A non-free-space propagation x-ray phase contrast imaging method sensitive to phase effects in two directions simultaneously

We present an x-ray phase contrast imaging method based on coded apertures sensitive to phase effects in two directions simultaneously. To date, this is the only non-free-space propagation approach with this capability. Whereas the use of free-space propagation methods is limited to synchrotron radiation or microfocal x-ray sources, which impose severe limits in terms of practical applicability, coded-aperture based methods have been shown to provide synchrotronlike phase contrast enhancements with conventional x-ray sources. A two-directional sensitive method working with conventional sources could create a breakthrough in medical imaging, where two-directional sensitivity is often a mandatory requirement.

[1]  C. J. Kotre,et al.  Phase contrast enhancement of x-ray mammography: a design study. , 1999, Physics in medicine and biology.

[2]  A Olivo,et al.  Modelling of a novel x-ray phase contrast imaging technique based on coded apertures , 2007, Physics in medicine and biology.

[3]  A. Snigirev,et al.  On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .

[4]  A Olivo,et al.  Image formation principles in coded-aperture based x-ray phase contrast imaging , 2008, Physics in medicine and biology.

[5]  A. Clark,et al.  Optical and x-ray characterization of two novel CMOS image sensors , 2007, SPIE OPTO.

[6]  S. Wilkins,et al.  Phase-contrast imaging of weakly absorbing materials using hard X-rays , 1995, Nature.

[7]  Akira Furukawa,et al.  The First Trial of Phase Contrast Imaging for Digital Full-Field Mammography Using a Practical Molybdenum X-Ray Tube , 2005, Investigative radiology.

[8]  E. Pisano,et al.  Diffraction enhanced x-ray imaging. , 1997, Physics in medicine and biology.

[9]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[10]  E Castelli,et al.  Low-dose phase contrast x-ray medical imaging. , 1998, Physics in medicine and biology.

[11]  R. Speller,et al.  A coded-aperture technique allowing x-ray phase contrast imaging with conventional sources , 2007 .

[12]  A Olivo,et al.  Experimental validation of a simple model capable of predicting the phase contrast imaging capabilities of any x-ray imaging system , 2006, Physics in medicine and biology.

[13]  Robert D. Speller,et al.  First evidence of phase-contrast imaging with laboratory sources and active pixel sensors , 2007 .

[14]  Alessandro Olivo Towards the exploitation of phase effects in clinical synchrotron radiation radiology , 2005 .

[15]  F Arfelli,et al.  An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field. , 2001, Medical physics.

[16]  Atsushi Momose,et al.  Phase–contrast X–ray computed tomography for observing biological soft tissues , 1996, Nature Medicine.

[17]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[18]  R. Lewis,et al.  Medical phase contrast x-ray imaging: current status and future prospects. , 2004, Physics in medicine and biology.