Sectoral variations of iridocorneal angle width and iris volume in Chinese Singaporeans: a swept-source optical coherence tomography study

PurposeTo assess variations in the iridocorneal angle width and iris volume in Chinese subjects using swept-source optical coherence tomography (SS-OCT).MethodsConsecutive subjects, aged 40–80 years, with no previous ophthalmic problems were recruited from a population-based study of Chinese Singaporeans. All subjects underwent 360° SS-OCT (SS-1000 CASIA, Tomey Corporation, Nagoya, Japan) angle imaging and gonioscopy in one randomly selected eye in the dark. For each eye, 16 frames (11.25° apart) were selected for analysis from 128 cross-sectional images, and measurements of the trabecular iris space area 750 μm from the scleral spur (TISA750) and iris volume were made for each image. The measurements from four consecutive frames were further averaged as a sector of 45°. Sector-wise angle width and quadrant-wise iris volume were analyzed.ResultsTwo hundred and twelve subjects (90 with closed-angles) were examined. The majority of the subjects were female (70.7 %) with mean age 61 (±8.9) years. The TISA750 (mm2) of superior [0.101 (0.09)], inferior [0.105 (0.09)], superior–nasal [0.111 (0.09)] and superior–temporal [0.117 (0.09)] sectors were smaller compared with other sectors (P < 0.05). The nasal iris volume (mm3) was the smallest compared with other quadrants for the entire cohort [nasal 8.18 (1.2) < inferior 9.13 (1.3) < temporal 9.16 (1.2) < superior 9.33 (1.3), P < 0.001], as well as for open- and closed-angle groups.ConclusionsThe irido-corneal angle was narrower in the superior, inferior, superior–nasal and superior–temporal sectors compared with other sectors. Iris volume in the nasal quadrant was the smallest compared with the other quadrants.

[1]  A. Iwase,et al.  Prevalence of appositional angle closure determined by ultrasonic biomicroscopy in eyes with shallow anterior chambers. , 2005, Ophthalmology.

[2]  C. Phillips,et al.  CLOSED-ANGLE GLAUCOMA SIGNIFICANCE OF SECTORAL VARIATIONS IN ANGLE DEPTH* , 1956, The British journal of ophthalmology.

[3]  S. Fudemberg Increased iris thickness and association with primary angle closure glaucoma , 2012 .

[4]  Tien Yin Wong,et al.  Novel association of smaller anterior chamber width with angle closure in Singaporeans. , 2010, Ophthalmology.

[5]  P. Mitchell,et al.  Methodology of the Singapore Indian Chinese Cohort (SICC) Eye Study: Quantifying ethnic variations in the epidemiology of eye diseases in Asians , 2009, Ophthalmic epidemiology.

[6]  Mingguang He,et al.  Anterior chamber angle assessment techniques. , 2008, Survey of ophthalmology.

[7]  Mingguang He,et al.  Gonioscopy in adult Chinese: the Liwan Eye Study. , 2006, Investigative ophthalmology & visual science.

[8]  R. Lowe,et al.  Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma. , 1970, The British journal of ophthalmology.

[9]  G. Johnson,et al.  The Burden of Trachoma in the Rural Nile Delta of Egypt : a Survey of Menofiya Governorate The Epidemiology of Ocular Trauma in Singapore : Perspective from the Emergency Service of a Large Tertiary Hospital , 2005 .

[10]  David Huang,et al.  Optical coherence tomography imaging of the anterior chamber angle. , 2005, Ophthalmology clinics of North America.

[11]  Tin Aung,et al.  Assessment of trabecular meshwork width using swept source optical coherence tomography , 2013, Graefe's Archive for Clinical and Experimental Ophthalmology.

[12]  M. F. Fuller,et al.  Practical Nonparametric Statistics; Nonparametric Statistical Inference , 1973 .

[13]  R. Ritch,et al.  Quantitative evaluation of anterior segment parameters in the era of imaging. , 2007, Transactions of the American Ophthalmological Society.

[14]  D. Friedman,et al.  Lens vault, thickness, and position in Chinese subjects with angle closure. , 2011, Ophthalmology.

[15]  F. Foster,et al.  Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. , 1992, American journal of ophthalmology.

[16]  Tin Aung,et al.  Swept source optical coherence tomography measurement of the iris–trabecular contact (ITC) index: a new parameter for angle closure , 2013, Graefe's Archive for Clinical and Experimental Ophthalmology.

[17]  Shu Liu,et al.  Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement. , 2011, Investigative ophthalmology & visual science.

[18]  R. Weinreb,et al.  Anterior chamber angle imaging with optical coherence tomography , 2011, Eye.

[19]  Christopher Kai-shun Leung,et al.  Novel approach for anterior chamber angle analysis: anterior chamber angle detection with edge measurement and identification algorithm (ACADEMIA). , 2006, Archives of ophthalmology.

[20]  J. Schuman Section 7 – Closed Angle Glaucoma , 2008 .

[21]  W. J. Conover,et al.  Practical Nonparametric Statistics , 1972 .

[22]  D. Friedman,et al.  Quantitative iris parameters and association with narrow angles. , 2010, Ophthalmology.

[23]  F. Foster,et al.  Clinical use of ultrasound biomicroscopy. , 1991, Ophthalmology.

[24]  D. Friedman,et al.  Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography , 2010, Journal of glaucoma.

[25]  J. S. Myers Anterior chamber angle imaging with optical coherence tomography , 2012 .

[26]  R. Pandey,et al.  Ultrasound Biomicroscopy in the Subtypes of Primary Angle Closure Glaucoma , 2005, Journal of glaucoma.

[27]  D. Friedman,et al.  Comparison of gonioscopy and anterior segment ocular coherence tomography in detecting angle closure in different quadrants of the anterior chamber angle. , 2008, Ophthalmology.

[28]  Seagig Asia Pacific Glaucoma Guidelines , 2003 .

[29]  Tin Aung,et al.  Assessment of circumferential angle-closure by the iris-trabecular contact index with swept-source optical coherence tomography. , 2013, Ophthalmology.

[30]  Joseph A Izatt,et al.  Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles. , 2005, Archives of ophthalmology.

[31]  Guihua Xu,et al.  Imaging the iris with swept-source optical coherence tomography: relationship between iris volume and primary angle closure. , 2013, Ophthalmology.