Initial stability of a new hybrid fixation hip stem: experimental measurement of implant-bone micromotion under torsional load in comparison with cemented and cementless stems.

A new hybrid fixation stem, named cemented-locked uncemented (CLU), for total hip arthroplasty was developed to achieve good initial stability. Primary stability is guaranteed by the cement which is injected into two pockets in the lateral area. This leaves a large surface available for long-term biologic fixation (direct bone attachment on implant). This study evaluates in vitro the initial stability of the CLU prototype under torsional load, in comparison with cemented and cementless stems. The results show that the CLU stem is very stable in simulated stair climbing. Its micromotions are comparable to those of a cemented prosthesis, and significantly less (80-90% lower) than those for a cementless stem. These findings confirm the optimal initial stability expected from the CLU prototype. This new design, which employs hybrid fixation, should improve bone formation on the implant and reduce the risk of stem loosening.

[1]  P G Niederer,et al.  Comparison of the stability of press‐fit hip prosthesis femoral stems using a synthetic model femur , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[2]  W. W. Daniel Applied Nonparametric Statistics , 1979 .

[3]  A. Shirazi-Adl,et al.  Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. , 1993, Journal of biomedical materials research.

[4]  A Shirazi-Adl,et al.  Analysis of cementless implants using interface nonlinear friction--experimental and finite element studies. , 1997, Journal of biomechanics.

[5]  H. Tullos,et al.  The anatomic basis of femoral component design. , 1988, Clinical orthopaedics and related research.

[6]  L. Whiteside,et al.  Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel. , 1993, The Journal of arthroplasty.

[7]  L. Whiteside,et al.  Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission. , 1989, Clinical orthopaedics and related research.

[8]  J J Callaghan,et al.  The effect of femoral stem geometry on interface motion in uncemented porous-coated total hip prostheses. Comparison of straight-stem and curved-stem designs. , 1992, The Journal of bone and joint surgery. American volume.

[9]  J. M. Lee,et al.  Observations on the Effect of Movement on Bone Ingrowth into Porous‐Surfaced Implants , 1986, Clinical orthopaedics and related research.

[10]  W. Maloney,et al.  In vitro study of initial stability of a conical collared femoral component. , 1992, The Journal of arthroplasty.

[11]  L Cristofolini,et al.  Initial stability of uncemented hip stems: an in-vitro protocol to measure torsional interface motion. , 1995, Medical engineering & physics.

[12]  C. Engh,et al.  Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components. , 1993, The Journal of arthroplasty.

[13]  A. Cappello,et al.  Mechanical validation of whole bone composite tibia models. , 2000, Journal of biomechanics.

[14]  J H Heegaard,et al.  Frictional interface micromotions and anisotropic stress distribution in a femoral total hip component. , 1993, Journal of biomechanics.

[15]  P S Walker,et al.  Strains and micromotions of press-fit femoral stem prostheses. , 1987, Journal of biomechanics.

[16]  S. Imura,et al.  Micromotions and Strains of Cementless Femoral Prostheses , 1992 .

[17]  D L Bartel,et al.  Coulomb frictional interfaces in modeling cemented total hip replacements: a more realistic model. , 1995, Journal of biomechanics.

[18]  L Cristofolini,et al.  Mechanical validation of whole bone composite femur models. , 1996, Journal of biomechanics.

[19]  C. Bünger,et al.  Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditions , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[20]  J. Hunter,et al.  Early femoral loosening in one design of cemented hip replacement. , 1997, The Journal of bone and joint surgery. British volume.

[21]  P. Ducheyne,et al.  Comparison of the inflammatory response to particulate polymethylmethacrylate debris with and without barium sulfate , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[22]  P C McLeod,et al.  Measurements of repetitive activities of the knee. , 1975, Journal of biomechanics.

[23]  P Herberts,et al.  Radiographic risk signs for loosening after cemented THA: 61 loose stems and 23 loose sockets compared with 42 controls. , 1996, Acta orthopaedica Scandinavica.

[24]  B. Mjöberg Theories of wear and loosening in hip prostheses. Wear-induced loosening vs loosening-induced wear--a review. , 1994, Acta orthopaedica Scandinavica.

[25]  L Cristofolini,et al.  A critical analysis of stress shielding evaluation of hip prostheses. , 1997, Critical reviews in biomedical engineering.

[26]  H. Rubash,et al.  In vivo and in vitro analysis of membranes from hip prostheses inserted without cement. , 1994, The Journal of bone and joint surgery. American volume.

[27]  C. Engh,et al.  Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty. , 1992, Clinical orthopaedics and related research.

[28]  W H Harris,et al.  Quantification of Implant Micromotion, Strain Shielding, and Bone Resorption With Porous‐Coated Anatomic Medullary Locking Femoral Prostheses , 1992, Clinical orthopaedics and related research.

[29]  N Verdonschot,et al.  The effects of cement-stem debonding in THA on the long-term failure probability of cement. , 1997, Journal of biomechanics.

[30]  K. Markolf,et al.  The effect of calcar contact on femoral component micromovement. A mechanical study. , 1980, The Journal of bone and joint surgery. American volume.

[31]  L. Whiteside,et al.  Failure of cementless fixation of the femoral component in total hip arthroplasty. , 1992, The Orthopedic clinics of North America.

[32]  R. Jinnah,et al.  Computerized templating in uncemented total hip arthroplasty to assess component fit and fill. , 1992, The Journal of arthroplasty.

[33]  D. Davy,et al.  Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[34]  W. Hayes,et al.  Cross-sectional geometry of Pecos Pueblo femora and tibiae--a biomechanical investigation: I. Method and general patterns of variation. , 1983, American journal of physical anthropology.

[35]  T. Glant,et al.  Response of three murine macrophage populations to particulate debris: Bone resorption in organ cultures , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[36]  M A Freeman,et al.  Torsional stability of the femoral component of hip arthroplasty. Response to an anteriorly applied load. , 1989, The Journal of bone and joint surgery. British volume.

[37]  A. Shirazi-Adl,et al.  Friction properties at the bone-metal interface: comparison of four different porous metal surfaces. , 1997, Journal of biomedical materials research.

[38]  T W Phillips,et al.  Femoral stem fixation in hip replacement. A biomechanical comparison of cementless and cemented prostheses. , 1990, The Journal of bone and joint surgery. British volume.

[39]  D. Baker,et al.  In vivo inflammatory response to polymethylmethacrylate particulate debris: Effect of size, morphology, and surface area , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.