Preclinical MR fingerprinting (MRF) at 7 T: effective quantitative imaging for rodent disease models

High‐field preclinical MRI scanners are now commonly used to quantitatively assess disease status and the efficacy of novel therapies in a wide variety of rodent models. Unfortunately, conventional MRI methods are highly susceptible to respiratory and cardiac motion artifacts resulting in potentially inaccurate and misleading data. We have developed an initial preclinical 7.0‐T MRI implementation of the highly novel MR fingerprinting (MRF) methodology which has been described previously for clinical imaging applications. The MRF technology combines a priori variation in the MRI acquisition parameters with dictionary‐based matching of acquired signal evolution profiles to simultaneously generate quantitative maps of T1 and T2 relaxation times and proton density. This preclinical MRF acquisition was constructed from a fast imaging with steady‐state free precession (FISP) MRI pulse sequence to acquire 600 MRF images with both evolving T1 and T2 weighting in approximately 30 min. This initial high‐field preclinical MRF investigation demonstrated reproducible and differentiated estimates of in vitro phantoms with different relaxation times. In vivo preclinical MRF results in mouse kidneys and brain tumor models demonstrated an inherent resistance to respiratory motion artifacts as well as sensitivity to known pathology. These results suggest that MRF methodology may offer the opportunity for the quantification of numerous MRI parameters for a wide variety of preclinical imaging applications. Copyright © 2015 John Wiley & Sons, Ltd.

[1]  C. Beaulieu,et al.  Comparison of diffusion-weighted MRI and CT in acute stroke , 2000, Neurology.

[2]  P Wach,et al.  Imaging of the active B1 field in vivo , 1996, Magnetic resonance in medicine.

[3]  R R Edelman,et al.  Pulmonary perfusion: Qualitative assessment with dynamic contrast‐enhanced MRI using ultra‐short TE and inversion recovery turbo FLASH , 1996, Magnetic resonance in medicine.

[4]  Peter C M van Zijl,et al.  MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST) , 2007, Proceedings of the National Academy of Sciences.

[5]  M. Griswold,et al.  Inversion recovery TrueFISP: Quantification of T1, T2, and spin density , 2004, Magnetic resonance in medicine.

[6]  R. Daffner,et al.  MRI in the detection of malignant infiltration of bone marrow. , 1986, AJR. American journal of roentgenology.

[7]  Garry E Gold,et al.  Musculoskeletal MRI at 3.0 T: initial clinical experience. , 2004, AJR. American journal of roentgenology.

[8]  J. Duerk,et al.  Magnetic Resonance Fingerprinting , 2013, Nature.

[9]  R. Henkelman,et al.  Magnetization transfer in MRI: a review , 2001, NMR in biomedicine.

[10]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[11]  Mariya Doneva,et al.  Compressed sensing reconstruction for magnetic resonance parameter mapping , 2010, Magnetic resonance in medicine.

[12]  P. Lundberg,et al.  Rapid magnetic resonance quantification on the brain: Optimization for clinical usage , 2008, Magnetic resonance in medicine.

[13]  M A Griswold,et al.  CEST‐FISP: A novel technique for rapid chemical exchange saturation transfer MRI at 7 T , 2011, Magnetic resonance in medicine.

[14]  Mark Griswold,et al.  Rapid T1 mapping of mouse myocardium with saturation recovery look‐locker method , 2010, Magnetic resonance in medicine.

[15]  Jimmy D Bell,et al.  In vivo measurements of T1 relaxation times in mouse brain associated with different modes of systemic administration of manganese chloride , 2005, Journal of magnetic resonance imaging : JMRI.

[16]  S. Ulmer,et al.  Analysis of mouse brain using a clinical 1.5 T scanner and a standard small loop surface coil , 2006, Brain Research.

[17]  Terence W Nixon,et al.  High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo , 2006, Magnetic resonance in medicine.

[18]  Maximilian F Reiser,et al.  Diffusion and perfusion of the kidney. , 2010, European journal of radiology.

[19]  X Golay,et al.  Non-invasive Measurement of Perfusion: a Critical Review of Arterial Spin Labelling Techniques , 2022 .

[20]  S. Frick,et al.  Compressed Sensing , 2014, Computer Vision, A Reference Guide.

[21]  Anthony H. Aletras,et al.  Detecting Acute Coronary Syndrome in the Emergency Department With Cardiac Magnetic Resonance Imaging , 2003, Circulation.

[22]  U. Klose,et al.  FAIR true‐FISP perfusion imaging of the kidneys , 2004, Magnetic resonance in medicine.

[23]  F. Wiesinger,et al.  B1 mapping by Bloch‐Siegert shift , 2010, Magnetic resonance in medicine.

[24]  Jeff H. Duyn,et al.  An adaptive filter for suppression of cardiac and respiratory noise in MRI time series data , 2006, NeuroImage.

[25]  Emeline J Ribot,et al.  3D TrueFISP imaging of mouse brain at 4.7T and 9.4T , 2008, Journal of magnetic resonance imaging : JMRI.

[26]  P L Carson,et al.  Motion artifacts in quantitative magnetic resonance imaging. , 1986, Magnetic resonance imaging.

[27]  Denis Le Bihan,et al.  Looking into the functional architecture of the brain with diffusion MRI , 2003, Nature Reviews Neuroscience.

[28]  Mark Griswold,et al.  Fast cardiac T1 mapping in mice using a model‐based compressed sensing method , 2012, Magnetic resonance in medicine.

[29]  S. Sussman,et al.  Hypointense renal cell carcinoma: MR imaging with pathologic correlation. , 1990, Radiology.

[30]  W. Hundley,et al.  Magnetic Resonance Imaging Determination of Cardiac Prognosis , 2002, Circulation.

[31]  H. D. de Koning,et al.  Efficacy of MRI and mammography for breast-cancer screening in women with a familial or genetic predisposition. , 2004, The New England journal of medicine.

[32]  A. Luciani,et al.  Liver Cirrhosis : Intravoxel Incoherent Motion MR Imaging — Pilot Study 1 , 2008 .

[33]  W Hacke,et al.  A standardized MRI stroke protocol: comparison with CT in hyperacute intracerebral hemorrhage. , 1999, Stroke.

[34]  G. Pike,et al.  Correction for B1 and B0 variations in quantitative T2 measurements using MRI , 2000, Magnetic resonance in medicine.

[35]  M. E. Moseley,et al.  MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain , 2014, NeuroImage.

[36]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[37]  Anant Madabhushi,et al.  Simultaneous segmentation of prostatic zones using Active Appearance Models with multiple coupled levelsets , 2013, Comput. Vis. Image Underst..

[38]  S. Schoenberg,et al.  Cardiac magnetic resonance perfusion imaging for the functional assessment of coronary artery disease: a comparison with coronary angiography and fractional flow reserve. , 2006, European heart journal.

[39]  David L Wilson,et al.  Novel cryo-imaging of the glioma tumor microenvironment reveals migration and dispersal pathways in vivid three-dimensional detail. , 2011, Cancer research.

[40]  G J Barker,et al.  Serial magnetization transfer imaging to characterize the early evolution of new MS lesions , 1998, Neurology.

[41]  Gil Navon,et al.  Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST) , 2008, Proceedings of the National Academy of Sciences.

[42]  C. Sotak,et al.  The role of diffusion tensor imaging in the evaluation of ischemic brain injury – a review , 2002, NMR in biomedicine.

[43]  R M Henkelman,et al.  Suppression of respiratory motion artifacts in magnetic resonance imaging. , 1986, Medical physics.

[44]  R S Balaban,et al.  A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). , 2000, Journal of magnetic resonance.

[45]  M Komiyama,et al.  MR imaging: possibility of tissue characterization of brain tumors using T1 and T2 values. , 1987, AJNR. American journal of neuroradiology.

[46]  Xin Yu,et al.  Arterial spin labeling‐fast imaging with steady‐state free precession (ASL‐FISP): a rapid and quantitative perfusion technique for high‐field MRI , 2014, NMR in biomedicine.

[47]  D G Nishimura,et al.  Linear combination steady‐state free precession MRI , 2000, Magnetic resonance in medicine.

[48]  David M Higgins,et al.  Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart , 2004, Magnetic resonance in medicine.

[49]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[50]  Vikas Gulani,et al.  Magnetic resonance fingerprinting ( MRF ) for rapid quantitative abdominal imaging , 2013 .

[51]  R. Mark Henkelman,et al.  Fast spin‐echo for multiple mouse magnetic resonance phenotyping , 2005, Magnetic resonance in medicine.

[52]  Paul Strauss,et al.  Magnetic Resonance Imaging Physical Principles And Sequence Design , 2016 .

[53]  Klaus Sartor,et al.  A Standardized MRI Stroke Protocol , 1999 .

[54]  Gregory R. Lee,et al.  Diffusion‐prepared fast imaging with steady‐state free precession (DP‐FISP): A rapid diffusion MRI technique at 7 T , 2012, Magnetic resonance in medicine.

[55]  M. Griswold,et al.  MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout , 2015, Magnetic resonance in medicine.