The meaning of the turning point of the index of motor current amplitude curve in controlling a continuous flow pump or evaluation of left ventricular function.

In this series, we investigated the meaning of the t-point of index of motor current amplitude (ICA) curve from a point of view of flow rate on in vitro and in vivo studies. On mock circulation loop and left ventricular assist device (LVAD)-equipped pigs, we detected the t-point and compared the pump flow at the t-point with the simultaneous cardiac output. The pump flow at the t-point showed high correlation against the simultaneous cardiac output for in vitro or in vivo study. By detection of the t-point of the ICA curve and measuring or estimating the pump flow at t-point, the cardiac output may be assessed without any sensor in various cardiac conditions.

[1]  T Tsukiya,et al.  Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump. , 2008, Artificial organs.

[2]  T Takano,et al.  Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study. , 2000, Artificial organs.

[3]  K Araki,et al.  The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function. , 2001, Artificial organs.

[4]  D Kikugawa Evaluation of cardiac function during left ventricular assist by a centrifugal blood pump. , 2000, Artificial organs.

[5]  K Araki,et al.  Control strategy for biventricular assistance with mixed-flow pumps. , 2000, Artificial organs.

[6]  S Takatani,et al.  Control of centrifugal blood pump based on the motor current. , 1997, Artificial organs.

[7]  K Araki,et al.  Sensorless controlling method for a continuous flow left ventricular assist device. , 2000, Artificial organs.

[8]  K Araki,et al.  Detection of total assist and sucking points based on pulsatility of a continuous flow artificial heart: in vitro evaluation. , 1998, ASAIO journal.

[9]  J R Boston,et al.  Controller for an Axial Flow Blood Pump. , 1996, Artificial organs.

[10]  M Komeda,et al.  Physical model-based indirect measurements of blood pressure and flow using a centrifugal pump. , 2000, Artificial organs.

[11]  S Takatani,et al.  Detection of suction and regurgitation of the implantable centrifugal pump based on the motor current waveform analysis and its application to optimization of pump flow. , 1999, Artificial organs.

[12]  T Takano,et al.  Control system for an implantable rotary blood pump. , 2000, Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia.