Extremum seeking control for efficient operation of hybrid ground source heat pump system

The Hybrid Ground Source Heat Pump (GSHP) systems combine the renewable geothermal energy and cooling tower for rejecting the cooling load, which is often adopted for high cooling demand. Model based control can be limited due to variations in ambient conditions, ground-loop heat exchanger (GHE) and equipment characteristics, cost and reliability of sensors. A self-optimizing control scheme is proposed for efficient operation of the hybrid GSHP based on Extremum Seeking Control (ESC), with feedback of the total power consumption and the control inputs of the relative flow rate of cooling tower and the water pump speed. The cooling capacity of the heat pump regulates the evaporator leaving water at 7 °C. A Modelica based dynamic simulation model is developed for a Hybrid GSHP system, with the vertical GHE model adopted from Modelica Buildings Library. The transient heat transfer is implemented with a finite volume method inside and outside the borehole. The proposed ESC scheme is evaluated under the scenarios of fixed cooling load, ramp change in the evaporator inlet water temperature, diurnal sinusoidal cycle of air wet-bulb temperature, and realistic ambient and cooling load condition. Simulation results show the proposed ESC strategy effectively achieves nearly optimal efficiency without the need for plant model.

[1]  Perry Y. Li,et al.  Efficient Operation of Air-Side Economizer Using Extremum Seeking Control , 2010 .

[2]  Hongxing Yang,et al.  Vertical-borehole ground-coupled heat pumps: A review of models and systems , 2010 .

[3]  J. D. Deerman Simulation of Vertical U-tube Ground-coupled Heat Pump Systems using the Cylindrical Heat Source Solution , 1991 .

[4]  Z. Fang,et al.  Efficiency of vertical geothermal heat exchangers in the ground source heat pump system , 2003 .

[5]  Andrew D. Chiasson,et al.  Optimal Sizing of Hybrid Ground-Source Heat Pump Systems That Use a Cooling Pond as a Supplemental Heat Rejecter— A System Simulation Approach , 2001 .

[6]  Stephen P. Kavanaugh,et al.  Ground Source Heat Pumps : Design of Geothermal Systems for Commercial and Institutional Buildings , 1997 .

[7]  Kartik B. Ariyur,et al.  Real-Time Optimization by Extremum-Seeking Control , 2003 .

[8]  Yaoyu Li,et al.  Multi-variable Extremum Seeking Control for Mini-split Air-conditioning System , 2014 .

[9]  Shengwei Wang,et al.  Performance analysis of hybrid ground source heat pump systems based on ANN predictive control , 2014 .

[10]  Mehmet Esen,et al.  Temperature distributions in pavement and bridge slabs heated by using vertical ground-source heat pump systems , 2013 .

[11]  Christopher R. Laughman,et al.  Extremum Seeking Control for Energy Optimization of Vapor Compression Systems , 2012 .

[12]  Miroslav Krstic,et al.  Stability of extremum seeking feedback for general nonlinear dynamic systems , 2000, Autom..

[13]  S. Maithel Energy Efficiency and Renewable Energy , 2008 .

[14]  Hiep V. Nguyen,et al.  A methodology and computerized approach for optimizing hybrid ground source heat pump system design , 2013 .

[15]  Yang Hongxing,et al.  Study on hybrid ground-coupled heat pump systems , 2008 .

[16]  Z. Fang,et al.  Heat transfer analysis of boreholes in vertical ground heat exchangers , 2003 .

[17]  Jeffrey D. Spitler,et al.  Comparative Study of Operating and Control Strategies for Hybrid Ground-Source Heat Pump Systems Using a Short Time Step Simulation Model , 2000 .

[18]  Wei Song,et al.  Energy saving and economic analyses of design heating load ratio of ground source heat pump with gas boiler as auxiliary heat source , 2011, 2011 International Conference on Electric Technology and Civil Engineering (ICETCE).

[19]  Andrew G. Alleyne,et al.  Optimal subcooling in vapor compression systems via extremum seeking control: Theory and experiments , 2014 .

[20]  Miroslav Krstic,et al.  Performance improvement and limitations in extremum seeking control , 2000 .

[21]  Andrew D. Chiasson,et al.  Optimization of the ground thermal response in hybrid geothermal heat pump systems , 2010 .

[22]  Maizura Mokhtar,et al.  Intelligent multi-agent system for building heat distribution control with combined gas boilers and ground source heat pump , 2013 .

[23]  Xiao Li,et al.  Dynamic modeling and self-optimizing operation of chilled water systems using extremum seeking control , 2013 .

[24]  Donal Finn,et al.  Generalised water flow rate control strategy for optimal part load operation of ground source heat pump systems , 2015 .

[25]  Mustafa Inalli,et al.  Artificial neural networks and adaptive neuro-fuzzy assessments for ground-coupled heat pump system , 2008 .

[26]  Mustafa Inalli,et al.  Predicting performance of a ground-source heat pump system using fuzzy weighted pre-processing-based ANFIS , 2008 .

[27]  Maoyu Zheng,et al.  Development of a numerical model for the simulation of vertical U-tube ground heat exchangers , 2009 .

[28]  Joseph R. Wrobel Predictive Model and Application of a Hybrid GSHP System for Space Conditioning, Water Heating and Deicing of a Seniors Independent Living Center , 2004 .

[29]  Mehmet Esen,et al.  Forecasting of a ground-coupled heat pump performance using neural networks with statistical data weighting pre-processing , 2008 .

[30]  Per Lundqvist,et al.  A descriptive and comparative analysis of three common control techniques for an on/off controlled Ground Source Heat Pump (GSHP) system , 2013 .

[31]  Mustafa Inalli,et al.  Modeling a ground-coupled heat pump system by a support vector machine , 2008 .

[32]  Mehmet Esen,et al.  Experimental investigation of using ground source heat pump system for snow melting on pavements and bridge decks , 2010 .

[33]  Mehmet Esen,et al.  Experimental evaluation of using various renewable energy sources for heating a greenhouse , 2013 .

[34]  Mario A. Rotea,et al.  Analysis of multivariable extremum seeking algorithms , 2000, Proceedings of the 2000 American Control Conference. ACC (IEEE Cat. No.00CH36334).

[35]  Jeffrey D. Spitler,et al.  A short time step response factor model for vertical ground loop heat exchangers , 1999 .