Modeling of biodynamic responses distributed at the fingers and the palm of the human hand-arm system.

The objective of this study is to develop analytical models for simulating driving-point biodynamic responses distributed at the fingers and palm of the hand under vibration along the forearm direction (z(h)-axis). Two different clamp-like model structures are formulated to analyze the distributed responses at the fingers-handle and palm-handle interfaces, as opposed to the single driving point invariably considered in the reported models. The parameters of the proposed four- and five degrees-of-freedom models are identified through minimization of an rms error function of the model and measured responses under different hand actions, namely, fingers pull, push only, grip only, and combined push and grip. The results show that the responses predicted from both models agree reasonably well with the measured data in terms of distributed as well total impedance magnitude and phase. The variations in the identified model parameters under different hand actions are further discussed in view of the biological system behavior. The proposed models are considered to serve as useful tools for design and assessment of vibration isolation methods, and for developing a hand-arm simulator for vibration analysis of power tools.

[1]  D. E. Welcome,et al.  An investigation on the relationship between grip, push and contact forces applied to a tool handle , 2004 .

[2]  Subhash Rakheja,et al.  a Comparison of Biodynamic Models of the Human HAND-ARM System for Applications to Hand-Held Power Tools , 2002 .

[3]  R G Dong,et al.  Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review. , 2001, Critical reviews in biomedical engineering.

[4]  Markus Stücker,et al.  Increased laser Doppler flow in skin tumors corresponds to elevated vessel density and reactive hyperemia , 2006, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[5]  S. Rakheja,et al.  Driving-point mechanical impedance of the human hand-arm system: synthesis and model development , 1995 .

[6]  D. E. Welcome,et al.  Contact pressure distribution at hand–handle interface: role of hand forces and handle size , 2005 .

[7]  Steve Kihlberg,et al.  Biodynamic response of the hand-arm system to vibration from an impact hammer and a grinder , 1995 .

[8]  John Z. Wu,et al.  Estimation of vibration power absorption density in human fingers. , 2005, Journal of biomechanical engineering.

[9]  Ren G Dong,et al.  Simultaneous determination of the nonlinear‐elastic properties of skin and subcutaneous tissue in unconfined compression tests , 2007, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[10]  M J Griffin,et al.  Foundations of hand-transmitted vibration standards. , 1994, Nagoya journal of medical science.

[11]  Marc Thomas,et al.  Development of a new frequency weighting filter for the asessment of grinder exposure to wrist-transmitted vibration , 1998 .

[12]  M. Ashby,et al.  Cellular solids: Structure & properties , 1988 .

[13]  R G Dong,et al.  Distribution of mechanical impedance at the fingers and the palm of the human hand. , 2005, Journal of biomechanics.