Reliability of maximal static strength measurements of the arms in subjects with hemiparesis

Objective: To evaluate the reliability of maximal static strength measurements of five arm muscle groups and of strength ratios (paretic/non-paretic) in subjects with poststroke hemiparesis. Design: The generalizability theory was used to estimate the reliability coefficients and standard errors of measurement of maximal strength for various combinations of trials and sessions and of the strength ratios for one and two sessions. Grip maximal voluntary force and/or maximal voluntary torques exerted by flexor and extensor muscles at both the elbow and shoulder joints were measured in 17 subjects with poststroke hemiparesis. Multiple trials were performed by subjects during two sessions. Setting: Rehabilitation centre. Subjects: A convenience sample of 17 subjects with poststroke hemiparesis. Results: The reliability coefficients for the strength measurements were in the range of 0.81-0.97 with standard errors of measurement accounting for 4% to 20% of the group means. For the strength ratios, the coefficients of generalizability ranged from 0.76 to 0.95 with standard errors of measurement equal to 6% to 19% of the group means. Conclusions: The maximal strength measurements of the arms in subjects with hemiparesis are reliable. The strength ratios are also reliable and can be used to quantify strength impairment.

[1]  J M Rothstein,et al.  Intrasession and intersession reliability of hand-held dynamometer measurements taken on brain-damaged patients. , 1989, Physical therapy.

[2]  F. Ferlazzo,et al.  G theory and the reliability of psychophysiological measures: a tutorial. , 2001, Psychophysiology.

[3]  J. Duchateau,et al.  Effect of time of day on force variation in a human muscle , 1999, Muscle & nerve.

[4]  K. An,et al.  Reliability of isometric strength testing. Temporal factors and strength variation. , 1984, Clinical orthopaedics and related research.

[5]  P. Stratford,et al.  Measuring Physical Impairment and Disability With the Chedoke‐McMaster Stroke Assessment , 1993, Stroke.

[6]  P. Tang,et al.  Test-retest reliability of isokinetic muscle strength of the lower extremities in patients with stroke. , 2002, Archives of physical medicine and rehabilitation.

[7]  J. Eng,et al.  Reliability of lower extremity strength measures in persons with chronic stroke. , 2002, Archives of physical medicine and rehabilitation.

[8]  B. Lindmark,et al.  Test-retest intra-rater reliability of grip force in patients with stroke. , 2003, Journal of rehabilitation medicine.

[9]  S. Perry,et al.  Stroke Rehabilitation: Guidelines for Exercise and Training to Optimize Motor Skill , 2004 .

[10]  Richard W. Bohannon,et al.  Interrater reliability of a modified Ashworth scale of muscle spasticity. , 1987, Physical therapy.

[11]  I Haslock,et al.  Visual analogue scales. , 1982, Annals of the rheumatic diseases.

[12]  Richard J. Shavelson,et al.  Generalizability Theory: A Primer , 1991 .

[13]  Factors Influencing Diurnal Variation of Strength of Grip , 1959 .

[14]  W. Kroll A Reliable Method of Assessing Isometric Strength , 1963 .

[15]  Ronald Melzack,et al.  Pain Measurement and Assessment , 1983 .

[16]  P. Duncan,et al.  Reliability of lower extremity isokinetic strength testing in adults with stroke , 2000, Clinical rehabilitation.

[17]  S. Folstein,et al.  "Mini-mental state". A practical method for grading the cognitive state of patients for the clinician. , 1975, Journal of psychiatric research.

[18]  A static dynamometer measuring simultaneous torques exerted at the upper limb. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[19]  L. Crocker,et al.  Introduction to Classical and Modern Test Theory , 1986 .

[20]  D. Gravel,et al.  Maximal grip force in chronic stroke subjects and its relationship to global upper extremity function , 1999, Clinical rehabilitation.

[21]  Comparison of strength measurements under single-joint and multi-joint conditions in hemiparetic individuals , 2005, Clinical rehabilitation.

[22]  A. Gift,et al.  Visual Analogue Scales: Measurement of Subjective Phenomena , 1989, Nursing research.

[23]  Thompson G. Robinson,et al.  National Clinical Guidelines for Stroke. , 2001 .

[24]  D. Nowak,et al.  Grip force control during object manipulation in cerebral stroke , 2003, Clinical Neurophysiology.

[25]  Reliability of Lower Extremity Strength Measurements Using the Belt-Resisted Method , 1998 .

[26]  P. Dijkstra,et al.  Variation in measurements of grip strength. A study in reflex sympathetic dystrophy patients. , 1998, Acta orthopaedica Scandinavica. Supplementum.

[27]  S. Harris,et al.  Test-retest reliability of isokinetic knee extension and flexion torque measurements in persons with spastic hemiparesis. , 1991, Physical therapy.