation, primary graft failure, and pupillary block), best spectacle-corrected visual acuity (BSCVA) and specular microscopy of central endothelial cell density at 6 months postoperatively were the main outcome measures. Results: One hundred consecutive eyes were enrolled in the study, and 100% follow-up at 6 months was achieved. Postoperative complications included 2 graft dislocations (2%), and both grafts were attached successfully and cleared; 2 episodes of cystoid macular edema (2%) occurred, and 1 eye (1%) developed areas of anterior iris synechiae to the graft. There were no pupillary block episodes or primary graft failures. In eyes without comorbidity (n = 57), the mean BSCVA improved from 20/48 preoperation to 20/29 at 6 months after operation (P < 0.001). No eyes lost vision. Mean central endothelial cell density decreased from 2769 cells per square millimeter preoperatively to 2308 cells per square millimeter postoperatively at 6 months. This represented a mean cell loss of 16%. Conclusions: This study demonstrates that with meticulous attention to a standardized forceps insertion technique, excellent outcomes with low rates of complications, improved BSCVA, and low endothelial cell loss can be achieved with DSAEK surgery.

[1]  Paolo Brusini,et al.  Comparison Between Laser Scanning In Vivo Confocal Microscopy and Noncontact Specular Microscopy in Assessing Corneal Endothelial Cell Density and Central Corneal Thickness , 2011, Cornea.

[2]  David A. Price,et al.  Descemet's stripping endothelial keratoplasty five-year graft survival and endothelial cell loss. , 2011, Ophthalmology.

[3]  K. Goins,et al.  Comparison of Bifold Forceps and Cartridge Injector Suture Pull-through Insertion Techniques for Descemet Stripping Automated Endothelial Keratoplasty , 2011, Cornea.

[4]  K. Walter,et al.  Three-Millimeter Incision Descemet Stripping Endothelial Keratoplasty Using Sodium Hyaluronate (Healon): A Survey of 105 Eyes , 2011, Cornea.

[5]  M. Terry,et al.  Endothelial Cell Damage in Descemet Stripping Automated Endothelial Keratoplasty With the Underfold Technique: 6- and 12-Month Results , 2010, Cornea.

[6]  S. Debanne,et al.  Effect of Incision Width on Graft Survival and Endothelial Cell Loss After Descemet Stripping Automated Endothelial Keratoplasty , 2010, Cornea.

[7]  S. Debanne,et al.  Descemet's stripping automated endothelial keratoplasty outcomes compared with penetrating keratoplasty from the Cornea Donor Study. , 2010, Ophthalmology.

[8]  Roni M. Shtein,et al.  Ophthalmic Technology Assessment Descemet ’ s Stripping Endothelial Keratoplasty : Safety and Outcomes , 2022 .

[9]  M. Terry,et al.  Endothelial keratoplasty: vision, endothelial survival, and complications in a comparative case series of fellows vs attending surgeons. , 2009, American journal of ophthalmology.

[10]  G. Melles,et al.  Simple technique for graft insertion in Descemet‐stripping (automated) endothelial keratoplasty using a 30‐gauge needle , 2009, Journal of cataract and refractive surgery.

[11]  M. Terry,et al.  Endothelial keratoplasty for Fuchs' dystrophy with cataract: complications and clinical results with the new triple procedure. , 2009, Ophthalmology.

[12]  M. Terry,et al.  Precut tissue for Descemet's stripping automated endothelial keratoplasty: vision, astigmatism, and endothelial survival. , 2009, Ophthalmology.

[13]  M. Terry,et al.  Endothelial Keratoplasty: The Influence of Preoperative Donor Endothelial Cell Densities on Dislocation, Primary Graft Failure, and 1-Year Cell Counts , 2008, Cornea.

[14]  J. Mehta,et al.  Comparison of donor insertion techniques for descemet stripping automated endothelial keratoplasty. , 2008, Archives of ophthalmology.

[15]  W. Culbertson,et al.  Complications of Descemet's stripping with automated endothelial keratoplasty: survey of 118 eyes at One Institute. , 2008, Ophthalmology.

[16]  V. Scorcia,et al.  A modified technique for descemet membrane stripping automated endothelial keratoplasty to minimize endothelial cell loss. , 2008, Archives of ophthalmology.

[17]  V. Sarnicola,et al.  Descemet-stripping Automated Endothelial Keratoplasty by Using Suture for Donor Insertion , 2008, Cornea.

[18]  M. Terry,et al.  Endothelial Keratoplasty: A Simplified Technique to Minimize Graft Dislocation, Iatrogenic Graft Failure, and Pupillary Block , 2008 .

[19]  K. Goins,et al.  Eye bank survey of surgeons using precut donor tissue for descemet stripping automated endothelial keratoplasty. , 2008, Cornea.

[20]  I. Bahar,et al.  Suture-assisted vs forceps-assisted insertion of the donor lenticula during Descemet stripping automated endothelial keratoplasty. , 2008, American journal of ophthalmology.

[21]  F. Price,et al.  Endothelial cell loss after descemet stripping with endothelial keratoplasty influencing factors and 2-year trend. , 2008, Ophthalmology.

[22]  H. van Cleynenbreugel,et al.  Graft insertion during Descemet‐stripping automated endothelial keratoplasty: Pulling the graft inward , 2008, Journal of cataract and refractive surgery.

[23]  M. Terry,et al.  Endothelial cell loss after Descemet's stripping endothelial keratoplasty in a large prospective series. , 2008, Ophthalmology.

[24]  M. Terry Endothelial keratoplasty: clinical outcomes in the two years following deep lamellar endothelial keratoplasty (an American Ophthalmological Society thesis). , 2007, Transactions of the American Ophthalmological Society.

[25]  F. Price,et al.  Descemet's stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. , 2005, Journal of refractive surgery.

[26]  M. Terry,et al.  Endothelial Replacement Without Surface Corneal Incisions or Sutures: Topography of the Deep Lamellar Endothelial Keratoplasty Procedure , 2001, Cornea.

[27]  P. Binder,et al.  Posterior lamellar keratoplasty for a case of pseudophakic bullous keratopathy. , 1999, American journal of ophthalmology.