Results of a 10‐year survey of workload for 10 treatment vaults at a high‐throughput comprehensive cancer center

&NA; The workload for shielding purposes of modern linear accelerators (linacs) consists of primary and scatter radiation which depends on the dose delivered to isocenter (cGy) and leakage radiation which depends on the monitor units (MUs). In this study, we report on the workload for 10 treatment vaults in terms of dose to isocenter (cGy), monitor units delivered (MUs), number of treatment sessions (Txs), as well as, use factors (U) and modulation factors (CI) for different treatment techniques. The survey was performed for the years between 2006 and 2015 and included 16 treatment machines which represent different generations of Varian linear accelerators (6EX, 600C, 2100C, 2100EX, and TrueBeam) operating at different electron and x‐ray energies (6, 9, 12, 16 and 20 MeV electrons and, 6 and 15 MV x‐rays). An institutional review board (IRB) approval was acquired to perform this study. Data regarding patient workload, dose to isocenter, number of monitor units delivered, beam energies, gantry angles, and treatment techniques were exported from an ARIA treatment management system (Varian Medical Systems, Palo Alto, Ca.) into Excel spreadsheets and data analysis was performed in Matlab. The average (± std‐dev) number of treatment sessions, dose to isocenter, and number of monitor units delivered per week per machine in 2006 was 119 ± 39 Txs, (300 ± 116) × 102 cGys, and (78 ± 28) × 103 MUs respectively. In contrast, the workload in 2015 was 112 ± 40 Txs, (337 ± 124) × 102 cGys, and (111 ± 46) × 103 MUs. 60% of the workload (cGy) was delivered using 6 MV and 30% using 15 MV while the remaining 10% was delivered using electron beams. The modulation factors (MU/cGy) for IMRT and VMAT were 5.0 (± 3.4) and 4.6 (± 1.6) respectively. Use factors using 90° gantry angle intervals were equally distributed (˜0.25) but varied considerably among different treatment techniques. The workload, in terms of dose to isocenter (cGy) and subsequently monitor units (MUs), has been steadily increasing over the past decade. This increase can be attributed to increased use of high dose hypo‐fractionated regimens (SBRT, SRS) and the increase in use of IMRT and VMAT, which require higher MUs per cGy as compared to more conventional treatment (3DCRT). Meanwhile, the patient workload in terms of treatment sessions per week remained relatively constant. The findings of this report show that variables used for shielding purposes still fall within the recommendation of NCRP Report 151.

[1]  J. Smathers,et al.  Book Review , 2006, Journal of Applied Clinical Medical Physics.

[2]  F. Lohr,et al.  Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.

[4]  Radhe Mohan,et al.  Treatment vault shielding for a flattening filter-free medical linear accelerator , 2009, Physics in medicine and biology.

[5]  P. King,et al.  Shielding Techniques For Radiation Oncology Facilities , 1998, IEEE Engineering in Medicine and Biology Magazine.

[6]  J. Kuo,et al.  The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targets. , 2012, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[7]  C. Clark,et al.  Volumetric modulated arc therapy: a review of current literature and clinical use in practice. , 2011, The British journal of radiology.

[8]  Luca Cozzi,et al.  A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  James E. Rodgers,et al.  Radiation therapy vault shielding calculational methods when IMRT and TBI procedures contribute , 2001, Journal of applied clinical medical physics.

[10]  D A Jaffray,et al.  A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets. , 1999, International journal of radiation oncology, biology, physics.

[11]  D Followill,et al.  Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy. , 1997, International journal of radiation oncology, biology, physics.

[12]  James G. Mechalakos,et al.  Results of a one year survey of output for linear accelerators using IMRT and non‐IMRT techniques , 2004, Journal of applied clinical medical physics.

[13]  M van Herk,et al.  Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  D. Rogers,et al.  AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. , 1999, Medical physics.

[15]  Dietmar Georg,et al.  Impact of a flattening filter free linear accelerator on structural shielding design. , 2014, Zeitschrift fur medizinische Physik.

[16]  James Mechalakos,et al.  Estimation of Shielding Factors for Linear Accelerators* , 2002, Health physics.

[17]  S Mutic,et al.  Room shielding for intensity-modulated radiation therapy treatment facilities. , 2001, International journal of radiation oncology, biology, physics.

[18]  Jan-Jakob Sonke,et al.  Quality assurance for image-guided radiation therapy utilizing CT-based technologies: a report of the AAPM TG-179. , 2012, Medical physics.

[19]  C. Coyle,et al.  A Practical Guide to Intensity – Modulated Radiation Therapy , 2003 .

[20]  Paul J Keall,et al.  A new formula for normal tissue complication probability (NTCP) as a function of equivalent uniform dose (EUD) , 2008, Physics in medicine and biology.

[21]  F. d'Errico NCRP Report 151 Structural shielding design and evaluation for megavoltage x-and gamma-ray radiotherapy facilities , 2006 .

[22]  Tanya Kairn,et al.  Correcting radiation survey data to account for increased leakage during intensity modulated radiotherapy treatments. , 2013, Medical physics.