Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device.

An important challenge facing the design of turbodynamic ventricular assist devices (VADs) intended for long-term support is the optimization of the flow path geometry to maximize hydraulic performance while minimizing shear-stress-induced hemolysis and thrombosis. For unshrouded centrifugal, mixed-flow and axial-flow blood pumps, the complex flow patterns within the blade tip clearance between the lengthwise upper surface of the rotating impeller blades and the stationary pump housing have a dramatic effect on both the hydrodynamic performance and the blood damage production. Detailed computational fluid dynamics (CFD) analyses were performed in this study to investigate such flow behavior in blade tip clearance region for a centrifugal blood pump representing a scaled-up version of a prototype pediatric VAD. Nominal flow conditions were analyzed at a flow rate of 2.5 L/min and rotor speed of 3000 rpm with three blade tip clearances of 50, 100, and 200 microm. CFD simulations predicted a decrease in the averaged tip leakage flow rate and an increase in pump head and axial thrust with decreasing blade tip clearances from 200 to 50 microm. The predicted hemolysis, however, exhibited a unimodal relationship, having a minimum at 100 microm compared to 50 microm and 200 microm. Experimental data corroborate these predictions. Detailed flow patterns observed in this study revealed interesting fluid dynamic features associated with the blade tip clearances, such as the generation and dissipation of tip leakage vortex and its interaction with the primary flow in the blade-blade passages. Quantitative calculations suggested the existence of an optimal blade tip clearance by which hydraulic efficiency can be maximized and hemolysis minimized.

[1]  Kazumitsu Sekine,et al.  Computational fluid dynamics analysis of an intra-cardiac axial flow pump. , 2003, Artificial organs.

[2]  A. Goto Study of Internal Flows in a Mixed-Flow Pump Impeller at Various Tip Clearances Using Three-Dimensional Viscous Flow Computations , 1992 .

[3]  D. F. Rogers,et al.  An Introduction to NURBS: With Historical Perspective , 2011 .

[4]  Don Olsen,et al.  Computational Fluid Dynamics (CFD) study of the 4th generation prototype of a continuous flow Ventricular Assist Device (VAD). , 2004, Journal of biomechanical engineering.

[5]  R. Opitz,et al.  A Couette viscometer for short time shearing of blood. , 1980, Biorheology.

[6]  J F Antaki,et al.  Microhaemodynamics within the blade tip clearance of a centrifugal turbodynamic blood pump , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[7]  H. Reul,et al.  Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves , 1990, The International journal of artificial organs.

[8]  C Bludszuweit,et al.  Model for a general mechanical blood damage prediction. , 1995, Artificial organs.

[9]  William R Wagner,et al.  Elimination of adverse leakage flow in a miniature pediatric centrifugal blood pump by computational fluid dynamics-based design optimization. , 2005, ASAIO journal.

[10]  A. Engeda,et al.  Comparisons of the relative effect of tip clearance on centrifugal impellers. , 1987 .

[11]  J. Crisp,et al.  An interdisciplinary approach to fracture and strength of solids , 1968 .

[12]  J F Antaki,et al.  A mathematical model for shear-induced hemolysis. , 1995, Artificial organs.

[13]  Kiyohito Tani,et al.  CFD-Based Design Optimization for Hydro Turbines , 2007 .

[14]  Alexey J. Stepanoff,et al.  Centrifugal and Axial Flow Pumps: Theory, Design, and Application , 1991 .

[15]  David Japikse,et al.  Centrifugal pump design and performance , 1997 .

[16]  Natalie L James,et al.  Evaluation of hemolysis in the VentrAssist implantable rotary blood pump. , 2003, Artificial organs.

[17]  J F Antaki,et al.  Computational flow optimization of rotary blood pump components. , 1995, Artificial organs.

[18]  P E Allaire,et al.  Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump. , 2000, Artificial organs.

[19]  Gill B Bearnson,et al.  HeartQuest ventricular assist device magnetically levitated centrifugal blood pump. , 2006, Artificial organs.

[20]  William R Wagner,et al.  Design optimization of blood shearing instrument by computational fluid dynamics. , 2005, Artificial organs.

[21]  Yukihiko Nosé,et al.  Centrifugal blood pumps for various clinical needs. , 2002, Artificial organs.

[22]  L P Chua,et al.  Numerical investigation of the effect of blade geometry on blood trauma in a centrifugal blood pump. , 2002, Artificial organs.

[23]  Ch. Hirsch,et al.  A Numerically Supported Investigation of the 3D Flow in Centrifugal Impellers: Part II — Secondary Flow Structure , 1996 .

[24]  R. Fåhraeus THE SUSPENSION STABILITY OF THE BLOOD , 1929 .