Experimental behaviour of RACFST stub columns after exposed to high temperatures

Abstract The experimental studies on the behaviour of recycled aggregate concrete-filled steel tube (RACFST) stub columns after exposed to high temperatures are reported in this paper. Forty specimens, including 32 RACFST stub columns and 8 normal concrete-filled steel tube (CFST) stub columns as reference, were tested, and the failure pattern, load versus strain relation and ultimate strength of the specimens were presented and analysed. Five types of concrete were produced: one reference concrete with natural aggregates, two concrete mixes with recycled coarse aggregate (RCA) replacement ratios of 50% and 100%, and two concrete mixes with recycled fine aggregate (RFA) replacement ratios of 50% and 100%. The specimens were exposed to 300 °C, 600 °C and 800 °C for 3 h. The test results showed that, due to the existence of the recycled aggregates, the post-fire performance of RACFST stub columns was lower than the corresponding normal CFST specimens under the same maximum temperature suffered, and the RACFST specimens with RCA had a better behaviour than those with RFA under the same recycled aggregate replacement ratio.

[1]  Lin-Hai Han,et al.  Residual Strength of Concrete Filled RHS Stub Columns after Exposure to High Temperatures , 2002 .

[2]  Xin Wu,et al.  Concrete Shrinkage and Creep in Recycled Aggregate Concrete-Filled Steel Tubes , 2008 .

[3]  Y. Yang,et al.  Recycled aggregate concrete filled steel SHS beam-columns subjected to cyclic loading , 2009 .

[4]  Lin-Hai Han,et al.  Experimental behaviour of recycled aggregate concrete filled steel tubular columns , 2006 .

[5]  T. Hansen Recycling of Demolished Concrete and Masonry , 1992 .

[6]  Lin-Hai Han,et al.  Concrete filled steel tube stub columns under combined temperature and loading , 2010 .

[7]  Yong Chang Wang,et al.  Behaviour of Repaired Concrete Filled Steel Tubular Column to Steel Beam Joints after Exposure to Fire , 2010 .

[8]  Lin-Hai Han,et al.  Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fire , 2005 .

[9]  J. de Brito,et al.  Post-fire residual mechanical properties of concrete made with recycled concrete coarse aggregates , 2011 .

[10]  Brian Uy,et al.  Performance of CFST column to steel beam joints subjected to simulated fire including the cooling phase , 2010 .

[11]  Y. Yang,et al.  Behaviour of Recycled Aggregate Concrete-Filled Steel Tubular Columns under Long-Term Sustained Loads , 2011 .

[12]  Lin-Hai Han,et al.  Experimental Performance of Recycled Aggregate Concrete-Filled Circular Steel Tubular Columns Subjected to Cyclic Flexural Loadings , 2009 .

[13]  Lin-Hai Han,et al.  Compressive and flexural behaviour of recycled aggregate concrete filled steel tubes (RACFST) under short-term loadings , 2006 .